My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 COLBY AVE COLBY DINER 2022-01-27
>
Address Records
>
COLBY AVE
>
2720
>
COLBY DINER
>
2720 COLBY AVE COLBY DINER 2022-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:46:57 AM
Creation date
12/9/2021 12:07:46 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2720
Tenant Name
COLBY DINER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0. <br />r+ <br />1Buildin Anal sis Job: <br />OHEATING � Date: Jun 18, 2019 <br />COOLING Entire House By: <br />ELECTRICAL GS Heating & Cooling LLC <br />3409 Everett Ave, Everett, Wa 98201 Phone: 425-610-4257 Email: Jonathan@gsheating.com <br />•ect- Informa• <br />For: COLBY DINNER <br />2720 COLBY AVENUE, EVERETT, WA 98201 <br />Location: <br />Seattle -Tacoma Intl, WA, US <br />Elevation: 433 ft <br />Latitude: 47 ON <br />Outdoor: Heating <br />Dry bulb (OF) 20 <br />Daily range (OF) - <br />Wet bulb (IF) - <br />Wind speed (mph) 15 n <br />Indoor: <br />Indoor temperature (IF) <br />Design TD (OF) <br />Relative humidity (%) <br />Cooling <br />Moisture difference (gr/lb) <br />93 <br />Infiltration: <br />19 ( M) <br />Method <br />71 <br />Construction quality <br />7.5 <br />Component <br />Btuh/ft2 <br />Btuh <br />% of load <br />Walls <br />10.9 <br />711 <br />3.8 <br />Glazing <br />63.5 <br />4064 <br />21.7 <br />Doors <br />16.5 <br />347 <br />1.9 <br />Ceilings <br />13.8 <br />5245 <br />28.0 <br />Floors <br />0.8 <br />300 <br />1.6 <br />Infiltration <br />18.2 <br />1543 <br />8.2 <br />Ducts <br />0 <br />0 <br />Piping <br />0 <br />0 <br />Humidification <br />1284 <br />6.9 <br />Ventilation <br />5247 <br />28.0 <br />Adjustments <br />0 <br />Total <br />18741 <br />100.0 <br />Aua 1500 LDT <br />Component <br />Btuh/ft2 <br />Btuh <br />% of load <br />Walls <br />6.9 <br />451 <br />2.3 <br />Glazing <br />61.2 <br />3917 <br />20.4 <br />Doors <br />6.5 <br />137 <br />0.7 <br />Ceilings <br />22.3 <br />8485 <br />44.2 <br />Floors <br />0 <br />0 <br />0 <br />Infiltration <br />0 <br />0 <br />0 <br />Ducts <br />0 <br />0 <br />Ventilation <br />2365 <br />12.3 <br />Internal gains <br />3851 <br />20.1 <br />Blower <br />0 <br />0 <br />Adjustments <br />0 <br />Total <br />19206 <br />100.0 <br />Latent Cooling Load = 2460 Btuh <br />Overall U-value = 0.234 Btuh/ft2-IF <br />Data entries checked. <br />GI <br />Oth <br />Ceilings <br />Ceilings <br />Bold/italic values have been manually overridden <br />-Pk wrightsoft- <br />�• • ^ •Right-SuiteO Universal 2019 19.0.04 RSU22406 <br />... Colby Dinner 6-13-19\Drawings\Colby Dinner.rup Cale = CLTD Front Door faces: N <br />Right -Suite® Universal 2919 Short Form Date: e: Jun 18,2019 <br />rqs COOLING Entire House By: <br />ELECTRICAL GS Heating & Cooling LLC <br />3409 Everett Ave, Everett, Wa 98201 Phone: 425-610-4257 Email: Jonathan@gsheating.com <br />For: COLBY DINNER <br />2720 COLBY AVENUE, EVERETT, WA 98201 <br />Heating <br />Cooling <br />Htg Clg <br />Htg Clg <br />70 <br />70 <br />Outside db <br />(°F) 20 93 <br />Inside db <br />(°F) 70 70 <br />50 <br />23 <br />23 <br />50 <br />Outside RH <br />M) - 35 <br />Inside RH <br />(%) - 50 <br />21.0 <br />24.7 <br />Outside wb <br />(°F) - 71 <br />Inside wb <br />(OF) - 58 <br />Daily range <br />(°F) - 19 <br />Design TD <br />(°F) 50 23 <br />Simplified <br />Moisture diff. <br />(gr/lb) - 25 <br />Average <br />Heating Equipment <br />Cooling Equipment <br />atlon <br />Ventilation <br />Itration <br />nternal Gains <br />2019-Jul-09 09:13:32 <br />Page 1 <br />Make <br />Model <br />Type <br />Efficiency <br />Heating Input <br />Heating Output <br />Humidifier <br />Leaving Air Temp <br />Actual Heating Fan <br />Gas furnace <br />80 AFUE <br />0 <br />MBtuh <br />0 <br />MBtuh <br />3.5 <br />gpd <br />70.0 <br />IF <br />1037 <br />cfm <br />Equipment Location <br />System Type <br />Fan Motor Heat Type <br />Fan & Motor Combined Efficiency <br />Static Pressure Across Fan <br />Make <br />Model <br />Type <br />COP/EER/SEER <br />Sensible Cooling <br />Latent Cooling <br />Total Cooling <br />Leaving Air Temp <br />Actual Cooling Fan <br />Entire House <br />PEAKCV <br />PACKAGE <br />0 % <br />0 in H2O <br />Split AC <br />0 <br />0 MBtuh <br />0 MBtuh <br />0 MBtuh <br />55.0 OF <br />1037 cfm <br />NAME <br />Area <br />ft2 <br />Heat <br />Loss <br />Sensible <br />Gain <br />Latent <br />Gain <br />Htg <br />cfm <br />Clg <br />cfm <br />Time <br />Rooms <br />380 <br />18741 <br />19206 <br />2460 <br />1037 <br />1037 <br />Aug 1500 LDT <br />Entire House <br />380 <br />18741 <br />19206 <br />2460 <br />1037 <br />1037 <br />Aug 1500 LDT <br />wrightsoft" <br />• ,m•-n�mwm Right-Suiteg Universal 2019 19.0.04 RSU22406 <br />Colby Dinner 6-13-19\Drawings\Colby Dinner.rup Calc = CLTD Front Door faces: N <br />2019-Jul-09 09:13:32 / <br />6p) <br />Page <br />
The URL can be used to link to this page
Your browser does not support the video tag.