Laserfiche WebLink
2015 Washington State Encode Compliance Forms for Commercial,R2 and R3 over ries and all R1-Page 6 of 22 <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: ESD-ATHLETICSBUILDING Date 5/28/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes no.nal Documents Notes <br /> NA C406.2.2 Minimum equipment To comply with additional efficiency package option,indicate that all listed heating and cooling <br /> C403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br /> C406.2.3 To comply with additional efficiency package option,indicate rated FEG of stand alone fans is z <br /> NA C403.2.11.3 Minimum fan efficiency 71;indicate these fans are sized so the fan efficiency at design conditions is within 10%of the <br /> maximum total nr static efficiency <br /> HVAC System Controls <br /> Indicate locations of thermostatic and humidity control devices and the zones they serve on M0.2,0.3 <br /> plans,including perimeter system zones <br /> Where adjacent(neighboring)zones are controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or loss),and are connected by permanent openings <br /> Thermostatic controls >10%of either zone sf area,indicate controls configured to prevent adjacent zones from <br /> Yes C403.2.4.1 (thermostats and operating in conflicting modes(one in heat,other in cool);applies to adjacent perimeter zones, <br /> • humidistats) disc.rlf n nerirpetar Tunas ertd adiecant nari ¢ter and nonoerimeter 7npa <br /> app�ying xception 2 to nonpermeter zones adjacent to perimeter zones,--cote that <br /> setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter <br /> zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br /> nerimeter 7nne temperature in heatinn <br /> NA C403.2.4.1.1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and <br /> heat supplemental heating controlled with outdoor lock-out temperature set to 40°F or less <br /> Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that M0.2,0.3 <br /> control both heating and cooling <br /> If separate heating and cooling systems with separate thermostatic control devices are used to <br /> Setpoint overlap restriction serve a zone,indicate locations of both thermostatic control devices and the zone they serve <br /> Yes C403.2.4.1.3 (thermostats) on plans <br /> Indicate a limit switch,mechanical stop or DDC control with programming to prevent M0.2,0.3 <br /> simultaneous heating and cooling <br /> C403.2.4.2 Indicate zone thermostatic controls configured with required automatic setback and manual M0.2,0.3 <br /> Yes C403.2.4.2.1 Automatic setback and override functions,setback temperatures,and control method(automatic time clock or <br /> C403.2.4.2.2 shutdown nroarammable controls):note exceptions taken <br /> Yes C403.2.4.2.3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served up M0.2,0.3 <br /> to design temperature iust prior to scheduled occupancy <br /> NA C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment <br /> operation;not including economizer cooling,night flush or IMC required OSA/exhaust <br /> NA C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of <br /> dampers power) <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> NA C403.2.4.4 Zone isolation controls are expected to be occupied non-simultaneously;indicate controls that allow for independent <br /> space conditionina of isolation zones:or exception taken <br /> NA C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating <br /> system when area served is unoccupied <br /> NA C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature <br /> exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40°F <br /> Yes C403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or M0.2,0.3 <br /> controls conditions protect fluid from freezing <br /> Group Rt hotel/motel For hotels and motels with over 50 guest rooms,indicate automatic controls serving guest <br /> NA C403.2.4.9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at <br /> least 5°F:indicate control method-activated by room entry or occupancy sensor <br />