My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
14 E CASINO RD CHILD STRIVE 2022-01-14
>
Address Records
>
E CASINO RD
>
14
>
CHILD STRIVE
>
14 E CASINO RD CHILD STRIVE 2022-01-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2022 7:28:44 AM
Creation date
11/9/2021 11:11:44 AM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
14
Tenant Name
CHILD STRIVE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Permit Corrections: 14 E Casino Road <br />June 6, 2019 <br />Page 3 of 5 <br />9. Exterior emergency lighting locations: <br />This comment has not been completely addressed. The original comment stated that the <br />exterior landings for doorways serving a space or area with an occupant load of 50 or more <br />shall be provided with emergency lighting. The lighting shall specify a minimum 90-minute <br />uninterrupted supply power per IBC Section 1008.3.4. Notes have been added to Sheet <br />T1.2 in response. However, this is not sufficient to indicate where the lighting must be <br />provided. Exterior lighting shall be specified at Doors 100, 108-1, and 108. See IBC <br />Sections 1008.3.2 Item 5 and 1010,1.6. <br />Sheet A2.1: Please see response to item 8 above. <br />Fire Protection: <br />10. No additional comment. <br />11. No additional comment. <br />Accessibility: <br />12. Full accessibility —sidewalk ramp: <br />This comment has not been completely addressed. The original comment stated that the <br />project shall provide accessibility improvements per IEBC Section 705.2. Documentation <br />showing the limited accessibility improvements satisfy Exception 1 shall be submitted for <br />review. Note the proposed project is not fully -accessible unless the existing sidewalk ramp <br />adjacent to the northeast accessible parking satisfies ICC A117.1-09. See IEBC Section <br />806.1. <br />Sheet Al. 1: A new 5'-6" long concrete ramp (to navigate the existing curb height of 5 %Z"), <br />with a maximum slope of 1:12, and maximum side -flare slopes of 1:12 is proposed at the <br />revised accessible parking space at the north east corner of existing Building D. The 1:12 <br />side -flare slopes are proposed to utilize the exception in [CC Al 17.1 406.7 Landings: "In <br />alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be <br />provided and shall not be steeper than 1:12." It is our sense that the requirements of IEBC <br />Sec. 705.2 are now met, and that documentation illustrating compliance with IEBC Sec. <br />705.2 Exception 1 is not needed. <br />13. Accessible bathroom: <br />This comment has not been completely addressed. The original comment addressed the <br />accessible Bathroom 113 on Sheet A2.1. The clearance around the water closet does not <br />appear to satisfy the minimum 60-inch dimension to the sink per ICC A117.1-09 Figure <br />604.3. The sink shall be shifted as needed and the clearance specified on the plans. Note <br />that other minimum clearances should be specified, including but not limited to: 56-inch <br />clearance from the back wall, 30-inch by 48-inch clearance for the sink, and the 60-inch <br />turn -around clearance. The soap dispenser is not permitted in the water closet clearance <br />and should be relocated to the opposite side of the sink. See IBC Section 1101.2.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.