My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5505 OCEAN AVE 2022-02-24
>
Address Records
>
OCEAN AVE
>
5505
>
5505 OCEAN AVE 2022-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 4:05:50 PM
Creation date
11/9/2021 2:53:15 PM
Metadata
Fields
Template:
Address Document
Street Name
OCEAN AVE
Street Number
5505
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Calvin Vander Veen <br />Vander Veen Construction <br />Plan Check Number: B1908-021, First Structural Review <br />November 1, 2019 <br />17. The shear wall design on structural calculation pages 14 through 16 appear to be based on the <br />design capacities per AWC SDPWS-15 Table 4.3A. The listed capacities are based on panels <br />fastened to douglas-fir-larch framing or better per Footnote 3. The "Dimensional Lumber" Note <br />2 in the General Notes on Sheet S-0 specifies wall framing as hem -fir. The shear wall capacities <br />shall be reduced and the wall design revised as needed. See IBC Section 2307.1. <br />18. Detail 9/S-2 shows a section through the new shear wall between the new and existing <br />structures. The shear wall will attract load from the existing structure and shall therefore be <br />extended to the existing roof line. See IBC Sections 1603.1 and 1604.4. <br />19. The structural calculations do not include a design for the diaphragms. Calculations <br />substantiating the diaphragm design shall be submitted for review. See IBC Sections 1604.1 <br />and 2307.1, and AWC SDPWS-15 Section 4.2. <br />20. Section 6/S-2 shows a step in the floor sheathing, interrupting the load path between the <br />sheathing and the shear wall. The detail shall be revised to complete the load path. <br />Alternatively, calculations substantiating the load path shall be submitted for review. See IBC <br />Sections 1604.1 and 1604.4. <br />21. The wood shear walls on the north exterior wall do not appear to include holdowns at the ends <br />to provide overturning resistance. Holdowns shall be provided connecting the boundary <br />elements (i.e., studs at the wall ends) to the foundation. Calculations substantiating the design <br />of the holdowns and boundary elements shall be submitted for review. See IBC Sections <br />1604.1, 1604.8.1, 1604.10, and 2307.1, and NDS-15 SDPWS Sections 3.4, 4.1.4, and 4.3.6.4.2. <br />See also IBC Section 1901.2, and ACI 318-14 Sections 17.2.3.4.3 and 17.2.3.3. <br />22. The shear wall holdown design has not been provided in the structural calculations. The <br />earthquake component of the uplift forces exceeds 20% of the total uplift (i.e., the earthquake <br />force is 100% of uplift force). The earthquake component shall be increased per the provisions <br />of ACI 318-14 Section 17.2.3.4.3. In addition, the anchorage utilizies post -installed anchors <br />and shall satisfy the provisions of Section 17.2.3.33. Calculations substantiating the holdown <br />design shall be submitted for review. The design load shall be determined per ASCE 7-10 <br />Section 12.4.3.2 Equation 7 including the vertical seismic load effect per Section 12.4.2.2. Due <br />to the structure having non -flexible diaphragms, the overstrength factor "0" shall not be <br />reduced by 1/2 per ASCE 7-10 Table 12.2-1 Footnote (g). The seismic holdown forces shall be <br />calculated even when wind controls the lateral design. See IBC Sections 1604.10, 1613.1, and <br />1901.2. <br />23. The design for the shear wall sill plate anchor bolts has not been provided in the structural <br />calculations. The earthquake component of the shear forces exceeds 20% of the total shear <br />(i.e., the earthquake force is 100% of shear force). The earthquake component shall be <br />increased per the provisions of ACI 318-14 Section 17.2.3.5.3. In addition, the anchorage <br />utilizies post -installed anchors and shall satisfy the provisions of Section 17.2.3.3. Calculations <br />substantiating the anchor bolt design shall be submitted for review. The design load shall be <br />determined per ASCE 7-10 Section 12.4.3.2 Equation 7. Due to the structure having non - <br />flexible diaphragms, the overstrength factor"n" shall not be reduced by 1/2 per ASCE 7-10 <br />5 3200 Cedar Street 425.257.8810 everetteps@everettwa.gov <br />Everett, WA 98201 425.257.8857 fax everettwa.gov/permi <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.