My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 COLBY AVE COLBY DINER 2022-01-27
>
Address Records
>
COLBY AVE
>
2720
>
COLBY DINER
>
2720 COLBY AVE COLBY DINER 2022-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:46:57 AM
Creation date
12/9/2021 12:07:46 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2720
Tenant Name
COLBY DINER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. <br />Job Name: <br />System Reference: <br />Date: <br />Indoor Unit: <br />MSZ-GL24NA <br />Outdoor Unit: <br />MUZ-GL24NA-U1 <br />MUZ-GL24NA-U2 <br />Wireless Remote Controller <br />Affl <br />GENERALFEATURES <br />• Slim wall -mounted indoor units provide zone comfort control <br />• The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns <br />• INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance <br />• Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto <br />• Multiple control options available: <br />Hand-held Remote Controller (provided with unit) <br />kumo cloud® smart device app for remote access <br />Third -party interface options <br />Wired or wireless controllers <br />• Quiet operation <br />• Smart Set: recalls a preferred preset temperature setting at the touch of a button <br />• Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life <br />Specifications are subject to change without notice. <br />© 2019 Mitsubishi Electric Trane HVAC US LLC. All riahts reserved. <br />Maximum Capacity <br />Btu/h <br />31,400 <br />Rated Capacity <br />Btu/h <br />22,500 <br />Minimum Capacity <br />Btu/h <br />8,200 <br />Cooling <br />Maximum Power Input <br />W <br />3,522 <br />Rated Power Input <br />W <br />-- <br />1,800 <br />Moisture Removal <br />Pints/h <br />5.1 <br />Sensible Heat Factor <br />0.75 <br />Power Factor <br />% <br />99 / 99 <br />Maximum Capacity <br />Btu/h <br />36,900 <br />Rated Capacity <br />Btu/h <br />27,600 <br />Heating 47°F2 <br />Minimum Capacity <br />Btu/h <br />7,500 <br />at <br />Maximum Power Input <br />W <br />3,592 <br />Rated Power Input <br />W <br />2,340 <br />Power Factor <br />Maximum Capacity <br />% <br />99 / 99 <br />Btu/h <br />24,600 <br />Heating 17°F3 <br />Rated Capacity <br />Btu/h <br />16,000 <br />at <br />Maximum Power Input <br />W <br />3,232 <br />Rated Power Input <br />W <br />1,712 <br />Heating 5°F4 <br />Maximum Capacity <br />Btu/h <br />19,320 <br />at <br />Maximum Power Input <br />W <br />2,990 <br />Heating at -4°F5 <br />Maximum Capacity <br />Btu/h <br />15,450 <br />SEER <br />20.5 <br />EER' <br />12.5 <br />HSPF (IV) <br />10.0 <br />Efficiency <br />COP at 47°F2 <br />3.46 <br />COP at 17°F in Maximum Capacity3 <br />2.23 <br />COP at 5°F in Maximum Capacity° <br />1.89 <br />ENERGY STARO Certified (ENERGY STAR products are third -party certified by <br />an EPA -recognized Certification Body.) <br />YES <br />Voltage, Phase, Frequency <br />208/230V, 1 phase, 60Hz <br />Guaranteed Voltage Range <br />VAC <br />187 - 253 <br />Voltage: Indoor - Outdoor, S1-S2 <br />VAC <br />208 / 230 <br />Electrical <br />Voltage: Indoor - Outdoor, S2-S3 <br />V DC <br />24 <br />Voltage: Indoor - Remote Controller <br />Wireless Type <br />Recommended Fuse/Breaker Size <br />A <br />20 <br />Recommended Wire Size (Indoor - Outdoor) <br />AWG <br />14 <br />MCA <br />A <br />1 <br />MOCP <br />A <br />20 <br />Indoor Unit <br />Blower Motor Full Load Amperage <br />A <br />0.76 <br />Blower Motor Output <br />W <br />56 <br />Airflow Rate at Cooling, Dry <br />CFM <br />738-628-544-469-388 <br />Specifications are subject to change without notice. <br />© 2019 Mitsubishi Electric Trane HVAC US LLC <br />All rights reserved. � <br />
The URL can be used to link to this page
Your browser does not support the video tag.