Laserfiche WebLink
GENERAL NOTES FOR LIGHTING FIXTURE SCHEDULE <br />1, SEE DRAWINGS FOR EMERGENCY LIGHTING FIXTURES. <br />2. FIXTURE TYPES LISTED ARE TO INDICATE THE TYPE OF STYLE, LAMPING CHARACTERISTICS AND MOUNTING REQUIRED TO FACILITATE THE DESIGN. OTHER FIXTURE MANUFACTURERS <br />MEETING THE LIGHT FIXTURE TYPE CRITERIA ARE ACCEPTABLE UPON EVALUATION BY THE ENGINEER. <br />LIGHTING I <br />DELIVERED <br />DESIGNATION FIXTURE DESCRIPTION MANUFACTURERIMODEL # LAMPS LUMENS V W MOUNTING & REMARKS <br />PL1 LED HIGH BAY FIXTURE COLUMBIA #LLHV4-35—H—W—ST—ED—U—SFA LED 21054 277 194 INSTALL AT +16'-0" AFF, <br />PL2 LED PENDANT MOUNT FIXTURE LUMINAIRE LED VPF12-4FT—MIN10-50W-35— LED 4840 277 '' 50 INSTALL AT +10' 0" AFF. <br />MVOLT OP—BLK <br />ELECTRICAL SPECIFICATIONS <br />SECTION 26 00 00 — ELECTRICAL GENERAL CONDITIONS <br />0 THE ELECTRICAL CONTRACTOR SHALL CONFORM TO THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND RELATED WORK IN OTHER DIVISIONS FOR ALL WORK IN DIVISION 26, 27 AND 26. <br />0 THE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE APPLICABLE STANDARDS AND CODES OF THE FOLLOWING: ASTM, NBFU, NEC, WAC, NESC, NEMA, NFPA, U.L., IPCEA, CBM, ETL. <br />0 THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS AND INSPECTIONS REQUIRED BY LAWS, ORDINANCES AND RULES GOVERNING WORK. <br />0 THE CONTRACTOR SHALL MAINTAIN A SET OF AS -BUILT DRAWINGS. <br />0 THE CONTRACTOR SHALL PROVIDE A WRITTEN WARRANTY OF WORKMANSHIP FOR A 12 MONTH PERIOD. <br />0 SHOP DRAWINGS AND OPERATION AND MAINTENANCE MANUALS SHALL BE SUBMITTED IN ACCORDANCE WITH DIVISION 1 SPECIFICATIONS. <br />SECTION 26 0519 — WIRES AND CABLES <br />0 ALL WIRING SHALL BE COPPER THW OR THHN. <br />0 MC CABLE MAY BE USED FOR BRANCH CIRCUITS UP TO 30 AMPS. <br />0 CONDUCTORS SHALL BE TESTED WITH A "MEGGER" TYPE TESTER. FEEDERS SHALL BE CHECKED TO ENSURE PHASE ROTATIONS FOR MOTORS AND EQUIPMENT. <br />SECTION 26 05 26 — GROUNDING <br />0 A GROUNDING SYSTEM SHALL BE PROVIDED FOR NEUTRAL GROUND AND EQUIPMENT GROUND AS REQUIRED BY CODE. <br />0 PROVIDE GROUND WIRE IN ALL CONDUITS. <br />0 METAL INTERNAL PIPING SHALL BE GROUNDED. <br />SECTION 26 05 32 — OUTLETS AND PULL BOXES <br />0 OUTLET AND PULL :BOXES SHALL BE PRESSED STEEL, ZINC COATED, 4" SIZE MINIMUM. <br />0 ALL WORK IN THIS SECTION SHALL BE COORDINATED WITH OTHER TRADES TO PREVENT CONFLICTS: <br />0 DEVICE MOUNTING HEIGHTS SHALL BE AS FOLLOWS: SWITCHES — 4 FEET; RECEPTACLES -13 INCHES; OTHER DEVICES AS NOTED ON PLANS OR IN OTHER SECTIONS OF THE SPECIFICATIONS. <br />SECTION 26 05 33 — RACEWAY <br />0 ALL RACEWAYS SHALL BE GRS, IMC, OR EMT UNLESS NOTED OTHERWISE. <br />0 FLEXIBLE CONDUITS SHALL BE PERMITTED IN 6 FOOT LENGTHS TO MOTORS AND LAY —IN LIGHT FIXTURES. <br />SECTION 26 27 26 — SWITCHES AND RECEPTACLES <br />0 SWITCHES SHALL BE SPECIFICATION GRADE, QUIET TYPE, WHITE COLOR WITH IMPACT RESISTANT WHITE NYLON PLATES. <br />SECTION 26 50 00 — LIGHTING <br />0 INTERIOR FIXTURES SHALL BE STEEL OR ALUMINUM WITH 300 DEGREES F., BAKED ENAMEL FINISH OR BRUSHED FINISH. <br />0 LUMINAIRE TYPE SHALL BE LED WITH A MINIMUM L70 RATING OF 50,000 HOURS. <br />0 MINIMUM CRI SHALL BE 30. <br />0 DRIVERS SHALL BE RATED FOR 50,000 HOURS AND SELECTED TO MATCH CONTROLS AND BE DIMMING OR STATIC AS REQUIRED. <br />0 OCCUPANCY/VACANCY SENSORS SHALL BE INFRARED WALL MOUNTED TYPE FOR PRIVATE OFFICES AND SMALLER ROOMS. <br />SECTION 27 20 00 - DATA AND VOICE INFRASTRUCTURE <br />0 RACEWAYS FOR TELECOMMUNICATIONS SYSTEMS SHALL BE 1" CONDUIT TO ACCESSIBLE CEILING SPACE, CABLE TRAY, NON CONTINUOUS RACEWAY SYSTEM, OR RACK. <br />0 COVERPLATES FOR TELECOMMUNICATION DEVICES SHALL BE IMPACT RESISTANT WHITE THERMOPLASTIC. <br />0 CABLING TO WORKSTATION, MACHINE AND GENERAL PURPOSE DATA JACKS SHALL BE CATEGORY 6— PLENUM OR NON —PLENUM AS REQUIRED. <br />0 ALL DATA PRODUCT SHALL BE TESTED IN ACCORDANCE TO EIAITIA STANDARDS. <br />0 DATA CABLES AND JACKS SHALL BE LABELED PER OWNER STANDARDS. <br />architect <br />MCGRANAHAN ARCHITECTS <br />mechanical engineer_ <br />BCE ENGINEERS <br />electrical engineer_ <br />ICE ENGINEERS <br />ssued <br />PERMIT 05 APB? 21 <br />i <br />drawn_ <br />Sal <br />checked_ <br />BH <br />g <br />sheet_ <br />ORIGINAL SHEET IS 30" x 42". <br />copyright 2021 <br />all rights reserved <br />