Laserfiche WebLink
SNOmISLE TECH SKILLS CENTER <br />WELDING SHOP REMODEL <br />MUKILTEO SCHOOL DISTRICT NO.6 <br />Everett, Washington <br />PERMIT SET <br />02 APRIL , 2021 <br />PROJECT DATA PROJECT TEAM SHEET INDEX SYM80LS ABBREVIATIONS GENERAL PROJECT NOTES <br />PROJECT DESCRIPTION <br />OWNER <br />PROJECT SCOPE INCLUDES INTERIOR REMODEL <br />MUKILTEO SCHOOL DISTRICT <br />OF EXISTING WELDING SHOP: DEMOLITION OF <br />9401 SHARON DRIVE <br />EXISTING WELDING BOOTH PARTITIONS, <br />EVERETT, WA 98204 <br />INSTALLATION OF NEWWELDING BOOTHS <br />PHONE: 425.356.6625 <br />CONSTRUCTION OF AN OFFICE WITHIN EXISTING <br />WELDING SHOP SPACE. WORK ALSO INCLUDES <br />MECHANICAL/ELECTRIAL MODIFICATIONS AS <br />REQUIRED TO SUPPORT REMODELED SPACES. <br />ARCHITECT <br />MCGRANAHAN ARCHITECTS <br />PROJECT ADDRESS <br />2111 PACIFIC AVENUE, SUITE 100 <br />900E Airport Road <br />P <br />TACOMA, WA 98402 <br />Everett, WA 98204 <br />PHONE: 253.383.3084 <br />SNOHOMISH COUNTY TAX PARCEL NUMBER <br />28041400203100 <br />MECHANICAL ENGINEER <br />BCE ENGINEERS, INC. <br />LEGAL DESCRIPTION <br />602E 12TH STREET E, SUITE 200 <br />SEC 14 TWP 28 RGE 04TH PTN NWIA DAF - COM <br />FIFE, WA 8424 <br />SIA COR SEC 14 TH N00*54 45W ALG CTR SEC LN <br />53.92 <br />PHONE: 253.922.0446 <br />2639.485FT TO CTR SD SEC TH N00*55 36W ALG SD <br />CTR SEC LN 1316.366FT TO NE COR S1/2 NW1/4 TH <br />N89*48 49W ALG N LN S1I2NW1 /4 2636.351 FT TO W <br />LN SD SEC TH S00*53 34E ALG W SEC LN 100.018FT <br />TPB TH CONT S00*53 34E 914.358FT TH S89*48 49E <br />ELECTRICAL ENGINEER <br />1191.211 FT TH N00*53 34W 914.358FTTH N89*48 <br />BCE ENGINEERS, INC. <br />49W 1191.211 FT TPB <br />6021 12TH STREET E, SUITE 200 <br />FIFE, WA 98424 <br />PHONE: 253.922.0446 <br />JURISDICTION REFERENCE <br />City of Everett <br />ZONING DESIGNATION <br />COST ESTIMATOR <br />City of Everett: Light Industrial 2 (1-I2) <br />RC COST GROUP <br />917 PACIFIC AVENUE, SUITE 505 <br />TACOMA, WA 98402 <br />LOT AREA <br />PHONE: 253.258.2925 <br />24.83 ACRES <br />BUILDING AREA <br />EXISTING BUILDING 2: <br />36,895 SF (including horizontal projections) <br />*NO CHANGE IN AREA WITH THIS PROJECT* <br />PROJECT <br />NORTH % i . 'A l ike ■ "' % i <br />■ A A r.% <br />GENERAL OFFICE ROOM NAME MATL MATERIAL 1. REFERENCE FIRST SHEET IN EACH DRAWING SERIES FOR ADDITIONAL APPLICABLE GENERAL NOTES. <br />G0.00 COVER SHEET AND PROJECT INFORMATION D101 AND NUMBER A AT <br />AB ANCHOR BOLT MAX MAXIMUM <br />G0.01 CODE ANALYSIS & EGRESS PLAN ACOUST ACOUSTICAL MB MACHINE BOLT INCL WASHER / NUT 2. ALL WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES UNLESS OTHERWISE <br />09A2B WALL TYPE INDICATOR, ACT ACOUSTICAL CEILING TILE MECH MECHANICAL NOTED ON THE DRAWINGS AND SPECIFICATIONS. THE GENERAL CONTRACTOR SHALL COORDINATE <br />ARCHITECTURAL <br />DEMOLITION <br />SEE WALL TYPES SHEET ADJ ADJACENT M/E/P OR MEP MECHANICAL, ELECTRICAL, AND PLUMBING THE GENERAL NOTES WITH THE WORK OF ALL TRADES, INCLUDING BUT NOT LIMITED TO THE <br />AED AUTOMATIC EMERGENCY. DEFIBRILLATOR &CABINET MFR MANUFACTURER MECHANICAL, ELECTRICAL, AND ACOUSTICAL TRADES. <br />AD2.01 DEMOLITION FLOOR PLAN MH MANHOLE <br />BUILDING AFF ABOVE FINISH FLOOR <br />AD2.11 EXISTING PHOTOGRAPHS a4l, �01 01 ALUM ALUMINUM MICRO MICROWAVE 3. THE CONTRACTOR SHALL VISIT THE SITE AND BE KNOWLEDGEABLE OF CONDITIONS THEREOF. <br />SECTION ANOD ANODIZED A0.01 MIN MINIMUM THE CONTRACTOR SHALL INVESTIGATE VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE <br />A0.01 <br />ARCHITECTURAL ASPH ASPHALT MLDG MOLDING PROJECT AND SHALL NOTIFY THE OWNERIARCHITECT OF CONDITIONS REQUIRING MODIFICATION <br />A2.01 FLOOR PLAN ASSY ASSEMBLY MTL METAL BEFORE PROCEEDING WITH THE WORK. <br />A3.01 REFLECTED CEILING PLAN & INTERIOR ELEVATIONS ATTACH ATTACHMENT NATL NATURAL <br />01 ALT ALTERNATE NIC NOT IN CONTRACT 4. WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS BY VARIOUS DISCIPLINES, ARCHITECTURAL DRAWINGS <br />A10.01 DOOR SCHEDULE, FRAME TYPE & DETAILS, SIGNAGE SCHEDULE & TYPE WALL SECTION <br />SHALL GENERALLY BE ASSUMED TO GOVERN. IN SUCH INSTANCES THE CONTRACTOR SHALL CONSULT THE <br />A0.01 BD OR BIRD BOARD NO NUMBER <br />BF BARRIER FREE NR NOT RATED ARCHITECT BEFORE PROCEEDING WITH THE WORK. <br />MECHANICAL BITUM BITUMINOUS NOM NOMINAL <br />M1.01 MECHANICAL LEGEND, SCHEDULES & ABBREVIATIONS BLDG BUILDING NTS NOT TO SCALE 5. CONDITIONS WHICH ARE NOT DETAILED SHALL BE ASSUMED TO BE SIMILAR IN CHARACTER TO THOSE WHICH <br />MD2.01 PARTIAL FIRST FLOOR DEMOLITION PLANS 01 DETAIL CUT BLKG BLOCKING OC ON CENTER ARE. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CAN NOT BE DETERMINED THE CONTRACTOR <br />A0.01 BM BEAM OD OUTSIDE DIAMETER SHALL NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. <br />M2.01 PARTIAL FIRST FLOOR MECHANICAL PLANS BO BOTTOM OF OF OVERFLOW <br />M3.01 MECHANICAL NOTES BOTT BOTTOM OVHD OVERHEAD 6. CONSTRUCTION OF WORK INDICATED ON DRAWINGS AS (NIC) IS NOT IN CONTRACT. THE CONTRACTOR <br />1 BTWN BETWEEN OPER OPERABLE SHALL COORDINATE ALL TRADES OF HIS WORK, WHETHER DIRECTLY OR INDIRECTLY INVOLVED, WITH <br />ELECTRICAL 1 BRG BEARING OPP OPPOSITE HAND NIC WORK, <br />E0.01 ELECTRICAL LEGEND 0E ^ INTERIOR / EXTERIOR CB CATCH BASIN OPNG OPENING <br />2 4 OR 11A0.0E ELEVATION ELEVATION CEM CEMENT OTS OPEN TO STRUCTURE 7. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE CODES AND GOVERNING AUTHORITIES <br />ED2.01 LIGHTING DEMOLITION PLAN A0.01 <br />CG CORNER GUARD OTA OPEN TO ABOVE AND SHALL BE OF BEST PRACTICE OF EACH TRADE <br />E2.01 LIGHTING PLAN CJ CONTROL JOINT OVHG OVERHANG <br />E3.01 POWER PLAN 3 CLG CEILING PENE PENETRATION 8. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. DO NOT SCALE THE DRAWINGS. <br />E6.11 PANEL SCHEDULES CMU CONCRETE MASONRY UNIT PERF PERFORATED <br />CO CLEAN OUT PI POST INDICATOR 9. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO PROCEEDING WITH THE WORK. THE <br />E DETAIL COL COLUMN PJSC PROJECTION SCREEN CONTRACTOR IS TO NOTIFY THE ARCHITECT OF ANY DISCREPANCIES/ CORRECTIONS. <br />A0.01 CONC CONCRETE PL PLATE <br />CORK CORRIDOR PLAM PLASTIC LAMINATE 10. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES AND SUPPORTING <br />CORRUG CORRUGATED PLAS PLASTER BRACKETS REQUIRED FOR THE BEST POSSIBLE INSTALLATION OF ALL OWNER FURNISHED ITEMS, AND ALL WALL <br />CL CENTER LINE PNL PANEL MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL OR MISCELLANEOUS EQUIPMENT. <br />CPT E-V T FLR MATERIAL BREAK CLR CLEAR PNT PAINT <br />CONN CONNECT POLY POLYSTYRENE 11. THE FLAME SPREAD RATING FOR ALL MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES. <br />CONT CONTINUOUS PR PAIR <br />CPT CARPET PROT PROTECTION 12. REFER TO CERTIFIED MECHANICAL AND ELECTRICAL CONTRACTOR'S DRAWINGS AND MANUFACTURER'S <br />CSA CLADDING SUPPORT ASSEMBLY PSI POUND PER SQUARE INCH TEMPLATE DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL EQUIPMENT SUPPORTS, BOLT SETTING <br />CSK COUNTERSINK PT PRESSURE OR PRESERVATIVE TREATED TEMPLATES, SPRING AND VIBRATION ISOLATORS, ETC. NOT SHOWN ON DRAWINGS. <br />CW CURTAINWALL PTN PARTITION <br />DOOR NUMBER D CLOTHES DRYER PVC POLYVINYL CHLORIDE 13. PROVIDE PROPER ANCHORAGE OF ESSENTIAL EQUIPMENT IN ACCORDANCE WITH APPLICABLE CODES. <br />DBL DOUBLE PW OR PLYWD PLYWOOD <br />OSF01 WINDOW TYPE DEMO DEMOLISH QT QUARRY TILE 14. ALL PIPE DUCTS, BUSS DUCTS AND CONDUITS THAT PENETRATE FLOOR SLABS AND/OR RATED WALLS SHALL BE <br />DF DRINKING FOUNTAIN R RISER INSTALLED IN A MANNER WHICH WILL PRESERVE THE FIRE RESISTIVE AND STRUCTURAL INTEGRITY OF THE <br />DIA, 0 DIAMETER RAD RADIUS BUILDING. <br />DN DOWN RCP REFLECTED CEILING PLAN <br />DO DITTO OR REPEAT ADJACENT ELEMENT RD ROOF DRAIN 15. COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL, ELECTRICAL AND CEILING INSTALLER. <br />DR DOOR RE REFER TO WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND INSTALLATION, THE GENERAL CONTRACTOR SHALL <br />DS DOWNSPOUT REF REFRIGERATOR CONSULT WITH THE ARCHITECT PRIOR TO THE PROCEEDING WITH THE WORK. <br />R01 DWG(S) DRAWING(S) RES RESILIENT <br />INTERIOR RECITE TYPE (E) OR EXIST EXISTING REQD REQUIRED 16, PROVIDE ACCESS PANELS FOR MECHANICAL AND ELECTRICAL EQUIPMENT AS REQUIRED BY APPLICABLE CODES. <br />EA EACH RM ROOM ALL ACCESS PANELS SHALL BE CONCEALED AND LCOATIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR <br />EIFS EXTERIOR INSULATION FINISH SYSTEM RR RESTROOM REVIEW PRIOR TO START OFTHE WORK. ELECTRICAL"J" BOXES, PLUMBING CLEAN OUTS, FIRE DAMPERS AND <br />A - GRID LINE EJ EXPANSION JOINT RUB RUBBER OTHER SIMILAR ITEMS REQUIRING ACCESS ARE NOT TO BE LOCATED ABOVE GYPSUM BOARD OR SIMILAR <br />ELECT ELECTRICAL RWL RAIN WATER LEADER CEILINGS. <br />ELEV OR EL ELEVATION SAC SUSPENDED ACOUSTICAL CEILING <br />EMER EMERGENCY SAM SELF ADHERED MEMBRANE 17. THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT PRIOR TO STARTING THE WORK COMPREHENSIVE LAYOUT <br />- - CENTER LINE EMBED EMBEDMENT SCHED SCHEDULE DRAWINGS INDICATING DIMENSIONAL LOCATION OF ALL VISIBLE BUILDING ELECTRICAL, AUTOMATION, SECURITY, <br />EN ENAMEL SC SOLID CORE LIFE SAFETY, CONTROL, ETC. EQUIPMENT. <br />ENL ENLARGED SCL STRUCTURAL COMPOSITE LUMBER <br />EPS EXPANDED POLYSTYRENE SD SOAP DISPENSER 18. THE CONTRACTOR SHALL COORDINATE AND PROVIDE ALL SLAB AND WALL OPENINGS REQUIRED BY MECHANICAL <br />EQ EQUAL SEC SECURITY AND ELECTRICAL DRAWINGS. <br />EQUIP EQUIPMENT SF STOREFRONT <br />15'-8" EXP EXPANSION SHEATH SHEATHING 19. THE INSULATION CONTRACTOR IS TO PROVIDE A CERTIFICATE OF COMPLIANCE TO THE ARCHITECT/OWNER UPON <br />REFERENCE EXT EXTERIOR SHT SHEET THE COMPLETION OF WORK. <br />T 0 SLAB OR ELEVATION EXTR EXTRUDED SIM SIMILAR <br />- (� <br />100-6 _ FB ELECTRICAL FLOOR BOX SPEC SPECIFICATION. 20. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO PREVENT MOLECULAR <br />FD FLOOR DRAIN Sp STANDPIPE ASSY INCL FIRE EXTINGUISHER BREAKDOWN AND GALVANIC ACTION. <br />OR WORK POINT FE FIRE EXTINGUISHER - SEE SYMBOLS <br />FE-K FIRE EXTINGUISHER- KITCHEN TYPE - SEE SYMBOLS SSPEAKER <br />FEC. FIRE EXTINGUISHER CABINET -SEE SYMBOLS SQ SQUARE 21. CEILING HEIGHT DIMENSIONS ARE FROM DESIGNED FINISHED FLOOR TO FINISHED CEILING SURFACES UNLESS <br />F FACTORY FINISH S/S OR SS STAINLESS STEEL NOTED OTHERWISE. <br />FFIRE HYDRANT STC SOUND TRANSMISSION COEFFICIENT <br />F <br />STD STANDARD 22. PROVIDE FIRE DAMPERS OR DOORS WHERE DUCTS PENETRATE FIRE RATED WALLS OR CEILINGS UNLESS NOTED <br />FIN FINISHED) STL STEEL OTHERWISE. <br />FLASHG FLASHING STOR STORAGE <br />FEC SEMI -RECESSED FIRE EXTINGUISHER CABINET FLR FLOOR OR FLOORING STRUCT STRUCTURAL 23. GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED SIGNAGE (MAXIMUM OCCUPANT LOAD, BUILDING <br />-�` FM FACTORY MUTUAL SUSP SUSPENDED ACCESSIBILITY, ETC.) AS REQUIRED BY LOCAL BUILDING CODE AUTHORITY IN ORDER TO RECEIVE PERMANENT <br />FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR T TREAD PROJECT OCCUPANCY. <br />SURFACE MOUNTED FIRE FOIO FURNISHED BY OWNER INSTALLED BY OWNER T & G TONGUE & GROOVE <br />�O FE EXTINGUISHER F0 FACE OF TERM TERMINATION 24. ALL SURFACES EXPOSED TO VIEW SHALL BE PROVIDED IN A FINISHED CONDITION (PAINTED, SEALED, CLEANED, <br />FP FIREPLACE THRESH THRESHOLD ETC). <br />FIRM FRAME TO TOP OF <br />9 CG CORNER GUARD FRMG FRAMING TRTD TREATED 25. DEMOLITION/CONSTRUCTION SHALL CONFORM TO CHAPTERS 14 IFC AND 33 IBC. <br />FRP FIBERGLAS REINFORCED PANEL(S) TYP TYPICAL <br />FRZ FREEZER TS TUBE STEEL <br />EXPANSION JOINT FT ` FOOT OR FEET UL UNDERWRITERS LABORATORY <br />E J GA GAUGE LINO UNLESS NOTED OTHERWISE <br />GALV GALVANIZED U/S UNDER SIDE <br />GL GLASS VCT VINYL COMPOSITION TILE FE3 <br />ERETT FIRE DEPT. REVIEW <br />GLU-LAM GLUE LAMINATED VIF VERIFY IN FIELD <br />C J CONTROL JOINT GWB GYPSUM WALL BOARD V PLAS VENEER PLASTER PPROVED <br />GYP GYPSUM VERT VERTICAL PPROVED WITH CHANGES NOiEO <br />ICEIWATER SHIELD, HDBD HARDBOARD VWC VINYL WALL COVERING C��'�� r r. �� E _ i ,�1.. REVISE AND RESUaMi{ <br />�(3 <br />HC HANDICAP rl REJECTED• <br />architect <br />MCGRANAHAN ARCHITECTS <br />mechanical engineer - <br />BCE ENGINEERS <br />electrical engineer <br />BCE ENGINEERS <br />9440 REGISTERED <br />ARCHITECT <br />ANDREW M H UNG <br />STATE OF WA HINGTON <br />project- <br />SNO-ISLE TECH SKILLS CENTER <br />WELDING SHOP REMODEL <br />client_ <br />MUKILTEO SCHOOL DISTRICT NO.6 <br />location- <br />EVERETT. WA <br />Project No. 2017.000 <br />COVER SHEET <br />AND PROJECT <br />INFORMATION <br />W WASHING MACHINE <br />Tro REV1E 1lVEt FOR PERT` H,IuNoauT <br />AIR BARRIER <br />M.. r HDWRE HARDWARE SE <br />£D CMECKils1'/ <br />W/ WITH 0 S ATTACHED <br />PROOFING, WB WHITE BOARD <br />DAMP PR00 <br />.,, WATER PROOFING HGT HEIGHT <br />a 2 SUEZ!..:, HM HOLLOW METAL <br />s WC WATER CLOSET The issuance of 8 permit shall not <br />11 <br />g, .; -:_ I late issued <br />»x ..,,.. w HORIZ HORIZONTAL 85 authortht t© YlO <br />>. z F WIDE FLANGE be construed - <br />,... 4 N/ <br />HOUR t DOCUMENTS HAVE N provision of <br />HRWDO WINDOW ®T SEEN cancel of set aside 8>fiX PERMIT 02 APR 21 <br />APPROVED <br />.- - - 91 A Eother <br />40 A FINISH CODE DESIGNATION, SEE SHEET A . 1 HSS HOLLOW STRUCTURAL SHAPE Wp WOOD FOR THE ISSUANCE ®F ire Cps or the Everett <br />ID INSIDE DIAMETER WHS WELDED HEAD STUD PU�LiC WORKS, �,CHANiGAL, FIRE Or {SMfS. The <br />e. u IE INVERT ELEVATION MAT SUPPRESSION, ELECTRICAL OR <br />app{Icabte regulations <br />issuance 0i 8'p6fH1{t revision <br />v i s i o n <br />= INCL INCLUDE OR INCLUDING OFF PLUMBING PERMITS. tl - <br />ay WPM WALL PAD r <br />INT INTERIOR COt1StrUC; dCCY <br />s ;- - MATERIAL SYMBOL KEY WR WATER RESISTANT <br />S5 <br />.. , INSULATION to shall Mlt Fie Coft <br />F WELDED FABRIC <br />ANITORCq►I+�K.rtlOn <br />r JAN L JRequired #fOm idling <br />aortt:t�.._. - <br />�[d=,r,� Win,:' ,,, Clai Permits <br />n; .; JT JOINT �ddl$10 <br />WW W � Are <br />. '. <br />r,r � Include, <br />�, t TO f <br />��. Project <br />:.. <br />i,r�>ss, JST JOIST r Ti11S P <br />�.rv.o <br />a, y ,s ��`, EXPOSED WOOD L ANGLE <br />... Sprinkler <br />' <br />. 3 LAM LAMINATE b1E1 <br />Plum <br />y <br />Mo�,ltn.. OR # POUND <br />r Fire Alarm <br />Mechanical <br />LLH LONG LEG HORIZONTAL MCC. <br />_ WOOD FRAMING <br />bx z wry : , „ '^✓a ,-q <br />LLV LONG LEG VERTICAL <br />,. <br />. LOC LOCATION Electrical <br />,. a�s� <br />tcr€ <br />� . • 3 PLYWOOD <br />y <br />., ... 01 <br />ay r` ✓. .. r <br />i. <br />% 29 <br />Permit#: B2104�0 <br />y <br />s . <br />r <br />, .,..> .m /8 E <br />;' ��, � , r •- � r . „s ,. 9Q01 AIRPORT RD BLDG 2 <br />� i GWB 5 TYPE X LINO <br />,. I <br />�� -- <br />Address: <br />F* KILTEO SCHOOL DIST 6 <br />ME <br />• Owner: <br />.. `;. Site Add <br />�,�,` MU <br />tt- ��: <br />- KILLS CENTER <br />�.. ,., . ,, aw..,a.;d3r� r , <br />��o �.,R.�,�:; �_,,., s,,,,, :+ Tenant:SNO ISLES <br />BATT INSULATION <br />App. Date: 4/8/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: REMODEL OF EXTG WELDING SHOP W/ AN <br />OFFICE WITHIN THAT SPACE <br />RIGID INSULATION <br />■ <br />Reviewed By: Date: //lam \` � <br />architects <br />DEC= <br />Office Set 1oh Site Set FirefPlanning Set <br />1/2" SEALANT JOINT � l"!LQ <br />McGRANAHAN WITH BACKER ROD nri <br />ORIGINAL SHEET IS 30" x 42" <br />copyright 2020 <br />all rights reserved <br />APR Q 7 2021 sheet_ <br />*NOTE: SEE INDIVIDUAL DRAWINGS FOR LEGENDS & <br />DEFINITION OF POCHE USED TO REPRESENT LARGE AREAS CITY OF EVERETT <br />OF REPETITIVE MATERIALS. a GO,00 <br />Permit Services <br />