CODE ANALYSIS <br />arch ltecl_ <br />MCGRANAHAN ARCHITECTS <br />APPLICABLE CODES: <br />MIXED USEAOCCUPANCY ([ CCHAPTER 5 CONT. <br />MEANS (IBC CTERj�� <br />rnecIaanIceI engineer - <br />CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE FOLLOWING: <br />505.3 EQUIPMENT PLATFORMS. SHALL NOT BE CONSIDERED AS A PORTION OF THE FLOOR BELOW NOR CONTRIBUTE TO EITHER THE BUILDING AREA OR NUMBER OF STORIES. <br />1004 <br />SEE EGRESS PLANS FOR IDENTIFIED EGRESS ROUTES AND OCCUPANT LOADS. <br />BCE ENGINEERS <br />THE AREA AREA SHALL NOT BE INCLUDED IN DETERMINING THE FIRE AREA. EQUIPMENT PLATFORMS SHALL NOT SERVE AS PART OF THE MEANS OF EGRESS FROM THE BUILDING. <br />1004.1.1 <br />CUMULATIVE OCCUPANT LOADS. WHERE THE PATH OF EGRESS TRAVEL INCLUDES INTERVENING ROOMS, AREAS OR SPACES, CUMULATIVE OCCUPANT LOADS SHALL BE DETERMINED IN <br />NATIONAL CODES: <br />NO CHANGES TO EXISTING EQUIPMENT PLATFORMS. <br />ACCORDANCE wl THIS SECTION. <br />2018 EDITION -INTERNATIONAL EXISTING BUILDING CODE (IEBC) <br />508.3 NONSEPARATED OCCUPANCIES. BUILDING OR PORTION OF BUILDINGS THAT COMPLY WITH THE PROVISIONS OF THE SECTION SHALL QUALIFY AS NONSEPARATED OCCUPANCIES. <br />1004.1.1.1 <br />INTERVENING SPACES OR ACCESSORY AREAS: WHERE OCCUPANTS EGRESS .FROM ONE OR MORE ROOMS, AREAS OR SPACES THRU OTHERS, THE DESIGN OCCUPANT LOAD SHALL BE <br />electrical engineer_ <br />2018 EDITION - INTERNATIONAL BUILDING CODE (IBC) <br />508.3.1 OCCUPANCY CLASSIFICATION. NONSEPARATED OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE REQUIREMENTS OF THIS CODE <br />THE COMBINED OCCUPANT LOAD OF INTERCONNECTED ACCESSORY OR INTERVENING SPACES. <br />BCE ENGINEERS <br />2009 EDITION - AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) Al17.1 <br />SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE OCCUPANCY CLASSIFICATION OF THAT SPACE. IN ADDITOIN, THE MOST RESTRICTIVE PROVISIONS OF CHAPTER 9 <br />1004.1.2 <br />AREA WITHOUT FIXED SEATING. THE NUMBER OF OCCUPANTS SHALL BE COMPUTED AT THE RATE OF ONE OCCUPANT PER UNIT OF AREA AS PRESCRIBED IN TABLE 1004.5 <br />2018 EDITION - INTERNATIONAL MECHANICAL CODE (iMC) <br />THAT APPLY TO THE NONSEPARATED OCCUPANCIES SHALL APPLY TO THE TOTAL NONSEPARATED OCCUPANCY AREA. <br />1004.3 <br />POSTING OF OCCUPANT LOAD, EVERY DOOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS <br />2018 EDITION - INTERNATIONAL FIRE CODE/NFPA (IFC) <br />508.3.2 ALLOWABLE BUILDING AREA AND HEIGHT. THE ALLOWABLE BUILDING AREA AND HEIGHT OF THE BUILDING OR PORTION THEREOF SHALL BE BASED ON THE MOST RESTRICTIVE <br />PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. <br />2018 EDITION -UNIFORM PLUMBING CODE (UPC) <br />ALLOWANCES FOR THE OCCUPANCY, GROUPS UNDER CONSIDERATION FOR THE TYPE OF CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION 503.1. <br />1004.6 <br />MULTIPLE OCCUPANCIES. WHERE TWO OR MORE OCCUPANCIES UTILIZE PORTIONS OF THE SAME MEANS OF EGRESS SYSTEM, THOSE EGRESS COMPONENTS SHALL MEET THE MORE <br />STRINGENT REQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED. <br />STATE CODES: <br />TYPES OF CONSTRUCTION ] C CAA �� <br />2018 EDITION - WASHINGTON STATE BUILDING CODE WAC 51-50 <br />1005.3.2 <br />OTHER EGRESS COMPONENTS - EXCEPTIONS: 1. FOR OTHER THAN GROUP H & 1-2 OCCUPANCIES, THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN <br />2018 EDITION - WASHINGTON STATE ENERGY CODE WAC 51-11C; SEE SHT G0.04 <br />TABLE 601: FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS. TYPE V-B CONSTRUCTION: NO BUILDING ELEMENTS ARE REQUIRED TO HAVE FIRE -RESISTANCE RATINGS. <br />STAIRWAYS SHALL BE CALCULATED BY (MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.15 INCH - IN BUILDINGS <br />EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM - AND AN EMERGENCY VOICE/ ALARM COMMUNICATION SYSTEM <br />TABLE 602: FIRE RESISTANCE RATING OF EXTERIOR WALLS = 0-HR, AT TYPE II-B CONSTRUCTION WHERE SEPARATION DISTANCE TO PROPERTY LINE AND ASSUMED PROPERTY LINES ARE <br />1005.4 <br />CONTINIUTY. THE MINIMUM WIDTH OR REQUIRED CAPACITY OF THE MEANS OF EGRESS REQUIRED FROM ANY STORY OF A BUILDING SHALL NOT BE REDUCED ALONG THE PATH OF <br />ALTERATION m LEVEL 2 OEBC 4) <br />GREATER THAN 10'. ( SEE EGRESS PLAN). SEPARATION DISTANCE TO PROPERTY LINE AND ANY ASSUMED PROPERTY LINES ARE GREATER THAN 10'. <br />EGRESS TRAVEL UNTIL ARRIVAL AT THE PUBLIC WAY. <br />LEVEL 2 ALTERATIONS. INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE <br />1005.5 <br />DISTRIBUTION( OF MINIMUM WIDTH & REQUIRED CAPACITY. WHERE MORE THAN ONE EXIT, OR ACCESS TO MORE THAN ONE EXIT, IS REQUIRED, THE MEANS OF EGRESS SHALL BE <br />_ <br />INSTALLATION OF ANY ADDITIONAL EQUIPMENT. LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7 FOR LEVEL 1 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 8. <br />FIRE AND SMOKE PROTECTION (IBC CHAPTER 7 <br />o <br />CONFIGURED SUCH THAT THE LOSS OF ANY ONE EXIT, OR ACCESS TO ONE EXIT, SHALL NOT REDUCE THE AVAILABLE CAPACITY OR WIDTH TO LESS THAN 50 /o OF THE REQUIRED <br />1: <br />CAPACITY OR WIDTH. <br />FIRE PROTECTION YE CC 70 <br />718.1 FIREBLOCKING - FIREBLOCKING SHALL BE INSTALLED IN COMBUSTIBLE CONCEALED LOCATIONS.: <br />WALLS; VERTICALLY AT THE CEILING <br />1006.2.1 <br />EGRESS BASED ON OCCUPANT LOAD S COMMON PATH OF EGRESS TRAVEL DISTANCE. TWO EXITS OR EXIT ACCESS DOORWAYS FORM ANY SPACE SHALL BE PROVIDED WHERE THE <br />s WALLS; HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (PARALLEL ROWS OR STAGGERED STUDS) <br />DESIGN OCCUPANT LOAD OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1. <br />ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED. <br />718.2.1 FIREBLOCKING MATERIALS: FIREBLOCKING SHALL CONSIST OF THE FOLLOWING MATERIALS: <br />2-INCH NOMINAL LUMBER <br />1007.1.1 <br />TWO EXITS OR EXIT ACCESS DOORWAYS - EXCEPTIONS: 2. WHERE A BUILDING IS EQUIPPED THOUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM - THE SEPARATION DISTANCE SHALL <br />1/2" GWa <br />BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. <br />ACCESSIBILITY HEBC 7 ) <br />A FACILITY THAT IS ALTERED SHALL COMPLY WITH THE APPLICABLE PROVISIONS IN SECTIONS 705.1.1 - 705.1.14 AND CHAPTER 11 OF THE IBC UNLESS IT IS TECHNICALLY INFEASIBLE. WHERE COMPLIANCE <br />BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER <br />- UNFACED FIBERGLASS INSULATION <br />1010.1.2 <br />DOOR SWING. EGRESS DOORS SHALL BE OF THE PIVOTED OR SIDE -HINGED SWINGING TYPE. <br />WITH THIS SECTION IS TECHNICALLY INFEASIBLE, THE ALTERATION SHALL PROVIDE ACCESS TO THE MAXIMUM EXTENT THAT IS TECHNICALLY FEASIBLE. <br />1013.4 <br />RAISED CHARACTER & BRAILLE EXIT SIGNS. A SIGN STATING EXIT IN VISUAL CHARACTERS; RAISED CHARACTERS & BRAILLE & COMPLYING WITH !CC A117.1 SHALL BE PROVIDED <br />WHERE IT IS TECHNICALLY INFEASIBLE TO ALTER EXISTING TOILET AND BATHING ROOMS TO BE ACCESSIBLE, AN ACCESSIBLE FAMILY OR ASSISTED USE TOILET OR BATHING ROOM. CONSTRUCTED IN <br />FIREFLOW REQUIREMENTS ([EC APPENDIX )® <br />ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY OR RAMP, AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. <br />ACCORDANCE WITH SECTION 1109.2.1 OF THE IBC IS PERMITTED. THE FAMILY OR ASSISTED -USE TOILET OR BATHING ROOM SHALL BE LOCATED ON THE SAME FLOOR AND IN THE SAME AREA AS THE <br />NO CHANGE TO EXISTING FIDE FLOW REQUIREMENTS OR CAPACITY <br />1016.2 <br />, <br />EXIT ACCESS -EGRESS THRU INTERVENING SPACES. 2, EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THRU ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE <br />- <br />EXISTING TOILET OR BATHING ROOMS. AT THE INACCESSIBLE TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST FAMILY OR ASSISTED USE TOILET ROOM <br />SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE ACCESSORY TO ONE OR THE OTHER. 5. EGRESS SHALL NOT PASS THRU KITCHENS, STORAGE ROOMS, CLOSETS OR <br />OR BATHING ROOM SHALL BE PROVIDED. <br />INTERIOR FINISHES ([ C CHAPTER : <br />SPACES USED FOR SIMILAR PURPOSES. <br />NO WORK REQUIRED - EXISTING TOILET FACILITES FEET ACCESSIBILITY REQUIREMENTS <br />TABLE 803.13 MAXIMUM ALLOWABLE FLAME SPREAD, FOR {CROUP B & E OCCUPANCY, SPRINKLERED: <br />1017.2 <br />EXIT ACCESS TRAVEL DISTANCE - LIMITATIONS. EXIT ACCESS TRAVEL DISTANCE SHALL NOT EXCEED THE VALUES GIVEN IN TABLE 1017.2. GROUP A, E F®�I w1 SPRINKLERS � 250 FT <br />( ) <br />iNT EXIT STAIRWAYS, RAMPS, EXIT PASSAGEWAYS CLASS B - CLASS C PERMITTED PER FOOTNOTES A,B. <br />PLUMBING ]E C 8101 <br />CORRIDORS & ENCLOSURE FOR EXIT ACCESS STAIRWAYS, RAMPS CLASS C (FLAME SPREAD 76-200) <br />9440 REGISTERED <br />ROOMS & ENCLOSED SPACES CLASS C (FLAME SPREAD 76-200) <br />ACCESSIBILITY <br />(IBC CHAPTER 1 <br />ARCHITECT . <br />WHERE THE OCCUPANT LOAD OF THE STORY" IS INCREASED BY MORE THAN 20 PERCENT, PLUMBING FIXTURES FOR THE STORY SHALL BE PROVIDED IN QUANTITIES SPECIFIED IN THE INTERNATIONAL <br />PLUMBING CODE BASED ON THE INCREASED OCCUPANT LOAD. NOT REQUIRED - PROJECT DOES NOT INCREASE OCCUPANT LOAD <br />1 <br />TABLE 803.13 MAXIMUM ALLOWABLE FLAME SPREAD, FOR GROUP F OCCUPANCY, SPRINKLERED: <br />1104.4 <br />AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT EACH ACCESSIBLE STORY AND MEZZANINE IN MULTI-LEVF_L BUILDINGS AND FACILITIES." <br />z,r <br />, �...� <br />INT EXIT STAIRWAYS, RAMPS, EXIT PASSAGEWAYS CLASS C (FLAME SPREAD 76-200) <br />1 � <br />ENERGY CONSERVATION IE 11 <br />CORRIDORS & ENCLOSURE FOR EXIT ACCESS STAIRWAYS, RAMPS CLASS C (FLAME SPREAD 76-200) <br />ANDREW M H r UNG <br />STATE OF WA H9IN0TON <br />ROOMS & ENCLOSED SPACES CLASS C (FLAME SPREAD 76-200) <br />LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES ARE PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE <br />INTERNATIONAL ENERGY CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE. THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY <br />FIRE PROTECTIONSYSTEMS (IBC CHAPTER!): <br />CONSERVATION CODE OR INTERNATIONAL RESIDENTIAL CODE AS THEY (RELATE TO NEW CONSTRUCTION ONLY. <br />906.1 WHERE REQUIRED. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ALL OF THE FOLLOWING LOCATIONS: <br />1. IN GROUP A, B, E, F, H, 1, M, R-1, R-2, R-4 AND S OCCUPANCIES. <br />DEFERREDSUBMITTALS: <br />3. IN AREAS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED, USED OR DISPENSED. <br />EGRESS DIAGRAML <br />THE FOLLOWING BIDDER DESIGNED SYSTEMS ARE TO BE SUBMITTED EITHER SEPARATELY FOR PERMIT OR A DEFEERED SUBMITTAL, FOR REVIEW AND APPROVAL, BY THE CONTRACTOR AFTER NTP AND <br />6. SPECIAL HAZARD AREAS, INCLUDING BUT NOT LIMITED TO LABORATORIES, COMPUTER ROOMS AND GENERATOR ROOMS, WHERE REQUIRED BY THE FIRE CODE OFFICIAL. <br />PRIOR TO ANY WORK BEGINNING ON THESE SYSTEMS: <br />SEE FLOOR PLANS FOR PORTABLE FIRE EXTINGUISHER LOCATIONS. <br />[F] TABLE 906.3.(1) AT LIGHT HAZARD OCCUPANCIES: <br />1. PATH OF EXIT TRAVEL TO BE IDENTIFIED BY EXITS SIGNS, PER ISC1013.1 <br />DEFERRED SUBMITTALS: <br />MINIMUM RATED SINGLE EXTINGUISHER = 2-A (2 UNITS OF A) MAXIMUM FLOOR AREA PER UNIT A = 3,000 SQFT <br />REQUIRED EXIT/DOORS ONLY ARE IDENTIFIED <br />MAXIMUM FLOOR AREA FOR EXTINGUISHER = 11,250 SQFT MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET <br />- SEE ELECTRICAL DWGS FOR EXIT SIGNAGE. <br />1. FIRE SPRINKLER 2. FIRE ALARM 3. ELECTRICAL <br />907 FIRE ALARM DETECTION SYSTEM, INCLUDING SMOKE DETECTORS AND STROBE ALARMS (ANNUNCIATOR PANEL AND KNOX BOX ACCESS) REQUIRED. <br />2. FIRE EXTINGUISHER LOCATIONS SHOWN ON FLOOR PLAN SHEET <br />THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL REVIEW AND COORDINATE SUBMITTAL DOCUMENTS FOR ALL DEFERRED SUBMITTALS PREPARED BY OTHERS. <br />[F] 915A GENERAL, CARBON MONOXIDE DETECTION SHALL BE INSTALLED IN NEW BUILDINGS IN ACCORDANCE WITH SECTIONS 915.1.1 THRU 915.6 <br />SPECIAL [ SP CDO '] 7® o <br />[F] 915.1.1 WHERE REQUIRED. CARBON MONOXIDE DETECTION SHALL BE PROVIDED.... IN CLASSROOMS IN GROUP E OCCUPANCIES IN THE LOCATIONS SPECIFIED IN SECTION 915.2 WHERE ANY OF THE <br />CONDITIONS IN SECTIONS 915.1.2 THRU 915.1.6 EXIST. <br />APPLICABLE IBC INSPECTIONS: MECHANICAL & ELECTRICAL COMPONENTS, ITEMS BY AN APPROVED FABRICATOR. <br />[F] 915.2.3 GROUP E OCCUPANCIES. CARBON MONOXIDE ALARM SIGNALS SHALL BE AUTOMATICALLY TRANSMITTED TO AN ON -SITE LOCATION THAT IS STAFFED BY SCHOOL PERSONNEL <br />DIAGRAMEGRESS <br />Name <br />P r ®] e c t_ <br />USE OCCUPANCY ([ C C IAPTER ): <br />ROOM NAME <br />150 SF : B <br />SNP -ISLE TECH SKILLS CENTER <br />PER 302.1 EDUCATION (EXISTING) E <br />OCCUPANT LOAD <br />1/100 _ 2 <br />AREA AND OCCUPANCY TYPE <br />WELDING SHOP REMODEL <br />VOCATIONAL SHOPS (EXISTING) F-1 <br />FACTOR AND TOTAL <br />1 1 <br />NO. OF REQD EXITS (AND <br />c I I e n t_ <br />OFFICES (EXISTING) B <br />STORAGE (EXISTING) S-1 <br />OCCUPANT LOAD EXITS PROVIDED) <br />MUKILTEO SCHOOL DISTRICT NO. 6 <br />(TABLE 1004.1.1) <br />PROJECT SCOPE DOES NOT CHANGE USE OR OCCUPANCY TYPE <br />REQUIRED EXIT FROM <br />I ®c a t I o n_ <br />INDIVIDUAL ROOM WITH <br />EVERT, WA <br />ALLOWABLE E[G T, WONG AREA & SET BACKS (IBC CHAPTER <br />OCCUPANT LOAD <br />DATA: <br />EXIT DISCHARGE <br />BUILDING PROJECT SCOPE DOES NOT CHANGE EXISTING BUILDING AREA <br />ACTUAL OCCUPANT LOAD <br />THIS PROJECT CONSISTS OF A PARTIAL INTERIOR REMODEL IN BUILDING 2 - AN EXISTING, FULLY SPRINKLERED BUILDING OF TYPE V-B CONSTRUCTION. <br />OCCUPANT LOAD <br />p MAXIMUM OCCUPANT LOAD <br />TABLES 504.3 / 504.4 / 506.2: ALLOWABLE BUILDING HEIGHT (PER IBC, w/ AUTOMATIC SPRINKLER SYSTEM INCREASE): <br />AT EXIT DISCHARGE CALCULATED AS CLEAR WIDTH OF THE <br />THE ALLOWABLE HEIGHT & AREA PROVIDED BELOW ASSUMES NON -SEPARATED USES, USING GROUP T-l' REQUIREMENTS AS THE MOST RESTRICTIVE OCCUPANCY. <br />DOOR (NOMINAL WIDTH MINUS 2 <br />Project No. 20'I 7.000 <br />INCHES), DIVIDED BY 0.15 INCHES PER <br />CONSTRUCTION TYPE ALLOWABLE HEIGHT (T 504.3) ALLOWABLE STORIES (T504:4) ALLOWABLE AREA (T506.2) <br />OCCUPANT, PER IBC SECTION 1005.3.2, <br />CODE ANALYSIS <br />TYPE V-B (FULLY SPRINKLERED) 60'- 0" (S) 2 STORIES (S) (F-1) 34,000 SF (S1) <br />EXCEPTION 1. <br />& EGRESS PLAN <br />EXISTING: FROM ESTABLISHED GRADE PLANE <br />DISTANCE: 250° <br />BLDG 2 20' - 0" 1 STORY SEE CALCULATION BELOW <br />MAX ALLOWED TO CLOSEST EXIT = 250' - - - - ®- - ®- <br />MAX <br />� J�- <br />EXISTING EXIT DOOR DESIGNATION 0 <br />BLDG FRONTAGE CALCULATION BLDG AREA MODIFICATION BLDG AREA CONFIRMATION <br />EXISTING 0-RATED CORRIDOR <br />If = [ (F / P) - 0.25 ] x (W / 30) ONE-STORY, (F-1), TYPE V-B FLOOR AREA + HORIZONTAL PROJECTION = <br />(T1018.1) &/OR HALLWAY, AS <br />If=[(822/822)-0.25]x(29.5/30) Aa=[At+(Ns xIf) ] 26,215SF+10,680SF=36,895SF <br />INDICATED <br />If = 0.73 Aa = [ 34,000 + ( 8,500 x 0.73) ] 40,205 > 36,895 - OK <br />Aa = 40,205 SF ALLOWABLE AREA <br />EXISTING WORK, NO CHANGE IN <br />OCCUPANCY <br />GROSS AREA ANALYSIS: <br />1ST FLOOR 26,215 SF <br />SUBTOTAL / BLDG 26,215 SF = TOTAL EXISTING GROSS BLDG .AREA <br />HORIZ PROJECTIONS: 10,680 SF <br />TOTAL: 36,895 SF = TOTAL EXISTING ROOF OVERHANGS & CANOPIES <br />I� <br />EXISTING <br />PROJECT <br />NORTH <br />i I, = 60'-0" %JJ <br />ORIGINAL SHEET IS 30" x 42" <br />copyright 2020 <br />all. rights reserved <br />EGRESS DIAGRAM <br />Issued <br />PERMIT 02 APR 21 <br />r a v l s l o n- <br />