9 <br />0 <br />Permit Corrections: 14 E Casino Road <br />June 6, 2019 <br />Page 4 of 5 <br />Sheet A2.3: Please refer to 10/A2.3 ADA Family Toilet Plan, which has been added to this <br />sheet, with clearance dimensions for the water closet, sink, and required turning circle. The <br />soap dispenser has been relocated. Please also see Interior Elevations 6/A2.3. <br />Miscellaneous: <br />14. Male and female water closets: <br />This comment has not been addressed. The original comment stated that the building <br />requires male and female water closets at the ratios of 1 per-125 and 1 per-65, <br />respectively, per IBC Table 2902.1. Based on an even number of male and female <br />occupants per Section 2902.1.1, the building requires a minimum of two male and three <br />female water closets. The response states that the restrooms are close to the number <br />required and that additional facilities should not be needed. Note that the ratios stated <br />above reflect the A-3 occupancy only. The building also includes B occupancies, which <br />require restroom facilities at ratios exceeding the requirements for the A-3 occupancy (i.e., <br />approximately four water closets and three lavatories for each sex). The minimum facilities <br />specified in the original comment shall be provided. See IBC Section 2902.1. <br />Please see the attached letter documenting the extent to which the proposed number of <br />toilet rooms and fixtures will adequately serve the project and its program. <br />15. No additional comment. <br />16. No additional comment. <br />17. Safety glazing & U-value of glazing in new door: <br />This comment has not been completely addressed. Elevation 4/A2.2 specifies to relocate <br />an existing exterior door with glazing to this location. The following comments shall be <br />addressed: <br />a. The glazing in the door and adjacent windows shall have safety glazing per IBC Sections <br />2406.4.1 and 2406.4.2. The existing glazing left of the door shall be replaced with safety <br />glazing. <br />b. The door shall have a maximum thermal rating of U=0.6 per WSEC-15 Table C402.4. <br />See WSEC Section C503.1. The note stating W=O. 6 or better" is not clear. The note shall <br />be revised to state "maximum of U=0.6." <br />Sheet A2.2: A note indicating new safety glazing with a maximum U-value of <br />0.38 Btu/h•ft2-'F has been added for the glazing adjacent to the proposed new exterior Door <br />115. The note for said door has been revised to read "maximum U-value of 0.60". <br />18. Attachment at new interior, non-structural partition walls: <br />This comment has not been completely addressed. Detail 10/A2.4 has been added in <br />response to the original comment, showing top and bottom interior wall connections. The <br />following comments shall be addressed: <br />a. The required nailing (i.e., number and size) between the top plate and the roof structural <br />framing shall be specified. Specify the nailing between the blocking and trusses. <br />b. The top plate connection shall connect directly to the roof structural framing (i.e, trusses <br />and blocking), and shall not connected through the ceiling GWB. The GWB is not required <br />to be continuous provided that the joint between 5/8-inch wall and ceiling GWB is sealed on <br />each side of the wall. <br />