Laserfiche WebLink
I <br />I <br />o. •, T149 <br />m <br />i <br />d tl <br />F9 <br />11p <br />—7-111 EXISTING ELECTRICAL TO BE REMOVED <br />s <br />1 <br />DETAIL/PLAN IDENTIFIER <br />E1.01 <br />1 <br />SECTION IDENTIFIER <br />E1.01 <br />1 <br />E 1.01 ELEVATION IDENTIFIER <br />REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS <br />CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE <br />1 REVISION CALLOUT <br />1 FLAG NOTE CALLOUT <br />1 DEMOLITION NOTE TAG <br />1 EQUIPMENT TAG <br />AHU-01 MECHANICAL EQUIPMENT TAG <br />NORTH ARROW <br />D LOCATION WHERE PICTURE <br />1 WAS TAKEN AND DIRECTION <br />LIGHTING <br />A <br />® \_ DEVICE SUBSCRIPTS <br />LA1-12 a�-(LIGHT FIXTURE TYPE) <br />(SWITCH LEG) <br />(CIRCUIT NUMBER) <br />LIGHTING FIXTURES <br />(REFER TO LIGHTING FIXTURES SCHEDULE <br />FOR ADDITIONAL INFORMATION) <br />STRIP LIGHTING FIXTURE <br />® WALL -MOUNTED LIGHTING FIXTURE <br />Oil EMERGENCY LIGHTING FIXTURES <br />(REFER TO LIGHTING FIXTURES SCHEDULE <br />FOR ADDITIONAL INFORMATION) <br />C <br />DOLE -MOUNTED LIGHTING FIXTURE, QUANTITY OF HEADS <br />AS INDICATED <br />®-O-E] DOUBLE HEAD, POLE -MOUNTED, LIGHTING FIXTURE <br />LIGHTING TRACK WITH FIXTURES <br />SELF-CONTAINED BATTERY -POWERED EMERGENCY <br />LIGHTING FIXTURE <br />EXIT SIGN, UNIVERSAL MOUNTING <br />(SHADED AREA INDICATES DIRECTION ARROWS) <br />EXIT SIGN, WALL -MOUNTED <br />(SHADED AREA INDICATES DIRECTION ARROWS) <br />LIGHTING T L <br />,S SWITCH, AS DEFINED BY SUBSCRIPT <br /># = SWITCH LOCATED WITHIN THE SPACE IT IS CONTROLLING <br />a = SWITCH LOCATED REMOTE FROM THE SPACE IT IS CONTROLLING <br />MW = LINE VOLTAGE THREE-WAY OR FOUR-WAY <br />OSD = OCCUPANCY OR VACANCY SENSOR WITH DIMMER <br />OS = OCCUPANCY SENSOR OR VACANCY SENSOR <br />K = KEYED LH = LIGHTED HANDLE <br />P = PILOT LIGHT T = TIMER <br />SEE SWITCH SCHEDULE FOR ADDITIONAL <br />INFORMATION. <br />REFER TO LIGHTING ZONE CONTROL PLAN FOR <br />OCCUPANCY SENSOR OR VACANCY SENSOR <br />REQUIREMENTS. <br />B <&/� OCCUPANCY SENSOR, CEILING -MOUNTED <br />X WHERE INDICATED, SUBSCRIPT INDICATES TYPE <br />OCCUPANCY SENSOR, WALL -MOUNTED <br />© PHOTOSENSOR <br />1 LIGHTING CONTROL TAG <br />X-X <br />10 FC LIGHT LEVEL SET POINT TAG <br />LCP LIGHTING CONTROL PANEL <br />ILI <br />SWITCH BOARD/SWITCHGEAR <br />PANELBOARD, FLUSH -MOUNTED <br />PANELBOARD, SURFACE -MOUNTED <br />(FRONT) <br />TRANSFORMER <br />MOTOR CONNECTION <br />10 DISCONNECT SWITCH, NON -FUSED <br />IL DISCONNECT SWITCH, FUSED <br />LE ENCLOSED CIRCUIT BREAKER <br />VF VARIABLE FREQUENCEY DRIVE <br />$M MANUAL MOTOR STARTER WITH THERMAL OVERLOADS <br />`Z COMBINATION STARTER/DISCONNECT <br />Z MAGNETIC STARTER <br />EQUIPMENT CONNECTION. CONFIRM CONNECTION WITH <br />EQUIPMENT MANUFACTURER <br />`-'F/S FIRE/SMOKE DAMPER <br />E PUSHBUTTON CONTROLLER <br />(SINGLE OR MULTIPLE BUTTONS) <br />EMERGENCY POWER OFF PUSHBUTTON <br />RECEPTACLES <br />PIA-22 <br />�,__ DEVICE SUBSCRIPTS <br />- q2"GF (CIRCUIT NUMBER) <br />�(AC,GF,WP,IG,CR,TP,USB OR OTHER SUBSCRIPT) <br />(NON-STANDARD MOUNTING HEIGHT) <br />SPECIAL RECEPTACLE <br />DUPLEX RECEPTACLE <br />FOURPLEX RECEPTACLE <br />SPLIT WIRE RECEPTACLE <br />J DROP CORD RECEPTACLE <br />JUNCTION BOX <br />F FURNITURE WALL FEED OUTLET BOX <br />PULL BOX <br />X (WHERE INDICATED, SUBSCRIPT INDICATES PULL BOX NUMBER) <br />HH HANDHOLE <br />(WHERE INDICATED, SUBSCRIPT INDICATES HANDHOLE NUMBER) <br />Ea VAULT <br />(WHERE INDICATED, SUBSCRIPT INDICATES VAULT TYPE) <br />FLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR <br />A BOX TYPE) <br />@A POKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR <br />POKE-THRU TYPE) <br />POWER POLE, FLOOR TO CEILING <br />SURFACE METAL RACEWAY <br />RACEWAY CONCEALED IN -WALL OR IN -CEILING <br />(EXPOSED IN UNFINISHED AREAS) <br />® _ RACEWAY RUN BELOW FLOOR OR BELOW GRADE <br />FLEXIBLE RACEWAY <br />RACEWAY (CIRCLE DENOTES VERTICAL TRANSITION) <br />RACEWAY CONTINUATION <br />RACEWAY STUB WITH BUSHINGS <br />RACEWAY SLEEVE WITH BUSHINGS <br />FIRE STOPPING SLEEVE <br />CABLE TRAY, 12"W x 4°H OVERHEAD, UNLESS <br />OTHERWISE NOTED <br />CABLE TRAY, OVERHEAD LADDER TYPE <br />HOMERUN TO PANEL <br />HA- (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br /># -"--(GAUGE OF WIRE OTHER THAN AWG#12) <br />NUMBER OF CONDUCTORS <br />(GROUND CONDUCTOR) <br />(PHASE CONDUCTORS) <br />(NEUTRAL CONDUCTOR) <br />--- EQUIPMENT ENCLOSURE <br />BUS <br />WIRE <br />—Q TERMINAL / LUG <br />CONNECTION <br />DELTA <br />WYE <br />✓� POWER TRANSFORMER <br />- CURRENT TRANSFORMER <br />p� <br />I I TRANSFER SWITCH <br />I < I <br />CIRCUIT BREAKER, FIXED <br />CIRCUIT BREAKER, DRAWOUT <br />-� DISCONNECT SWITCH <br />FUSED SWITCH <br />FUSE <br />FUSED CUTOUTS <br />ti <br />GF I CIRCUIT BREAKER WITH GROUND FAULT PROTECTION <br />I <br />GT I CIRCUIT BREAKER WITH SHUNT TRIP OPERATOR <br />GF I FUSED SWITCH WITH GROUND FAULT PROTECTION <br />MOTOR CONNECTION <br />G GENERATOR <br />M METERING DEVICE <br />(M = METER) <br />(WH = WATT HOUR METER) <br />(A = AMMETER) <br />(V = VOLTMETER) <br />ST SHUNT TRIP <br />OF GROUND FAULT PROTECTION <br />EHM ELECTRONIC POWER METER <br />SPD SURGE PROTECTIVE DEVICE <br />�— GROUND <br />12,241 AVAILABLE FAULT CURRENT <br />(SYMMETRICAL) TAG <br />225 FEEDER TAG <br />9 I PAD MOUNT TRANSFORMER <br />L�__-J <br />A v 480V <br />I I <br />I I TRANSFORMER <br />L - 2osY <br />120V <br />I 1 <br />I I PANELBOARD MAIN LUGS ONLY <br />I � I <br />I I PANELBOARD - MAIN CIRCUIT BREAKER <br />GROUNDING <br />—G— <br />GROUNDING CONDUCTOR <br />GROUNDING ROD <br />D—� <br />GROUNDING BUSBAR <br />EQUIPMENT GROUNDING CONNECTION <br />GROUNDING STRAP <br />WP <br />DEVICE SUBSCRIPTS (TYPICAL ALL SYSTEMS) <br />+42°' <br />WP, WG OR OTHER SUBSCRIPT) <br />(NON-STANDARD MOUNTING HEIGHT) <br />FF_A­CP1 FIRE ALARM CONTROL PANEL <br />FAAP FIRE ALARM ANNUNCIATOR PANEL <br />NAC NOTIFICATION APPLIANCE CIRCUIT <br />SPEAKER/STROBE COMBINATION, WALL -MOUNTED <br />F SPEAKER/STROBE COMBINATION, CEILING -MOUNTED <br />STROBE ONLY, WALL -MOUNTED <br />STROBE ONLY, CEILING -MOUNTED <br />A <br />BEAM SMOKE DETECTOR - TRANSMITTER <br />BEAM SMOKE DETECTOR - RECEIVER <br />® MANUAL PULL STATION <br />SMOKE DETECTOR <br />G F/ FIRE/SMOKE DAMPER <br />HEAT DETECTOR <br />MAGNETIC DOOR HOLD OPEN DEVICE <br />® FLOW SWITCH <br />TAMPER SWITCH <br />© PRESSURE SWITCH <br />R� RELAY <br />DUCT SMOKE DETECTOR <br />F 10" EXTERIOR BELL - WEATHERPROOF <br />KNOX BOX <br />_ w..�" ; V <br />INTERCOM AND CLOCK, WALL -MOUNTED <br />C <br />DIGITAL CLOCK, WALL -MOUNTED <br />C <br />CLOCK, WALL -MOUNTED <br />G-(WHERE APPLICABLE WIRE GUARD) <br />I <br />SPEAKER, CEILING -MOUNTED <br />IP "--(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE) <br />I <br />SPEAKER, WALL -MOUNTED <br />IP -(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE) <br />[D< <br />SPEAKER EXTERIOR RATED, WALL -MOUNTED <br />IP -(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE) <br />B <br />EXTERIOR BELL, WALL -MOUNTED <br />Cs <br />CALL OR PANIC SWITCH, WALL -MOUNTED <br />$v <br />VOLUME CONTROL, WALL -MOUNTED <br />$DB <br />DOORBELL, WALL -MOUNTED <br />CLASSROOM I I L SYSTEM <br />Av x AUDIO VISUAL INPUT PLATE, WALL -MOUNTED <br />�-(1 <br />= HDMI, VGA W/AUDIO) <br />(2 = HDMI, VGA W/AUDIO & USB) <br />CP <br />CONTROL PANEL, WALL -MOUNTED <br />AUDIO PLATE/,AMPLIFIER, WALL -MOUNTED <br />AL <br />ASSISTIVE LISTENING OUTPUT, WALL -MOUNTED <br />S <br />SPEAKER (1x2 OR 2x2), IN -CEILING <br />S <br />SPEAKER, CEILING -MOUNTED <br />S <br />Imo <br />SPEAKER, WALL -MOUNTED <br />-(WHERE <br />APPLICABLE SPEAKER W/ INTEGRATED IR SENSOR) <br />vP <br />VIDEO PROJECTOR, WALL -MOUNTED <br />Av <br />AV EQUIPMENT ENCLOSURE, WALL -MOUNTED <br />F_ 7 <br />Ln <br />Ali EQUIPMENT ENCLOSURE, CEILING -MOUNTED <br />AE <br />AUDIO ENCHANCEMENT, WALL -MOUNTED <br />In <br />AUDIO ENCHANCEMENT, CEILING -MOUNTED <br />--& <br />INFRARED SENSOR, WALL -MOUNTED <br />IR <br />INFRARED SENSOR, CEILING -MOUNTED <br />X <br />DIGITAL 4-PAIR F/UTP DEVICE, WALL -MOUNTED <br />(X=REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />rX� <br />I- <br />DIGITAL 4-PAIR F/UTP DEVICE, ABOVE CEILING <br />(X=REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />AUDIO VISUAL INPUT P - U LATE, WALL MOUNTED <br />AV (5 = DUAL HDMI & AUDIO) <br />X (6 = HDMI,VGA & AUDIO) <br />A AUDIO 3. SMM INPUT, WALL -MOUNTED <br />AX AUX AUDIO L/R XLR INPUT, WALL -MOUNTED <br />MIC, AUX, AUDIO INPUT, WALL -MOUNTED <br />SP X SOUND INTERFACE PLATE, WALL -MOUNTED <br />(X = DENOTES CONFIGURATION TYPE) <br />TP X TOUCH PANEL CONTROLLER, WALL -MOUNTED <br />�-(X = DENOTES SCREEN SIZE) <br />Rv REMOTE VOLUME CONTROLLER, WALL -MOUNTED <br />DUAL MICROPHONE INPUT, WALL -MOUNTED <br />M HANGING MICROPHONE, CEILING -MOUNTED <br />s SPEAKER, CEILING -MOUNTED <br />SL LOUDSPEAKER, WALL -MOUNTED <br />X (1 = 12", 2-WAY LOUDSPEAKER) <br />(2 = 15", 2-WAY LOUDSPEAKER) <br />(3 = 15", 3-WAY LOUDSPEAKER) <br />SUBWOOFER, WALL -MOUNTED <br />sA SPEAKER LINE ARRAY, WALL -MOUNTED <br />S MONITOR SPEAKER OUTPUT, WALL -MOUNTED <br />AL ASSISTED LISTENING OUTLET, WALL -MOUNTED <br />WIRELESS MIC ANTENNA, CEILING -MOUNTED <br />Rs RS-232 CONTROL, EQUIPMENT CONNECTION <br />RL RELAY CONTROL, EQUIPMENT CONNECTION <br />vP VIDEO PROJECTOR, CEILING -MOUNTED <br />vP VIDEO PROJECTOR, WALL -MOUNTED <br />'_vJ VIDEO PROJECTOR WITH SCISSOR LIFT <br />FPD FLAT PANEL DISPLAY, WALL -MOUNTED <br />Ds DIGITAL SIGNAGE MONITOR, WALL -MOUNTED <br />WBX RECESSED WALL BOX, WALL -MOUNTED <br />(X = DENOTES TYPE) <br />B AV EQUIPMENT BOX, TABLE -MOUNTED <br />X (X = DENOTES TYPE) <br />PB v AV RACK JUNCTION BOX, WALL -MOUNTED <br />AUDIOIS LONE -LINE <br />DIGITAL AUDIO VIDEO SIGNAL <br />- - - - <br />ANALOG AUDIO SIGNAL <br />---- <br />CONTROL SIGNAL/POWER <br />LINE INTERSECTION MARK <br />Q- <br />PARALLEL AUDIO CONNECTION <br />1 <br />ON PAGE DESTINATION <br />Device I INPUT/OUTPUT PLATE <br />BPBC HDMI <br />vcA <br />AUDfO <br />(DEVICE ID) <br />(CONNECTOR TYPES) <br />TITLE 1 <br />TITLE z <br />EQUIPMENT BLOCK <br />1 3 <br />(EQUIPMENT TYPE & MODEL NO.) <br />2 4 <br />(INPUT/OUTPUTS) <br />_> <br />SIGNAL FLOW <br />EQUIPMENT CONNECTION, PRE -TERM <br />- <br />EQUIPMENT CONNECTION, FIELD TERM <br />j} <br />ANTENNA CONNECTION <br />SECURITY VIDEOSYSTEM <br />SECURITY VIDEO CAMERA MOUNTING <br />ERNDANT MOUNTED) <br />Y(R = ROOF PARAPET MOUNTED) <br />ffflll(W = WALL -MOUNTED W/BRACKET) <br />VIDEO SECURITY CAMERA ID <br />#---(WHERE APPLICABLE REPRESENTS THE CAMERA # OR TYPE) <br />C CAMERA, CEILING -MOUNTED <br />C CAMERA, WALL -MOUNTED <br />C CAMERA, WALL -MOUNTED W/BRACKE o <br />X (180 = 180 DEGREE VIEW CAMERA) <br />(360 = 360 DEGREE VIEW CAMERA) <br />C 360 DEGREE CAMERA, CEILING -MOUNTED <br />sM SECURITY MONITOR, WALL -MOUNTED <br />TELECOMMUNICATIONS., <br />DRAWINGIm <br />-". <br />j.m",f"'r"«','a/"•<"3z.'Ys'9'.3 <br />ESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />'O <br />EO.02 <br />ELECTRICAL ABBREVIATIONS moAL NOTES <br />-}^.`if.,far <br />4LL . ONE MTD I I..R <br />"1 <br />TELECOMMUNICATIONS <br />.xp�3 <br />S:*��.zJ..f1 <br />" <br />BCOVERaPLATE)TELECOM <br />II... <br />LOW -VOLTAGE ROUGH -IN SCHEDULES <br />II <br />:OL'DEVICE) <br />ED2 <br />BASEMENT <br />AUDITORIUM DEMOLITION <br />LIGHTING PLAN <br />. <br />(AC = ABOVE COUNTER DEVICE) <br />ED3.01 <br />AUDITORIUM BASEMENT POWERDEMOLITIONPLAN <br />SURFACE <br />P = WALL -MOUNTED At DATA DEVICE) <br />I <br />I I DEMOLITION <br />ABOVE CEILING TELECOMMUNICATIONS DEVICE <br />ED6.01 <br />AUIDITORIUM BASEMENT TELECOM DEMOLITION <br />'4t�r �.ds...`S s1+5- ;Sn,.„�,ti.�'d.,.. •Ari'. ;,.J{`dT`44Ex y. 3.}$�^ '=ice 3".... <br />I� <br />I mil!I <br />� ; BASEMENT � I <br />AUDITORIUM PLAN <br />•iTi W Y,vx.k h"t d t X 'hyyr... .� _i. f i 5 :fti 'f S'S" j` <br />I <br />= WIRELESS ACCESS DEVICE) <br />I(WAP I <br />AUDITORIUM <br />VIDEO CAMERA) <br />DO I B PLAN <br />.n a <br />�� <br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD <br />E&01 <br />y <br />I <br />i BASEMENT <br />UM <br />aS <br />+� <br />` I DETAILS <br />TELECOM <br />iOILOW-VOLTAGE ENLARGED PLANS <br />11-d 10 Q"ice` <br />rzF{' S^ }.�'a'` �^ s�.s. .}^`ii,�S, y�' �.. ? C�,.A <br />�i <br />.,a RACK { <br />TWO -POST EQUIPMENT <br />� , <br />TELECOMI I LTAGENLARGED D DETAILS <br />Ck <br />8. <br />II <br />D PLANS ANDDETAILS <br />■ <br />DOUBLE -SIDED VERTICAL MANAGEMENT <br />E901 <br />; ONE -LINE DIAGRAMS <br />ELECTRICAL AND <br />DOUBLE-SIDED MANAGEMENT <br />I f <br />.I <br />II <br />t <br />I <br />I <br />FLOOR 7 I I is <br />MOUNTED <br />WALL-MOUNTEDENCLOSURE <br />110 BLOCK WITH LEGS <br />66 BLOCK <br />i <br />Y I- �%ih".I <br />ACP ACCESS CONTROL PANEL <br />CREDENTIAL/CARD READER <br />(CR = CARD READER, WALL -MOUNTED) <br />C (CR/P = CARD READER W/PIN, WALL -MOUNTED) <br />(CR/M = CARD READER, MULLION -MOUNTED) <br />7 DOOR POSITION SWITCH <br />El DOOR ENTRY STATION, WALL -MOUNTED <br />2S1 DOOR MASTER STATION, DESK TOP <br />SECURITY BUTTONS/SWITCH, WALL -MOUNTED <br />S (AO = AUTO OPERATOR) <br />XX (DR = DOOR RELEASE) <br />(LD = LOCKDOWN) <br />(KS = KEYED SWITCH) <br />(PB = PANIC/DURESS) <br />SECURITY BUTTONS, UNDER DESK MOUNTED <br />(DR = DOOR RELEASE) <br />XX(LD = LOCKDOWN) <br />(PS = PANIC/DURESS) <br />R REQUEST TO EXIT DETECTOR, WALL -MOUNTED <br />R REQUEST TO EXIT DETECTOR, CEILING -MOUNTED <br />REQUEST TO EXIT, INTEGRAL MICRO SWITCH <br />-® REQUEST TO EXIT BUTTON, WALL -MOUNTED <br />S HORN, WALL -MOUNTED <br />a A, <br />STROBE, WALL -MOUNTED <br />®9s v STROBE/HORN, CEILING -MOUNTED <br />B <br />PS DOOR HARDWARE POWER SUPPLY (DIV 08) <br />X (X = QUANTITY OF DOORS) <br />EL DOOR HARDWARE POWER SUPPLY (DIV 08) <br />(EL = ELECTRIFIED LOCKSET/EXIT DEVICE) <br />(ES = ELECTRIFIED STRIKE) <br />(ML = ELECTRIFIED MAGNETIC LOCK) <br />(MH = ELECTRIFIED MAGNETIC HOLD OPEN) <br />" "� aR I...' ;♦,I;` +�' ti... I {._ ` t I �a .i > ¢ ; ` Iz El <br />IDP INTRUSION DETECTION PANEL <br />KEYPAD, WALL -MOUNTED <br />K <br />S PIR MOTION DETECTOR, WALL -MOUNTED <br />S 360 DEGREE PIR/MOTION DETECTOR, CEILING -MOUNTED <br />P PHOTO -BEAM DETECTOR, WALL -MOUNTED <br />S DOOR POSITION SWITCH <br />T TEMPERATURE PROBE <br />G GLASS BREAK DETECTOR, CEILING -MOUNTED <br />A AUDIO SENSOR, WALL -MOUNTED <br />Bs RESCUE ASSISTANCE BASE STATION, WALL -MOUNTED <br />RA CS RESCUE ASSISTANCE CALL STATION, WALL -MOUNTED <br />NOT ALL SYMBOLS MAY APPEAR ON THE DRAWINGS <br />iBi <br />IA <br />1 <br />Is <br />3/27/2019 1:29:18 PM <br />