I
<br />I
<br />o. •, T149
<br />m
<br />i
<br />d tl
<br />F9
<br />11p
<br />—7-111 EXISTING ELECTRICAL TO BE REMOVED
<br />s
<br />1
<br />DETAIL/PLAN IDENTIFIER
<br />E1.01
<br />1
<br />SECTION IDENTIFIER
<br />E1.01
<br />1
<br />E 1.01 ELEVATION IDENTIFIER
<br />REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS
<br />CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE
<br />1 REVISION CALLOUT
<br />1 FLAG NOTE CALLOUT
<br />1 DEMOLITION NOTE TAG
<br />1 EQUIPMENT TAG
<br />AHU-01 MECHANICAL EQUIPMENT TAG
<br />NORTH ARROW
<br />D LOCATION WHERE PICTURE
<br />1 WAS TAKEN AND DIRECTION
<br />LIGHTING
<br />A
<br />® \_ DEVICE SUBSCRIPTS
<br />LA1-12 a�-(LIGHT FIXTURE TYPE)
<br />(SWITCH LEG)
<br />(CIRCUIT NUMBER)
<br />LIGHTING FIXTURES
<br />(REFER TO LIGHTING FIXTURES SCHEDULE
<br />FOR ADDITIONAL INFORMATION)
<br />STRIP LIGHTING FIXTURE
<br />® WALL -MOUNTED LIGHTING FIXTURE
<br />Oil EMERGENCY LIGHTING FIXTURES
<br />(REFER TO LIGHTING FIXTURES SCHEDULE
<br />FOR ADDITIONAL INFORMATION)
<br />C
<br />DOLE -MOUNTED LIGHTING FIXTURE, QUANTITY OF HEADS
<br />AS INDICATED
<br />®-O-E] DOUBLE HEAD, POLE -MOUNTED, LIGHTING FIXTURE
<br />LIGHTING TRACK WITH FIXTURES
<br />SELF-CONTAINED BATTERY -POWERED EMERGENCY
<br />LIGHTING FIXTURE
<br />EXIT SIGN, UNIVERSAL MOUNTING
<br />(SHADED AREA INDICATES DIRECTION ARROWS)
<br />EXIT SIGN, WALL -MOUNTED
<br />(SHADED AREA INDICATES DIRECTION ARROWS)
<br />LIGHTING T L
<br />,S SWITCH, AS DEFINED BY SUBSCRIPT
<br /># = SWITCH LOCATED WITHIN THE SPACE IT IS CONTROLLING
<br />a = SWITCH LOCATED REMOTE FROM THE SPACE IT IS CONTROLLING
<br />MW = LINE VOLTAGE THREE-WAY OR FOUR-WAY
<br />OSD = OCCUPANCY OR VACANCY SENSOR WITH DIMMER
<br />OS = OCCUPANCY SENSOR OR VACANCY SENSOR
<br />K = KEYED LH = LIGHTED HANDLE
<br />P = PILOT LIGHT T = TIMER
<br />SEE SWITCH SCHEDULE FOR ADDITIONAL
<br />INFORMATION.
<br />REFER TO LIGHTING ZONE CONTROL PLAN FOR
<br />OCCUPANCY SENSOR OR VACANCY SENSOR
<br />REQUIREMENTS.
<br />B <&/� OCCUPANCY SENSOR, CEILING -MOUNTED
<br />X WHERE INDICATED, SUBSCRIPT INDICATES TYPE
<br />OCCUPANCY SENSOR, WALL -MOUNTED
<br />© PHOTOSENSOR
<br />1 LIGHTING CONTROL TAG
<br />X-X
<br />10 FC LIGHT LEVEL SET POINT TAG
<br />LCP LIGHTING CONTROL PANEL
<br />ILI
<br />SWITCH BOARD/SWITCHGEAR
<br />PANELBOARD, FLUSH -MOUNTED
<br />PANELBOARD, SURFACE -MOUNTED
<br />(FRONT)
<br />TRANSFORMER
<br />MOTOR CONNECTION
<br />10 DISCONNECT SWITCH, NON -FUSED
<br />IL DISCONNECT SWITCH, FUSED
<br />LE ENCLOSED CIRCUIT BREAKER
<br />VF VARIABLE FREQUENCEY DRIVE
<br />$M MANUAL MOTOR STARTER WITH THERMAL OVERLOADS
<br />`Z COMBINATION STARTER/DISCONNECT
<br />Z MAGNETIC STARTER
<br />EQUIPMENT CONNECTION. CONFIRM CONNECTION WITH
<br />EQUIPMENT MANUFACTURER
<br />`-'F/S FIRE/SMOKE DAMPER
<br />E PUSHBUTTON CONTROLLER
<br />(SINGLE OR MULTIPLE BUTTONS)
<br />EMERGENCY POWER OFF PUSHBUTTON
<br />RECEPTACLES
<br />PIA-22
<br />�,__ DEVICE SUBSCRIPTS
<br />- q2"GF (CIRCUIT NUMBER)
<br />�(AC,GF,WP,IG,CR,TP,USB OR OTHER SUBSCRIPT)
<br />(NON-STANDARD MOUNTING HEIGHT)
<br />SPECIAL RECEPTACLE
<br />DUPLEX RECEPTACLE
<br />FOURPLEX RECEPTACLE
<br />SPLIT WIRE RECEPTACLE
<br />J DROP CORD RECEPTACLE
<br />JUNCTION BOX
<br />F FURNITURE WALL FEED OUTLET BOX
<br />PULL BOX
<br />X (WHERE INDICATED, SUBSCRIPT INDICATES PULL BOX NUMBER)
<br />HH HANDHOLE
<br />(WHERE INDICATED, SUBSCRIPT INDICATES HANDHOLE NUMBER)
<br />Ea VAULT
<br />(WHERE INDICATED, SUBSCRIPT INDICATES VAULT TYPE)
<br />FLOORBOX (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR
<br />A BOX TYPE)
<br />@A POKE-THRU (WHERE INDICATED, SUBSCRIPT INDICATES FLOOR
<br />POKE-THRU TYPE)
<br />POWER POLE, FLOOR TO CEILING
<br />SURFACE METAL RACEWAY
<br />RACEWAY CONCEALED IN -WALL OR IN -CEILING
<br />(EXPOSED IN UNFINISHED AREAS)
<br />® _ RACEWAY RUN BELOW FLOOR OR BELOW GRADE
<br />FLEXIBLE RACEWAY
<br />RACEWAY (CIRCLE DENOTES VERTICAL TRANSITION)
<br />RACEWAY CONTINUATION
<br />RACEWAY STUB WITH BUSHINGS
<br />RACEWAY SLEEVE WITH BUSHINGS
<br />FIRE STOPPING SLEEVE
<br />CABLE TRAY, 12"W x 4°H OVERHEAD, UNLESS
<br />OTHERWISE NOTED
<br />CABLE TRAY, OVERHEAD LADDER TYPE
<br />HOMERUN TO PANEL
<br />HA- (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER)
<br /># -"--(GAUGE OF WIRE OTHER THAN AWG#12)
<br />NUMBER OF CONDUCTORS
<br />(GROUND CONDUCTOR)
<br />(PHASE CONDUCTORS)
<br />(NEUTRAL CONDUCTOR)
<br />--- EQUIPMENT ENCLOSURE
<br />BUS
<br />WIRE
<br />—Q TERMINAL / LUG
<br />CONNECTION
<br />DELTA
<br />WYE
<br />✓� POWER TRANSFORMER
<br />- CURRENT TRANSFORMER
<br />p�
<br />I I TRANSFER SWITCH
<br />I < I
<br />CIRCUIT BREAKER, FIXED
<br />CIRCUIT BREAKER, DRAWOUT
<br />-� DISCONNECT SWITCH
<br />FUSED SWITCH
<br />FUSE
<br />FUSED CUTOUTS
<br />ti
<br />GF I CIRCUIT BREAKER WITH GROUND FAULT PROTECTION
<br />I
<br />GT I CIRCUIT BREAKER WITH SHUNT TRIP OPERATOR
<br />GF I FUSED SWITCH WITH GROUND FAULT PROTECTION
<br />MOTOR CONNECTION
<br />G GENERATOR
<br />M METERING DEVICE
<br />(M = METER)
<br />(WH = WATT HOUR METER)
<br />(A = AMMETER)
<br />(V = VOLTMETER)
<br />ST SHUNT TRIP
<br />OF GROUND FAULT PROTECTION
<br />EHM ELECTRONIC POWER METER
<br />SPD SURGE PROTECTIVE DEVICE
<br />�— GROUND
<br />12,241 AVAILABLE FAULT CURRENT
<br />(SYMMETRICAL) TAG
<br />225 FEEDER TAG
<br />9 I PAD MOUNT TRANSFORMER
<br />L�__-J
<br />A v 480V
<br />I I
<br />I I TRANSFORMER
<br />L - 2osY
<br />120V
<br />I 1
<br />I I PANELBOARD MAIN LUGS ONLY
<br />I � I
<br />I I PANELBOARD - MAIN CIRCUIT BREAKER
<br />GROUNDING
<br />—G—
<br />GROUNDING CONDUCTOR
<br />GROUNDING ROD
<br />D—�
<br />GROUNDING BUSBAR
<br />EQUIPMENT GROUNDING CONNECTION
<br />GROUNDING STRAP
<br />WP
<br />DEVICE SUBSCRIPTS (TYPICAL ALL SYSTEMS)
<br />+42°'
<br />WP, WG OR OTHER SUBSCRIPT)
<br />(NON-STANDARD MOUNTING HEIGHT)
<br />FF_ACP1 FIRE ALARM CONTROL PANEL
<br />FAAP FIRE ALARM ANNUNCIATOR PANEL
<br />NAC NOTIFICATION APPLIANCE CIRCUIT
<br />SPEAKER/STROBE COMBINATION, WALL -MOUNTED
<br />F SPEAKER/STROBE COMBINATION, CEILING -MOUNTED
<br />STROBE ONLY, WALL -MOUNTED
<br />STROBE ONLY, CEILING -MOUNTED
<br />A
<br />BEAM SMOKE DETECTOR - TRANSMITTER
<br />BEAM SMOKE DETECTOR - RECEIVER
<br />® MANUAL PULL STATION
<br />SMOKE DETECTOR
<br />G F/ FIRE/SMOKE DAMPER
<br />HEAT DETECTOR
<br />MAGNETIC DOOR HOLD OPEN DEVICE
<br />® FLOW SWITCH
<br />TAMPER SWITCH
<br />© PRESSURE SWITCH
<br />R� RELAY
<br />DUCT SMOKE DETECTOR
<br />F 10" EXTERIOR BELL - WEATHERPROOF
<br />KNOX BOX
<br />_ w..�" ; V
<br />INTERCOM AND CLOCK, WALL -MOUNTED
<br />C
<br />DIGITAL CLOCK, WALL -MOUNTED
<br />C
<br />CLOCK, WALL -MOUNTED
<br />G-(WHERE APPLICABLE WIRE GUARD)
<br />I
<br />SPEAKER, CEILING -MOUNTED
<br />IP "--(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE)
<br />I
<br />SPEAKER, WALL -MOUNTED
<br />IP -(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE)
<br />[D<
<br />SPEAKER EXTERIOR RATED, WALL -MOUNTED
<br />IP -(WHERE APPLICABLE IP SPEAKER W/TELECOM DEVICE)
<br />B
<br />EXTERIOR BELL, WALL -MOUNTED
<br />Cs
<br />CALL OR PANIC SWITCH, WALL -MOUNTED
<br />$v
<br />VOLUME CONTROL, WALL -MOUNTED
<br />$DB
<br />DOORBELL, WALL -MOUNTED
<br />CLASSROOM I I L SYSTEM
<br />Av x AUDIO VISUAL INPUT PLATE, WALL -MOUNTED
<br />�-(1
<br />= HDMI, VGA W/AUDIO)
<br />(2 = HDMI, VGA W/AUDIO & USB)
<br />CP
<br />CONTROL PANEL, WALL -MOUNTED
<br />AUDIO PLATE/,AMPLIFIER, WALL -MOUNTED
<br />AL
<br />ASSISTIVE LISTENING OUTPUT, WALL -MOUNTED
<br />S
<br />SPEAKER (1x2 OR 2x2), IN -CEILING
<br />S
<br />SPEAKER, CEILING -MOUNTED
<br />S
<br />Imo
<br />SPEAKER, WALL -MOUNTED
<br />-(WHERE
<br />APPLICABLE SPEAKER W/ INTEGRATED IR SENSOR)
<br />vP
<br />VIDEO PROJECTOR, WALL -MOUNTED
<br />Av
<br />AV EQUIPMENT ENCLOSURE, WALL -MOUNTED
<br />F_ 7
<br />Ln
<br />Ali EQUIPMENT ENCLOSURE, CEILING -MOUNTED
<br />AE
<br />AUDIO ENCHANCEMENT, WALL -MOUNTED
<br />In
<br />AUDIO ENCHANCEMENT, CEILING -MOUNTED
<br />--&
<br />INFRARED SENSOR, WALL -MOUNTED
<br />IR
<br />INFRARED SENSOR, CEILING -MOUNTED
<br />X
<br />DIGITAL 4-PAIR F/UTP DEVICE, WALL -MOUNTED
<br />(X=REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)
<br />rX�
<br />I-
<br />DIGITAL 4-PAIR F/UTP DEVICE, ABOVE CEILING
<br />(X=REPRESENTS THE # OF TELECOMMUNICATIONS MODULES)
<br />AUDIO VISUAL INPUT P - U LATE, WALL MOUNTED
<br />AV (5 = DUAL HDMI & AUDIO)
<br />X (6 = HDMI,VGA & AUDIO)
<br />A AUDIO 3. SMM INPUT, WALL -MOUNTED
<br />AX AUX AUDIO L/R XLR INPUT, WALL -MOUNTED
<br />MIC, AUX, AUDIO INPUT, WALL -MOUNTED
<br />SP X SOUND INTERFACE PLATE, WALL -MOUNTED
<br />(X = DENOTES CONFIGURATION TYPE)
<br />TP X TOUCH PANEL CONTROLLER, WALL -MOUNTED
<br />�-(X = DENOTES SCREEN SIZE)
<br />Rv REMOTE VOLUME CONTROLLER, WALL -MOUNTED
<br />DUAL MICROPHONE INPUT, WALL -MOUNTED
<br />M HANGING MICROPHONE, CEILING -MOUNTED
<br />s SPEAKER, CEILING -MOUNTED
<br />SL LOUDSPEAKER, WALL -MOUNTED
<br />X (1 = 12", 2-WAY LOUDSPEAKER)
<br />(2 = 15", 2-WAY LOUDSPEAKER)
<br />(3 = 15", 3-WAY LOUDSPEAKER)
<br />SUBWOOFER, WALL -MOUNTED
<br />sA SPEAKER LINE ARRAY, WALL -MOUNTED
<br />S MONITOR SPEAKER OUTPUT, WALL -MOUNTED
<br />AL ASSISTED LISTENING OUTLET, WALL -MOUNTED
<br />WIRELESS MIC ANTENNA, CEILING -MOUNTED
<br />Rs RS-232 CONTROL, EQUIPMENT CONNECTION
<br />RL RELAY CONTROL, EQUIPMENT CONNECTION
<br />vP VIDEO PROJECTOR, CEILING -MOUNTED
<br />vP VIDEO PROJECTOR, WALL -MOUNTED
<br />'_vJ VIDEO PROJECTOR WITH SCISSOR LIFT
<br />FPD FLAT PANEL DISPLAY, WALL -MOUNTED
<br />Ds DIGITAL SIGNAGE MONITOR, WALL -MOUNTED
<br />WBX RECESSED WALL BOX, WALL -MOUNTED
<br />(X = DENOTES TYPE)
<br />B AV EQUIPMENT BOX, TABLE -MOUNTED
<br />X (X = DENOTES TYPE)
<br />PB v AV RACK JUNCTION BOX, WALL -MOUNTED
<br />AUDIOIS LONE -LINE
<br />DIGITAL AUDIO VIDEO SIGNAL
<br />- - - -
<br />ANALOG AUDIO SIGNAL
<br />----
<br />CONTROL SIGNAL/POWER
<br />LINE INTERSECTION MARK
<br />Q-
<br />PARALLEL AUDIO CONNECTION
<br />1
<br />ON PAGE DESTINATION
<br />Device I INPUT/OUTPUT PLATE
<br />BPBC HDMI
<br />vcA
<br />AUDfO
<br />(DEVICE ID)
<br />(CONNECTOR TYPES)
<br />TITLE 1
<br />TITLE z
<br />EQUIPMENT BLOCK
<br />1 3
<br />(EQUIPMENT TYPE & MODEL NO.)
<br />2 4
<br />(INPUT/OUTPUTS)
<br />_>
<br />SIGNAL FLOW
<br />EQUIPMENT CONNECTION, PRE -TERM
<br />-
<br />EQUIPMENT CONNECTION, FIELD TERM
<br />j}
<br />ANTENNA CONNECTION
<br />SECURITY VIDEOSYSTEM
<br />SECURITY VIDEO CAMERA MOUNTING
<br />ERNDANT MOUNTED)
<br />Y(R = ROOF PARAPET MOUNTED)
<br />ffflll(W = WALL -MOUNTED W/BRACKET)
<br />VIDEO SECURITY CAMERA ID
<br />#---(WHERE APPLICABLE REPRESENTS THE CAMERA # OR TYPE)
<br />C CAMERA, CEILING -MOUNTED
<br />C CAMERA, WALL -MOUNTED
<br />C CAMERA, WALL -MOUNTED W/BRACKE o
<br />X (180 = 180 DEGREE VIEW CAMERA)
<br />(360 = 360 DEGREE VIEW CAMERA)
<br />C 360 DEGREE CAMERA, CEILING -MOUNTED
<br />sM SECURITY MONITOR, WALL -MOUNTED
<br />TELECOMMUNICATIONS.,
<br />DRAWINGIm
<br />-".
<br />j.m",f"'r"«','a/"•<"3z.'Ys'9'.3
<br />ESENTS THE # OF TELECOMMUNICATIONS MODULES)
<br />'O
<br />EO.02
<br />ELECTRICAL ABBREVIATIONS moAL NOTES
<br />-}^.`if.,far
<br />4LL . ONE MTD I I..R
<br />"1
<br />TELECOMMUNICATIONS
<br />.xp�3
<br />S:*��.zJ..f1
<br />"
<br />BCOVERaPLATE)TELECOM
<br />II...
<br />LOW -VOLTAGE ROUGH -IN SCHEDULES
<br />II
<br />:OL'DEVICE)
<br />ED2
<br />BASEMENT
<br />AUDITORIUM DEMOLITION
<br />LIGHTING PLAN
<br />.
<br />(AC = ABOVE COUNTER DEVICE)
<br />ED3.01
<br />AUDITORIUM BASEMENT POWERDEMOLITIONPLAN
<br />SURFACE
<br />P = WALL -MOUNTED At DATA DEVICE)
<br />I
<br />I I DEMOLITION
<br />ABOVE CEILING TELECOMMUNICATIONS DEVICE
<br />ED6.01
<br />AUIDITORIUM BASEMENT TELECOM DEMOLITION
<br />'4t�r �.ds...`S s1+5- ;Sn,.„�,ti.�'d.,.. •Ari'. ;,.J{`dT`44Ex y. 3.}$�^ '=ice 3"....
<br />I�
<br />I mil!I
<br />� ; BASEMENT � I
<br />AUDITORIUM PLAN
<br />•iTi W Y,vx.k h"t d t X 'hyyr... .� _i. f i 5 :fti 'f S'S" j`
<br />I
<br />= WIRELESS ACCESS DEVICE)
<br />I(WAP I
<br />AUDITORIUM
<br />VIDEO CAMERA)
<br />DO I B PLAN
<br />.n a
<br />��
<br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD
<br />E&01
<br />y
<br />I
<br />i BASEMENT
<br />UM
<br />aS
<br />+�
<br />` I DETAILS
<br />TELECOM
<br />iOILOW-VOLTAGE ENLARGED PLANS
<br />11-d 10 Q"ice`
<br />rzF{' S^ }.�'a'` �^ s�.s. .}^`ii,�S, y�' �.. ? C�,.A
<br />�i
<br />.,a RACK {
<br />TWO -POST EQUIPMENT
<br />� ,
<br />TELECOMI I LTAGENLARGED D DETAILS
<br />Ck
<br />8.
<br />II
<br />D PLANS ANDDETAILS
<br />■
<br />DOUBLE -SIDED VERTICAL MANAGEMENT
<br />E901
<br />; ONE -LINE DIAGRAMS
<br />ELECTRICAL AND
<br />DOUBLE-SIDED MANAGEMENT
<br />I f
<br />.I
<br />II
<br />t
<br />I
<br />I
<br />FLOOR 7 I I is
<br />MOUNTED
<br />WALL-MOUNTEDENCLOSURE
<br />110 BLOCK WITH LEGS
<br />66 BLOCK
<br />i
<br />Y I- �%ih".I
<br />ACP ACCESS CONTROL PANEL
<br />CREDENTIAL/CARD READER
<br />(CR = CARD READER, WALL -MOUNTED)
<br />C (CR/P = CARD READER W/PIN, WALL -MOUNTED)
<br />(CR/M = CARD READER, MULLION -MOUNTED)
<br />7 DOOR POSITION SWITCH
<br />El DOOR ENTRY STATION, WALL -MOUNTED
<br />2S1 DOOR MASTER STATION, DESK TOP
<br />SECURITY BUTTONS/SWITCH, WALL -MOUNTED
<br />S (AO = AUTO OPERATOR)
<br />XX (DR = DOOR RELEASE)
<br />(LD = LOCKDOWN)
<br />(KS = KEYED SWITCH)
<br />(PB = PANIC/DURESS)
<br />SECURITY BUTTONS, UNDER DESK MOUNTED
<br />(DR = DOOR RELEASE)
<br />XX(LD = LOCKDOWN)
<br />(PS = PANIC/DURESS)
<br />R REQUEST TO EXIT DETECTOR, WALL -MOUNTED
<br />R REQUEST TO EXIT DETECTOR, CEILING -MOUNTED
<br />REQUEST TO EXIT, INTEGRAL MICRO SWITCH
<br />-® REQUEST TO EXIT BUTTON, WALL -MOUNTED
<br />S HORN, WALL -MOUNTED
<br />a A,
<br />STROBE, WALL -MOUNTED
<br />®9s v STROBE/HORN, CEILING -MOUNTED
<br />B
<br />PS DOOR HARDWARE POWER SUPPLY (DIV 08)
<br />X (X = QUANTITY OF DOORS)
<br />EL DOOR HARDWARE POWER SUPPLY (DIV 08)
<br />(EL = ELECTRIFIED LOCKSET/EXIT DEVICE)
<br />(ES = ELECTRIFIED STRIKE)
<br />(ML = ELECTRIFIED MAGNETIC LOCK)
<br />(MH = ELECTRIFIED MAGNETIC HOLD OPEN)
<br />" "� aR I...' ;♦,I;` +�' ti... I {._ ` t I �a .i > ¢ ; ` Iz El
<br />IDP INTRUSION DETECTION PANEL
<br />KEYPAD, WALL -MOUNTED
<br />K
<br />S PIR MOTION DETECTOR, WALL -MOUNTED
<br />S 360 DEGREE PIR/MOTION DETECTOR, CEILING -MOUNTED
<br />P PHOTO -BEAM DETECTOR, WALL -MOUNTED
<br />S DOOR POSITION SWITCH
<br />T TEMPERATURE PROBE
<br />G GLASS BREAK DETECTOR, CEILING -MOUNTED
<br />A AUDIO SENSOR, WALL -MOUNTED
<br />Bs RESCUE ASSISTANCE BASE STATION, WALL -MOUNTED
<br />RA CS RESCUE ASSISTANCE CALL STATION, WALL -MOUNTED
<br />NOT ALL SYMBOLS MAY APPEAR ON THE DRAWINGS
<br />iBi
<br />IA
<br />1
<br />Is
<br />3/27/2019 1:29:18 PM
<br />
|