Laserfiche WebLink
November 28, 2018 <br />Owner: Anthony Iazeolla <br />Job Address: 6223 Kenwood Drive <br />Plan Check No: C1809-005 <br />RE: Response Letter <br />Jeff, <br />Please review revisions to this file: <br />1. Provide updated General Residential Notes sheet. All code references shall reflect the <br />current adopted codes. <br />Response: After review, I couldn't identify any specific inconsistencies on Sheet A0. Please <br />identify any discrepancies or redline changes. <br />2. Show all handrails and guardrails on plans and Elevation Drawings. Drawings shall reflect <br />the intent and clearly define the design proposed. <br />Response: See revised Elevations and related details, note we added Sheet A3.0 for Porch <br />Section 1 <br />3. Provide ledger detail for deck attachment. Show connectors staggered top and bottom <br />and show minimum edge distance per figure R507.2.1(1). <br />Response: See Detail 31 Sheet A4.0 <br />4. Provide lateral connection at all decks per section R507 IRC. Provide detail of lateral <br />connection and show location of connector on floor plan. See Figure R507.2.3(1) and <br />R507.2.3(2) IRC <br />Response: See Detail 21Sheet A4, Please review Lower Floor Plan Sheet A2.0 for locations. <br />5. Provide section and/or details for exterior stair and deck construction, including guard <br />attachment and handrail size and placement. <br />Response: See Detail 1 Sheet A3.0 <br />6. All footings shall rest on undisturbed soil not less than 18" below the finished grade, <br />including those footings supporting decks and porches. <br />Response: Added this note to Foundation Plan Sheet A2.0 updated Detail 4/Sheet a5.0 <br />DEC o 4 2018 <br />Permit Services <br />