0 c0 <br /> '-yStructural 1)csign .:\ssociates <br /> �` ¢ i ngiiicerfii S�irticlttres to Lasi <br /> cfy0. <br /> XL)A 9003 <br /> July g, 2020 i <br /> � t) <br /> ll 61'7 .7' . 'i 7 <br /> Attn: James Bronder, PE, SE it' , <br /> Subject Address: 1514 Grand Ave. Everett, WA JUL 7 <br /> Subject: Building Official Comments for Plan Check No: B2003-032C/T 2020 <br /> SDA Job No. 9003 OF <br /> r—ermit S VERETT <br /> To whom this may concern: �rV l ces <br /> At the request of Barney Petersen, this office has designed the structural aspects of the deck and deck <br /> canopy. The original project engineer. Danny R. Parrent, PE was notified of our involvement with the <br /> project. This letter shall be accompanied with the issued plans and calculation package. <br /> The building official comments were reviewed prior to engineering the project. The following is our <br /> response to those comments: <br /> Structural <br /> 1. Residential deck loading was used for the lateral,gravity, and foundation design. The loading is <br /> reported on S 1.0 of the plans and page 2 of the structural calculations. <br /> 2. Cantilever timber posts were used to resist lateral loads. A seismic response value of 1.25 was <br /> used. See calculation page 5. Combined normal and shear stresses were considered in the post <br /> design. See calculation pages 17-20. <br /> 3. The deck framing was designed with consideration of lateral and gravity loading. A hot tub will <br /> not be used on the deck. Verbiage clarifying the hot tub loading is provided on drawing S 1.3, <br /> 'Note#3'. <br /> 4. The deck framing was designed with consideration of lateral and gravity loading. A hot tub will <br /> not be used on the deck. Verbiage clarifying the hot tub loading is provided on drawing S 1.3, <br /> 'Note#3'. <br /> 5. Deck canopy framing provided on S 1.3. Rafters to be spaced at 24"on center. <br /> 6. Comment not applicable with submittal from Structural Design Associates, <br /> 7. The deck is designed to be self-supported. A seismic separation gap is specified on the plans. The <br /> design is intended to not transfer loads to the existing house. Refer to S 1.2-S 1.3 for seismic <br /> separation gap specification. <br /> 8. See detail 1/S5.0 for guard post connection and calculations. <br /> 9. A redundancy factor, rho of 1,3, is applied to the seismic loads applied to the cantilevered timber <br /> posts. See calculation pages 2-3. <br /> Please contact this office if you have any questions regarding this letter. <br /> Sincerely, . COVI , r`., <br /> ( c.,„)._1...----Th <br /> A. A' ,AnIll'Ai 1,j7 , , /..-...„„j <br /> , fr <br /> „..,,,,..-Attl' k, — !•4-, — - , r <br /> . .41. -. ,1" 4:. _.- - A 2 <br /> Jasper Baarbe. E.1.T. \A, 83 r Chris Coviungton P.E. <br /> R ' <br /> Structur, r ,;. 1 so€iates <br /> 3006 Rucker Ave. Everett. WA 98201 <br /> Ph: 425-339-0293 Fax: 425-252-0916 sdacverctt.com <br /> JUL 0 9 2020 <br />