My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2821 HEWITT AVE NW PLUS CREDIT UNION 2021-11-12
>
Address Records
>
HEWITT AVE
>
2821
>
NW PLUS CREDIT UNION
>
2821 HEWITT AVE NW PLUS CREDIT UNION 2021-11-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2021 2:34:29 PM
Creation date
11/12/2021 2:34:14 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2821
Tenant Name
NW PLUS CREDIT UNION
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
March 16th, 2021 <br /> E.., <br /> Richard Smith <br /> richard@newlandcompany.com MAR ' 2021 <br /> Newland Construction Co., Inc. CITY OF EV <br /> 3300 Chestnut St Permit ServR esT <br /> Everett,WA 98201 <br /> Owner: NW Plus Credit Union <br /> Job Address: 2821 Hewitt Ave <br /> Everett,WA 98201 <br /> RE: Comment Response Letter <br /> Plan Check No: PW2012-025 <br /> Dear James Bronder: <br /> Please see below for the correction called out after review for Plan Check Number PW2012-025: <br /> 1. The proposed location of an above-ground propane tank of 120 gallons does not appear to meet <br /> the minimum clearance requirements between the building nor is it clear on the plans if the <br /> proposed location is meeting the minimum clearances between the lot lines and public ways. <br /> Per IFC Table 6104.3, a minimum of 5'-0" is required. Please demonstrate on the plans that the <br /> tank is meeting these requirements and revise plans as required. IFC 6104.3. <br /> Per IFC 6104.3. E The following shall apply to above-ground containers installed alongside buildings: <br /> 1. LP-gas containers of less than a 125-gallon water capacity are allowed next to the building <br /> they serve where in compliance with Items 2,3 and 4. <br /> 2. Department of Transportation (DOTn)specification LP-gas containers shall be located and <br /> installed so that the discharge from the container pressure relief device is not less than 3 <br /> feet horizontally from building openings below the level of such discharge and shall not be <br /> beneath buildings unless the space is well ventilated to the outside and is not enclosed for <br /> more than 50 percent of its perimeter.The discharge from LP-gas container pressure relief <br /> devices shall be located not less than 5 feet from exterior sources of ignition,openings <br /> into direct-vent(sealed combustion system)appliances or mechanical ventilation air <br /> intakes. <br /> 3. ASME LP-gas containers of less than a 125-gallon water capacity shall be located and <br /> installed such that the discharge from pressure relief devices shall not terminate in or <br /> beneath buildings and shall be located not less than 5 feet horizontally from building <br /> openings below the level of such discharge and not less than 5 feet from exterior sources <br /> ' Iz <br />
The URL can be used to link to this page
Your browser does not support the video tag.