My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 COLBY AVE COLBY DINER 2022-01-27
>
Address Records
>
COLBY AVE
>
2720
>
COLBY DINER
>
2720 COLBY AVE COLBY DINER 2022-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:46:57 AM
Creation date
12/9/2021 12:07:46 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2720
Tenant Name
COLBY DINER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. <br />2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 <br />• • - • • • • <br />2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all Ri Revised January 2017 <br />Project Title: COLBY DINNER <br />Date 7/9/2019 <br />• <br />y <br />* <br />All cooling systems <br />system capacity, for <br />this requirement are <br />to and additional information <br />shall be configured to provide air economizer operation, regardless of <br />new construction and mechanical system alterations. Various exceptions to <br />available. Identify all systems that an economizer exception will be applied <br />as noted below. <br />For Building Dept. Use <br />Economizer <br />Exception <br />Summary <br />Refer to Section <br />C403.3 for <br />descriptions of <br />economizer <br />provisions and <br />exceptions. For <br />alterations refer <br />to SectionC503 <br />Table C503.4. and <br />Table <br />ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS <br />Exp 1 Cooling equipment serving spaces that are provided with a dedicated <br />outdoor air system (DOAS) per C403.6. Spaces served shall have year- <br />round design cooling loads from lights and equipment less than 5 watts per <br />square foot. <br />System ID <br />Lighting + <br />Equipment <br />Loads (W/sf) <br />Exp 2 Single zone unitary or package systems with dehumidification that affect <br />other systems such that air economizer would increase energy <br />consumption. <br />System ID <br />Exp 3 High efficiency single zone unitary or packaged systems. Equipment <br />cooling efficiency shall be better than the WSEC required minimum <br />efficiency by at least 64% in Climate Zone 4C and 59% in Climate Zone 5B <br />per Table C403.3. <br />System ID <br />Exp 4 Equipment that provides hydronic chilled water for chilled beams and <br />chilled ceiling systems that is served by a water economizer system per <br />C403.3.4 in lieu of air economizer. <br />System ID <br />Exp 5 Water -source heat pumps with heat recovery. Heat pump efficiency shall <br />be 15% better than WSEC required minimum efficiency. Provide at <br />minimum 60% air economizer. Energy recovery to preheat OSA shall <br />have at least 50% effectiveness. Additional system requirements apply. <br />System ID <br />Exp 6 Cooling equipment serving Group R occupancies. Per unit limit <br />is less than 20,000 Btu/h cooling capacity for equipment installed <br />outdoors or in a meth room adjacent to the outdoors. For cooling <br />equipment installed in other locations the unit limit is less than <br />54,000 Btu/h. Efficiency shall be 15% better than WSEC <br />required minimum efficiency. <br />i <br />System ID <br />Equipment <br />Location <br />Cooling <br />Capacity <br />(Btu/h) <br />Exp 7 Variable refrigerant flow (VRF) systems with energy recovery. Outdoor <br />unit shall be a reverse -cycle heat pump with variable speed <br />compressor(s) and condenser fan(s). Outdoor unit cooling capacity shall <br />be not less than 65,000 Btu/h. Energy recovery to preheat outdoor air <br />shall have at least 50% rated effectiveness. System shall be capable of <br />providing simultaneous heating and cooling by tranferring recovered <br />energy from zone(s) in cooling mode to other zone(s) that are in heating <br />mode. <br />Outdoor Unit <br />System ID <br />Cooling <br />Capacity <br />(Btu/h) <br />Exp 8 Cooling equipment serving Controlled Plant Growth Environments. <br />Equipment cooling efficiency shall be better than WSEC required <br />minimum efficiency by at least 20%. Not eligible: unitary and applied <br />heat pumps. <br />System ID <br />SEER, EER, & <br />IEER <br />Exp 9 Cooling equipment with energy recovery. Spaces served shall have <br />year-round design cooling loads from lights and equipment greater than <br />5 watts per square foot. Energy recovery system shall utilize recovered <br />energy for on -site space heating or preheating of service hot water. <br />Provide calculations to the code official that demonstrate the amount of <br />recovered energy used for on -site heating purposes is equivalent to the <br />annual energy that would be saved by the cooling system with air <br />economizer per C403.3. <br />System ID <br />Lighting + <br />Equipment <br />Loads (W/sf) <br />2015 Washinaton State Enerav Code Compliance Forms for Commercial. R2 and R3 over 3 stories and all R1 <br />'Edoh• -• •cont.• • <br />2015 Washin on State nergyCode Com liance Forms for Commercial Buildin s incu ing R2 & R3 over 3 stories and all R1 Revised Januar 2017 <br />Project Title: Date 7 / 9/2 019 <br />ECONOMIZER EXCEPTIONS - NEW CONSTRUCTION AND ADDITIONS, CONTINUED <br />Economizer <br />Exception <br />Summary <br />Refer to Section <br />C403.3 for <br />descriptions of <br />Exp 10 Cooling equipment for dedicated server, electronic equipment or Compliance <br />telecom switch rooms. Per building limit for this exception is System ID Option <br />240,000 Btu/h cooling capacity or 10% of required building air <br />economizer capacity, whichever is greater. Part load control <br />required over 85,000 Btu/h. Additional requirements apply. <br />Option a - Cooling equipment efficiency shall be 15°% better than <br />the WSEC required minimum efficiency.. <br />Option b - Waterside economizer required. Cooling equipment <br />efficiency shall be 5% better than the WSEC required <br />minimum efficiency. <br />Option c - Waterside economizer required. All cooling equipment is <br />subject to ASHARE Standard 127. Total Claimed Exempt Capacity: <br />Total building air economizer capacity (if claimed > 240 kBtu/h): <br />Alternate Exp 10 Capacity Limit: <br />Cooling <br />Capacity <br />(Btu/h) <br />economizer <br />provisions and <br />exceptions. For <br />alterations refer <br />to Section <br />C503.4 and <br />Table C503.4. <br />ECONOMIZER EXCEPTIONS - MECHANICAL SYSTEM ALTERATIONS OR REPLACEMENT <br />C503.4 Pre -approved design alternative to full compliance with air economizer <br />Exp 1 requirement. An alternative for mechanical system alterations where existing <br />building constraints make full compliance with air economizer requirement <br />impractical. Provide calculations to the code official that demonstrate the <br />proposed alternate design strategy provides similar energy savings to the <br />annual energy that would be saved by the cooling system with air economizer <br />per C403.3. <br />System ID <br />Alt. Strategy <br />ECONOMIZER EXCEPTIONS - SIMPLE SYSTEMS <br />C503.4 Qualifying small equipment. Per unit limit less than 33,000 Btu/h. Per System ID <br />Exp 2 building limit for this exception is 72,000 Btu/h cooling capacity or 5% of <br />required building air economizer capacity, whichever is greater. Cooling HP-1 <br />equipment efficiency shall be 15% better than WSEC required minimum <br />efficiency. Not eligible: non -unitary equipment, unitary equipment installed <br />outdoors or in meth room adjacent to outdoors, equipment installed during <br />new construction, shell -and -core construction, or initial tenant <br />improvement. <br />Total Claimed Exempt Capacity: <br />Total building air economizer capacity (if claimed > 72,000 Btu/h): <br />Alternate C503.4 Exp 2 Capacity Limit: <br />Cooling <br />Capacity <br />(Btu/h) <br />24,000 <br />24,000 <br />C503.4 Equipment that provides hydronic chilled water for chilled water terminal <br />Exp 3 units. Equipment part load cooling efficiency (IPLV) shall be better than System ID <br />WSEC required minimum efficiency by at least 25%. Per building limit <br />for this exception is 480,000 Btu/h cooling capacity or 20°% of required <br />building air economizer capacity, whichever is greater. Chilled water <br />terminal units serving Group R occupancies are not included in the <br />building capacity total. <br />Total Claimed Exempt Capacity: <br />Total building air economizer capacity (if claimed > 480,000 Btu/h): <br />Alternate C503.4 Exp 3 Capacity Limit: <br />Cooling <br />Capacity <br />(Btu/h) <br />Table Compliance Options for alteration or replacement of existing <br />C503.4 mechanical cooling equipment per Table C503.4. Refer to table <br />and all applicable table footnotes for full requirements. Applies to <br />the following retrofit conditions: <br />Option a - Any new or replacement equipment <br />Option b - Replacement equipment of same type with same or <br />smaller cooling output'capacity. <br />Option c - Replacement equipment of same type with large <br />cooling output capacity. <br />Option d - New equipment added to existing system or <br />replacement equipment that is different than existing <br />being replaced. <br />System ID <br />Equipment <br />Type <br />Compliance <br />Path <br />
The URL can be used to link to this page
Your browser does not support the video tag.