BUILDING ENCLOSURE DETAILS GENERAL NOTES: <br />O1 ALL METAL HEAD FLASHING TO BE MINIMUM 26 GAGE AND HAVE A STANDARD 4" HIGH FLANGE, <br />WITH 1" MIN. LONG HEMMED VERTICAL EDGE. SEE 4/BE-4 FOR FLASHING PROFILE. NOTE: HOLD <br />DRIP EDGE 1/8" OFF FACE OF EXTERIOR FINISH AT INSTALLATION. <br />O2 SLOPE TOP OF TRIM AS REQUIRED WHERE DRIP IS NOT PRESENT. <br />O3 RECOMMENDED BUILDING PAPER TO BE GRADE "D"60-MIN PAPER WITH MIN. 6" HORIZONTAL LAP, <br />AND 12" VERTICAL LAPS, MINIMUM 18" WRAP AROUND OUTSIDE AND INSIDE CORNERS. <br />O4 BITUTHENE ON FOUNDATION WALL TO BE RATED:EXAMPLE:BITUTHEN 3000 WITH PRIMER -BY WR <br />GRACE -AND APPROVED PROTECTION BOARD. <br />O6 ALL WOOD TRIM INCLUDING WALLS, BALCONIES, ROOFS MUST BE PRIMED. ALL CUT SURFACES MUST <br />BE REPRIMED BEFORE INSTALLATION. <br />OROUGH OPENING FOR WINDOWS AND DOORS TO BE PER MANUFACTURERS DIMENSIONS PLUS (+) <br />1/4". MAINTAIN CONTINUOUS 1/4" GAP AROUND DOOR AND WINDOWS OPENING FOR SHIM AND <br />SEALANT JOINT. <br />OMAINTAIN SEALANT JOINT DEPTH TO WIDTH RATIO AS RECOMMENDED PER SEALANT MANUFACTURER. <br />SEALANT JOINTS TO BE TOOLED. <br />O INSTALL BUILDING SIDING PER MANUFACTURE SPECS. <br />O9 CAULK ALL SEAMS, JOINTS AND CORNERS OF FLASHING. <br />10 SHEET SERIES IN THE DRAWING SET REFERS TO WATER INFILTRATION DETAILS. CONSTRUCTION DETAILS <br />ARE REFERENCED SEPERATELY IN THE DRAWING SET. THEREFORE ANY OVERLAP OF CONSTRUCTION <br />DETAILS SHOWN HEREIN IS INCIDENTAL AND IS INTENDED TO SHOW BUILDING ENCLOSURE DETAILS IN <br />THE OVERALL CONTEXT. <br />INSTALL WINDOW. <br />SECURE WINDOW BY JAMB NAIL FLANGE, SIDE <br />AND BOTTOM PER AAMA 2400-02. <br />IF R.O. IS NOT CORRECT DO NOT INSTALL <br />WINDOW. <br />0 STEP 4 <br />APPLY 6" STRIPS SBS MODIFIED <br />SELF-ADHESIVE, BITUTHENE WATER -PROOFING <br />AT ANY TWO ADJOINING JAMB NAILING FLANGE <br />ADJACENT TO EACH OTHER (INTERIOR <br />MULLIONS). <br />STEP 8 <br />CV <br />INSTALL 9" WIDE REINFORCED NONADHESIVE EQUAL <br />TO MOISTOP NEXT. BY FORTIFIBER AT SILL <br />EXTEND FORTIFIBER FLEXIBLE FLASHING 9" PAST <br />ROUGH OPENING ® EACH SIDE. <br />FASTEN ALONG TOP EDGE ONLY UNDER ROUGH <br />OPENING. <br />LEAVE 12" MIN. LOOSE ® EACH END TO ALLOW <br />GRADE "D" 60 MIN. PAPER TO BE TUCKED <br />UNDERNEATH FORTIFIBER FLEXIBLE FLASHING <br />0 STEP 5. <br />APPLY 9" STRIP SBS MODIFIED SELF-ADHESIVE, FLASHING <br />WATER -PROOFING OVER SHEET. MTL. FLASHING AT HEAD TO <br />SHEATHING. <br />HEAD FLASHING PER DETAIL 4/BE.4 <br />EXTEND FLASHING 9" MIN. PAST WINDOW JAMB 0 EACH SIDE. <br />99 11 <br />0 STEP 5 <br />APPLY 6" STRIPS SBS MODIFIED SELF-ADHESVE, FLASHING <br />WATER -PROOFING TO JAMB NAIL FLANGE AND OVER GRADE <br />"D" 60 MIN. PAPER AT WINDOW JAMBS. <br />BITUTHENE SHALL BE APPLIED TO EXPOSED JAMB NAIL <br />FLANGE AND LAP ONTO GRADE "D" 60 MIN. PAPER. <br />BITUTHENE SHALL BE APPLIED 4" MIN. ABOVE WINDOW UNIT <br />AND EXTEND 12" MIN. BELOW WINDOW UNIT. <br />�l,I <br />906 <br />ea <br />!6 <br />9! <br />�go0 <br />00, go <br />ean, <br />, <br />0 STEP 9 <br />0 STEP 1 <br />0 <br />INSTALL 9" WIDE FORTOFIBER FLEXIBLE FLASHING AT JAMBS. <br />3. FOLD FLEXIBLE <br />START 6" MIN. ABOVE ROUGH OPENING AND EXTEND 12" PAST <br />FLASHING <br />ROUGH OPENING LAPPING OVER FLEXIBLE FLASHING® SILL. <br />(POLYETHYLENE) <br />INSTALLED IN STEP 2 <br />FASTEN ENTIRELY ALONG BOTH EDGES. <br />AGAINST FACE OF <br />BUILDING. <br />LEAVE 9" MIN. LOOSE ® BOTTOM (DO NOT REMOVE BACKING) TO <br />ALLOW GRADE "D" 60 MIN. PAPER TO BE TUCKED UNDERNEATH <br />NOTE*-:BEIC DOES NOT <br />FORTIFIBER FLASHING 0 STEP 5. <br />RECOMMEND, RATHER <br />ELIMINATE STEP2 <br />(D STEP 2 <br />SHINGLE GRADE "D" 60 MIN. PAPER FROM BOTTOM <br />TO TOP. <br />GRADE "D" 60 MIN. PAPER COURSE AT BOTTOM OF <br />THE WINDOW UNIT, START BY CUTTING GRADE "D" <br />60 MIN. PAPER AND TUCK UNDERNEATH THE <br />REINFORCED VAPOR BARRIER & WINDOW UNIT <br />LAPPING PAPER UP SIDES MIN. 4" UNDER ROUGH <br />OPENEING FLEXIBLE FLASHING. <br />STEP 6 <br />INSTALL SHEET MTL. FLASHING AT HEAD OVER TRIM BOARD. <br />FLASHING SHALL HAVE 4" MIN. UPTURNED LEG AND SHALL EXTEND 1/2" <br />BEYOND JAMB OF WINDOW FRAME EACH SIDE.SEE DETAIL 5/BE.4 <br />METAL FLASHING SHALL BE CONTINUOUS OVER GROUPED WINDOWS. <br />10 STEP 10 <br />WINDOW WATERPROOFING WITH CONCEALED FLASHING DETAILS <br />SCALE: NTS <br />9" <br />f Ir <br />R•] <br />0 STEP 3 <br />NEXT HORIZONTAL GRADE "D" 60 MIN. PAPER COURSE <br />LAP DOWN PER SPECS. OVER PREVIOUS GRADE "D" 60 <br />MIN. PAPER, FLEXIBLE FLASHING AND WINDOW UNIT. <br />LAP GRADE "D" 60 MIN. PAPER ONTO JAMB, NAIL <br />FLANGE 1/2 LEAVING THE JAMB NAILING FLANGE <br />EXPOSED FOR ATTACHMENT OF SBS MODIFIED <br />SELF-ADHESIVE, FLASHING WATERPROOFING <br />WINDOW <br />UNIT- GRADE "D" 60 <br />MIN. PAPER <br />. �, _--JAMB NAIL <br />FLANGE <br />. <br />R H RO .H <br />NG ... • .. 'OP IN <br />2" <br />d- <br />Q STEP 7 <br />CONTINUE SHINGLING GRADE "D" 60 MIN. PAPER OVER HEAD <br />FLASHING, SBS MODIFIED SELF-ADHESIVE, FLASHING <br />WATER -PROOFING AND UP THE SIDE OF THE BUILDING. <br />11 STEP 11 <br />NOTE: (2) LAYERS GRADE "D" <br />60 MIN. BUILDING PAPER SHALL <br />BE APPLIED TO BUILDING FIELD. <br />FIRST LAYER SHALL EXTEND <br />AROUND ROUGH OPENING & <br />UNDER WINDOW WRAP AT SILL <br />& JAMB & OVER HEAD <br />FLASHING. SECOND LAYER <br />SHALL EXTEND UNDER WINDOW <br />WRAP AT SILL AND OVER <br />WINDOW WRAP AT JAMBS & <br />OVER HEAD FLASHING. LAP <br />ALL BUILDING PAPER JOINTS <br />PER STEP #1. <br />14632 - 14th Ave. SE <br />Mill Creek, WA 98012 <br />(425)512-1780 <br />dwudesign@gmaii.corr <br />SHEET TITLE: <br />WATER <br />PROTECTION <br />DETAIL <br />PROJECT: <br />LUBWAMA <br />RESIDENCE <br />ADU <br />LOCATION: <br />1218 59th PLACE SW <br />EVERETT, WA 98203 <br />FILE: 2020-018 <br />DATE: 04/17/2020 <br />PREPARED BY: D. Wu <br />REVISIONS: <br />SHEET NUMBER: <br />A-5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.