My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11114 EVERGREEN WAY PAPAS BAKERY 2021-11-03
>
Address Records
>
EVERGREEN WAY
>
11114
>
PAPAS BAKERY
>
11114 EVERGREEN WAY PAPAS BAKERY 2021-11-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2021 8:05:42 AM
Creation date
11/3/2021 8:05:19 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11114
Tenant Name
PAPAS BAKERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> • <br /> I. Makeup Air(508): 711/7)-- <br /> 1. Applicant shall provide makeup air approximately equal to the exhaust. CFM. <br /> 2. Makeup air system shall be electronically interlocked with the exhaust system, such that the makeup <br /> air system will operate when the exhaust system is in operation. Provide note on plan sheet no. <br /> 3. Makeup air shall be provided by a mechanical or gravity means of sufficient capacity. Windows and <br /> door openings shall not be used for the purpose of providing makeup air. <br /> Fan Motorized Damper <br /> Make and Model: H.P.: Recommended air velocity, 500 fpm <br /> Duct Area <br /> Static Pressure: in. at Requirement= /500= <br /> CFM CFM/500 fpm <br /> CFM ft.2 <br /> Duct Dimension <br /> Duct Dimension: ft.2 Requirement= <br /> area <br /> Eff. Damper <br /> Air Velocity = Opening X = <br /> =CFM/area / fpm p 9 ft.2 <br /> CFM area <br /> J. Duct Slope and Cleanout Access (506.3.7, 506.3.8, 506.3.9): / <br /> 1. Horizontal duct up to 75' long: Minimum Slope '/4 in./ft. Proposed: '1<�" in./ft.'M <br /> Horizontal duct more than 75' long: Minimum Slope 1 in./ft. Proposed: -/ in./ft. <br /> 2. Tight-fitting cleanout doors shall be provided Total Number Proposed: <br /> at every change in ductwork direction. (WAC506.3.9.1) <br /> 3. Refer to State amendments for vertical ducts. (WAC506.3.9.2) <br /> K. Duct Enclosure (506.3.11): <br /> 1. Ducts penetrating a ceiling, wall or floor shall be enclosed in a duct enclosure having fire rating per <br /> IBC 708.4 from the point of penetration to the outside air. A duct may only penetrate exterior <br /> walls at locations where unprotected openings are permitted by Table 705.8 of 2009 International <br /> Building Code. <br /> Type of Construction Min. Fire-Resistive Proposed Proposed Material <br /> Const. of Enclosure &Construction <br /> I F.R., II F.R. 2 hour Lf hr. pled .51072 <br /> II, III, IV, V 1 hour y hr. <br /> 2. Duct enclosures shall be separated from the duct by at least 6". (506.3.10) Proposed: in. <br /> 3. Duct enclosures shall be sealed around the duct at the point of penetration and vented to the exterior <br /> through a weather-protected opening. <br /> 4. Duct enclosures shall serve only one kitchen exhaust duct. (See multiple hood venting for <br /> exception.) <br /> 5. Tight-fitting hinged access door shall be provided at each cleanout. Access enclosure doors shall <br /> have a fire-resistance rating equal to the enclosure. An approved sign shall be placed on the access <br /> door. "ACCESS PANEL. DO NOT OBSTRUCT." <br /> 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.