My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3721 OAKES AVE EVERETT SCHOOL DISTRICT 2021-11-15
>
Address Records
>
OAKES AVE
>
3721
>
EVERETT SCHOOL DISTRICT
>
3721 OAKES AVE EVERETT SCHOOL DISTRICT 2021-11-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2021 1:49:03 PM
Creation date
11/15/2021 1:48:20 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3721
Tenant Name
EVERETT SCHOOL DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Ene ode Compliance Forms for Commercial,R2 and R3 over 3• ries and all R1-Page 7 of 22 <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: ESD-ATHLETICSBUILDING Date 5/28/2020 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (ves.no.nal Documents Notes <br /> C403.2.4.10 Group R2/R3 dwelling For primary space conditioning system,indicate 5-2 programmable thermostats capable of two <br /> NA units,Group R2 sleeping setback periods per day;for all thermostats indicate purpose(heating only,cooling only,or <br /> C403.2.4.11 units both).required temperature ranae and at minimum a 10°F deadband:or exception taken <br /> Indicate <br /> method of ventilation air delivery(natural or mechanical)for each zone M-0.2,M1.4 <br /> C403.2.6 f mechanically delivered,indicate that systems are configured to provide not more than 150% Heat Load <br /> Yes C403.2.11.4 Ventilation f,but at least the minimum required volume of outdoor air to each zone per IMC,ASHRAE Calculation <br /> 2.1 or otherlicable code(WAC.OSHA,etc);or exception taken <br /> f delivered via natural ventilation,identify required elements per!MC including minimum <br /> penable area to the outdoors or qualifying adjjoining spaces <br /> dentity spaces>b00 st with occupant load>25 people/1,000 sf per IMt.;for each space <br /> Demand controlled indicate whether it is served by an HVAC system with total design OSA>3,000 cfm,and/or <br /> NA C403.2.6.2 ventilation the system has airside economizer or automatic modulating OSA damper;indicate OSA <br /> controls are configured to provide demand controlled ventilation or provide supporting <br /> nrumantatinn fnr annlied excentinn <br /> For gyms,classrooms,auditoriums and conference rooms>500 sf,indicate occupancy-based <br /> NA C403.2.6.3 Occupancy sensors OSA control when space is unoccupied and method(closes OSA damper or shuts-off <br /> equipment);or alternate means provided to automatically reduce OSA when space is partially <br /> nrcunie <br /> C403.2.6.4 Enclosed loading dock For enclosed loading docks,indicate ventilation/exhaust system method of activation(gas <br /> NA C403.2.6.4.1 ventilation detection system for CO and NO2,or occupancy sensors),and control method(staged or <br /> modulatinal <br /> NA C403.2.6.4 Enclosed parking garage For enclosed parking garages,indicate ventilation/exhaust system activated by gas detection <br /> C403.2.6.4.2 ventilation system for CO and NO2,and control method(staged or modulating);or exception taken <br /> Provide calculations that show a balanced accounting of total kitchen exhaust(include all <br /> hoods)with%of:supply air,transfer air from adjacent spaces,and make-up air;if applicable, <br /> NA C403.2.7.1 Kitchen exhaust hoods indicate that direct make-up air to each hood does not exceed 10%of hood exhaust <br /> For kitchens with total hood exhaust exceeding 2,000 cfm,indicate exhaust air rate per Table <br /> C403.2.7.1 and compliance method(DCV,energy recovery,or transfer air that would <br /> otherwise be exhausted) <br /> NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements <br /> Variable flow capacity- For HVAC fan motors a 7.5 hp,indicate method of variable flow control(VSD,or equivalent <br /> NA C403.2.13 HVAC system fans control method that reduces design air volume by 50%at 1/3 static design pressure);note <br /> excegfjor)taken <br /> DX air handler variable For DX air handlers with economizer and cooling capacity a 65,000 Btu/h,indicate number of <br /> cooling control cooling stages provided and method(multiple compressors and/or variable speed <br /> NA C403.3.1 (Under Integrated compressors):indicate minimum displacement(capacity reduction)as%of full load <br /> Economizer) Indicate control method(cooling capacity controlled in response to space temperature,space <br /> temperature controlled by modulating supply airflow,or both) <br /> For DX air handling units with cooling capacity a 65,000 Btu and evaporative and chilled <br /> water air handling units with fan a 0.25 hp,indicate whether system is single zone or multiple <br /> zone and related control method(cooling capacity controlled in response to space <br /> temperature,space temperature j�controlled by rpodulatina supply airflow,or both) <br /> For mechanical cooling systems(includes DX and cFlilled water coils that control cooling <br /> capacity in response to space temperature-Provide a minimum of two stages of fan control; <br /> NA C403.2.11.5 Fan airflow control indicate minimum fan speed is s 66%of full speed drawing 5 40%of full speed fan power <br /> during periods.of low coofna or v ntilation P <br /> For other mechanical cooing sysems tinclu es DX and chilled water coils)that control space <br /> temperature by modulating airflow(in lieu of,or in addition to,controlling capacity in response <br /> to space temperature)-Provide fan controls for modulating supply airflow;indicate minimum <br /> fan speed is 5 50%of full speed drawing 5 30%of full speed fan power during periods of low <br /> nnnlinn nr ventilatinn nnly nr axrantinn takan <br /> Provide central and zone level DDC controls as required based on system application,capacity <br /> NA C403.2.4.12 DDC system capabilities or size thsh ar qfici pe C3 <br /> Identify all re DDColds systemnd inputothe /outputualiat controloner Table points;indicate40 .2.4.12.1 capability for trending and <br /> nranhical display <br /> Ducting Systems <br /> C403.2.8.1 Indicate on plans that all ductwork is constructed and sealed per IMC M-0.2 <br /> Yes C403.2.8.3 Duct construction For OSA ductwork,also indicate on plans that ductwork meets air leakage requirements per <br /> C402.5 and vapor retarder requirements per the IBC <br /> Yes C403.2.8.3 Duct pressure classifications Identify location of low,medium and high pressure ductwork on plans M-0.2 <br /> NA C403.2.8.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide test results to <br /> test jurisdiction when completed <br />
The URL can be used to link to this page
Your browser does not support the video tag.