Laserfiche WebLink
I <br />►I <br />3 1 4 1 5 <br />■ <br />A <br />[in <br />11111111 <br />[a <br />19 <br />15. LOCATIONS OF RACEWAY, PATHWAY AND SIMILAR ITEMS ARE <br />SHOWN SCHEMATICALLY. COORDINATE INSTALLATION, <br />INCLUDING BUT NOT LIMITED TO CABLING, <br />TELECOMMUNICATION PATHWAYS AND SPACES, AND EXACT <br />LOCATION OF HORIZONTAL AND BACKBONE CABLING WITH <br />LOCATIONS OF FIXED CASEWORK AND BUILDING CONDITIONS <br />AFFECTING THE WORK OF THIS CONTRACT. <br />I& COORDINATE TELECOMMUNICATIONS WORK WITH THAT OF <br />OTHER TRADES. REFER TO ELECTRICAL, MECHANICAL, <br />ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE <br />DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL <br />OCCUR PRIOR TO FABRICATION, PURCHASE, AND <br />INSTALLATION OF WORK. <br />17. NEW CABLING INSTALLATIONS SHALL BE CONCEALED IN <br />WALL, CEILINGS, AND BELOW RAISED FLOOR SPACES <br />UNLESS OTHERWISE NOTED ON THE DRAWINGS. CABLING IN <br />ACCESSIBLE CEILING SPACES SHALL BE INSTALLED AS OPEN <br />CABLING NEAR STRUCTURES AND WALLS OR AS <br />SPECIFICALLY NOTED ON DRAWINGS. SEE SPECIFICATIONS <br />FOR SUPPORT REQUIREMENTS. <br />18. PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT AND <br />RACEWAY SYSTEMS AT PENETRATIONS, SLEEVES AND <br />SLOTS OF FIRE RATED CONSTRUCTION FOR HORIZONTAL <br />AND INTRABUILDING PATHWAYS AND SPACES. <br />19. INTRABUILDING OPTICAL FIBER CABLING SHALL BE CLEARLY <br />AND VISIBLY IDENTIFIED IN PULLBOXES, ENTRANCE POINTS, <br />EACH RISER ROOM, AND 5°-0" BEFORE ENTERING A FREE <br />STANDING RACK UTILIZING AN OPTICAL FIBER CABLE MARKER <br />TAG SYSTEM. <br />20. MAINTAIN A MINIMUM SPACING OF 12" FROM ELECTRICAL <br />FEEDERS AND BRANCH CIRCUIT WIRING AND 12" FROM <br />AUXILIARY SYSTEM CABLING. <br />21. MINIMUM SPACING FROM ELECTRICAL APPARATUS SUCH AS <br />MOTOR DRIVEN EQUIPMENT AND TRANSFORMERS SHALL BE <br />6°-0". SPACING REQUIREMENTS SHALL APPLY TO OPEN <br />CABLING PATHWAYS WHERE EQUIPMENT IS LOCATED ON <br />THE SAME FLOOR, FLOOR ABOVE, FLOOR BELOW, OR IN <br />ROOMS ADJACENT TO SUCH EQUIPMENT AS THOUGH WALLS <br />AND FLOORS DID NOT EXIST. EXCEPTION: BUILDING <br />CONSTRUCTION THAT RESULTS IN CONTINUOUS METALLIC <br />BARRIER BETWEEN ELECTRICAL APPARATUS AND CABLE <br />PATHWAYS SHALL BE CONSIDERED AS SUITABLE <br />SEPARATION. <br />22. PRIOR TO STARTING TELECOMMUNICATIONS INSTALLATION, <br />CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES <br />AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT <br />WHERE WORK MAY PROPERLY COMMENCE. NOTIFY THE <br />ARCHITECT AND ENGINEER IN WRITING OF CONDITIONS <br />DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF <br />THE WORK. <br />23. DO NOT BEGIN TELECOMMUNICATIONS INSTALLATION UNTIL <br />ALL UNSATISFACTORY CONDITIONS ARE RESOLVED. <br />BEGINNING WORK CONSTITUTES ACCEPTANCE OF <br />CONDITIONS AS SATISFACTORY. <br />24. ROUTE CATEGORY 5/6A CABLES TO THEIR ASSIGNED CROSS - <br />CONNECT PER THE IDENTIFICATION LABEL AT EACH <br />TELECOMMUNICATIONS WORKSTATION DEVICE. TERMINATE <br />ALL CABLES ON 48-PORT PATCH PANELS ON RACKS UNLESS <br />OTHERWISE NOTED. <br />25. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL <br />CONDUIT, OUTLET BOXES, JUNCTION BOXES, RACEWAY <br />SYSTEMS, ETC. FOR A COMPLETE AND OPERATIONAL <br />PATHWAY SYSTEM FOR ALL TELECOMMUNICATIONS <br />SYSTEMS PER THE SCOPE OF WORK INDICATED ON THE <br />CONSTRUCTION DRAWINGS AND BID SPECIFICATIONS. <br />26. CABLE TRAY PATHWAYS ABOVE ACCESSIBLE CEILINGS SHALL <br />BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CABLE <br />TRAY PATHWAYS BELOW RAISED FLOOR SPACES SHALL BE <br />PROVIDED BY THE TELECOMMUNICATIONS CONTRACTOR. <br />A AMPERE <br />AC AIR CONDITIONING; ALTERNATING CURRENT, <br />ABOVE COUNTER <br />AF AMP FRAME <br />AF AMP FUSE; AMP FRAME <br />AFC AVAILABLE FAULT CURRENT <br />AFF ABOVE FINISHED FLOOR <br />AG ABOVE GRADE <br />AHJ AUTHORITIES HAVING JURISDICTION <br />AHU AIR HANDLING UNIT <br />AIC AMPERE INTERRUPTING CAPACITY <br />AL ALUMINUM <br />ANSI AMERICAN NATIONAL STANDARDS INSTITUTE <br />AS AMP SWITCH <br />AT AMP TRIP <br />ATM AUTOMATIC TRANSFER SWITCH <br />ATS ASYNCHRONOUS TRANSFER MODE <br />AV AUDIO VISUAL <br />AWG AMERICAN WIRE GAUGE <br />BAS BUILDING AUTOMATION SYSTEM <br />BATT BATTERIES <br />BIL BACKBOARD <br />BKBD BASIC IMPULSE INSULATION LEVEL <br />BKR BREAKER <br />BLDG BUILDING <br />C CONDUIT; DEGREES CELCIUS <br />CAB CABINET <br />CAT CATEGORY <br />CATV COMMUNITY ANTENNA TELEVISION <br />CB CIRCUIT BREAKER <br />CCTV CLOSED CIRCUIT TELEVISION <br />CLG CEILING <br />CM CEILING —MOUNTED <br />CO CONDUIT ONLY <br />CR CONTROLLED RECEPTACLE <br />CT CURRENTTRANSFORMER <br />CU COPPER <br />D DEDICATED <br />DDC DIRECT DIGITAL CONTROL <br />DEMARC DEMARCATION POINT <br />DISC DISCONNECT <br />DIST DISTRIBUTION <br />DSL DIGITAL SUBSCRIBER LINE <br />DWG DRAWING <br />(E) EXISTING <br />EA EACH <br />EF EXHAUSTFAN <br />EIA ELECTRONIC INDUSTRIES ASSOCIATION <br />ELEV ELEVATION <br />EM EMERGENCY <br />EMT ELECTRICAL METALLIC TUBING <br />ENCL ENCLOSURE <br />EPM ELECTRONIC POWER METER <br />EPO EMERGENCY POWER OFF <br />EQUIP EQUIPMENT <br />ETR EXISTING TO REMAIN <br />EWC ELECTRIC WATER COOLER <br />F FUSES; DEGREES FAHRENHEIT <br />FA FIRE ALARM <br />FAAP FIRE ALARM ANNUNCIATOR PANEL <br />FACP FIRE ALARM CONTROL PANEL <br />FBO FURNISHED BY OWNER <br />FOIC FURNISHED BY OWNER INSTALLED BY <br />CONTRACTOR <br />FOIO FURNISHED BY OWNER INSTALLED BY OWNER <br />FSD FIRE SMOKE DAMPER <br />G GROUND <br />GF GROUND FAULT CIRCUIT INTERRUPTER <br />GFP GROUND FAULT PROTECTION <br />GND GROUND <br />GRS GALVANIZED RIGID STEEL <br />HC HORIZONTAL CROSS CONNECT <br />HID HIGH INTENSITY DISCHARGE <br />HP HORSEPOWER <br />HTR HEATER <br />Hz HERTZ <br />IBC INTERMEDIATE CROSS CONNECT <br />IC INTERNATIONAL BUILDING CODE <br />IDF INTERMEDIATE DISTRIBUTION FRAME <br />IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC <br />ENGINEERS <br />IG ISOLATED GROUND <br />IMC INTERMEDIATE METALLIC CONDUIT <br />ISDN INTEGRATED SERVICES DIGITAL NETWORK <br />J JUNCTION <br />KCMIL THOUSAND CIRCULAR MILS <br />kVA KILOVOLT AMPERE <br />KVAR KILOVOLT AMPERE REACTIVE <br />kW KILOWATT <br />LAN LOCAL AREA NETWORK <br />LCP LIGHTING CONTROL PANEL <br />LEC LOCAL EXCHANGE CARRIER <br />LT LIGHT <br />LTG LIGHTING <br />M METER <br />MAN METROPOLITAN AREA NETWORK <br />MAX MAXIMUM <br />MC MAIN CROSS CONNECT; METAL CLAD (CABLE) <br />MCB MOTOR CONTROL CENTER <br />MCC MAIN CIRCUIT BREAKER <br />MDF MAIN DISTRIBUTION FRAME <br />MDP MAIN DISTRIBUTION PANEL <br />MFR MANUFACTURER <br />MH MANHOLE <br />MIN MINIMUM <br />MLO MAIN LUGS ONLY <br />MM MULTIMODE <br />MPOE MAIN POINT OF ENTRY <br />MPOP MAIN POINT OF PRESENCE <br />MTD MOUNTED <br />MTS MANUAL TRANSFER SWITCH <br />(N) NEW <br />N NEUTRAL <br />NAC NOTIFICATION APPLIANCE CIRCUIT <br />NEC NATIONAL ELECTRICAL CODE <br />NEMA NATIONAL ELECTRICAL MANUFACTURERS <br />ASSOCIATION <br />NF NON —FUSED <br />NIC NOT IN CONTRACT <br />NL NIGHT LIGHT <br />OFC OPTICAL FIBER CABLE <br />OHL OVERHEAD LINE <br />OL OVERLOAD <br />OS OCCUPANCY SENSOR <br />OSP OUTSIDE PLANT <br />P POLE <br />PBX PRIVATE BRANCH EXCHANGE <br />PF POWER FACTOR <br />PH PHASE <br />PIR PASSIVE INFRARED <br />PIV POST INDICATING VALVE <br />PNL PANEL <br />PP PATCH <br />PT POTENTIAL TRANSFORMER <br />PVC POLYVINYL CHLORIDE <br />RCP REFLECTED CEILING PLAN <br />REC RECEPTACLE <br />REF REFER TO <br />REV REVISION <br />RM ROOM <br />RTRC REINFORCED THERMOSETTING RESIN CONDUIT <br />RU RACK UNIT <br />SHT SHEET <br />SLC SIGNALING LINE CIRCUIT <br />SM SINGLEMODE <br />SMFC SURFACE —MOUNTED OPTICAL FIBER CABINET <br />SMR SURFACE METAL RACEWAY <br />SONET SYNCHRONOUS OPTICAL NETWORK <br />SP SERVICE PROVIDER <br />SPD SURGE PROTECTIVE DEVICE <br />SPEC SPECIFICATIONS <br />SPST SINGLE POLE SINGLE THROW <br />ST SHUNT TRIP <br />STP SHIELDED TWISTED PAIR <br />SVGA SUPER VIDEO GRAPHICS ARRAY <br />SW SWITCH <br />SWBD SWITCHBOARD <br />TBB TELECOMMUNICATIONS BONDING BACKBONE <br />TEL TELEPHONE <br />TELCO TELEPHONE COMPANY <br />TGB TELECOMMUNICATIONS GROUNDING BUSBAR <br />TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION <br />TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR <br />TP TAMPERPROOF <br />TR TELECOMMUNICATIONS ROOM <br />TTB TELEPHONE TERMINAL BOARD <br />TV TELEVISION <br />TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION <br />TYP TYPICAL <br />UG UNDERGROUND <br />UL UNDERWRITERS LABORATORIES <br />UON UNLESS OTHERWISE NOTED <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />USB UNIVERSAL SERIAL BUS <br />UTP UNSHIELDED TWISTED PAIR <br />UV UNIT VENTILATOR <br />V VOLTS <br />VA VOLT AMPERES <br />VFD VARIABLE FREQUENCY DRIVE <br />W WASTE, WATT, WIDE, WATER <br />W/ WITH <br />W/O WITHOUT <br />WA WORKSTATION AREA <br />WAN WIDE AREA NETWORK <br />WG WIRE GUARD <br />WH WATT HOUR METER <br />WP WEATHERPROOF <br />XMFR TRANSFORMER <br />Y WYE <br />Z IMPEDANCE <br />.�MOM— "IM410 I.aal"tul„.1 , � I <br />1. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE <br />2015 INTERNATIONAL BUILDING CODE AND FROM THE <br />AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD <br />7. THE CONTRACTOR SHALL REFER TO THE ABOVE FOR <br />ADDITIONAL INFORMATION, EXCEPTIONS, AND FURTHER <br />DESCRIPTIONS. THE CONTRACTOR SHALL ADHERE TO <br />REQUIREMENTS AND AS SUCH, SHALL BE INCLUDED WITHIN <br />BID. ALSO REFER TO SPECIFICATIONS. <br />2. 2015 IBC 1613.1 SCOPE: ARCHITECTURAL, <br />C URAL MECHANICAL <br />, <br />ELECTRICAL AND NON-STRU <br />CTURAL COMPONENTS THAT <br />ARE PERMANENTLY ATTACHED TO STRUCTURES AND THEIR <br />SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AND <br />CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE <br />MOTIONS IN ACCORDANCE WITH ASCE 7, EXCLUDING <br />CHAPTER 14 AND APPENDIX 11A. <br />3. ASCE 7 CONTRACTOR RESPONSIBILITY: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />CONSTRUCTION OF A SEISMIC -FORCE -RESISTING SYSTEM, <br />DESIGNATED SEISMIC SYSTEM, OR COMPONENT LISTED IN <br />THE QUALITY ASSURANCE PLAN SHALL SUBMIT A WRITTEN <br />CONTRACTOR'S STATEMENT OF RESPONSIBILITY TO THE <br />AUTHORITY HAVING JURISDICTION AND TO THE OWNER <br />PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM <br />OR COMPONENT. THE CONTRACTOR'S STATEMENT OF <br />RESPONSIBILITY SHALL INCLUDE THE FOLLOWING: <br />A. ACKNOWLEDGMENT OF AWARENESS OF THE <br />SPECIAL REQUIREMENTS CONTAINED IN THE <br />QUALITY ASSURANCE PLAN; <br />B. ACKNOWLEDGMENT THAT CONTROL WILL BE <br />EXERCISED TO OBTAIN CONFORMANCE WITH <br />THE CONSTRUCTION DOCUMENTS APPROVED BY <br />THE AUTHORITY HAVING JURISDICTION; <br />C. PROCEDURES FOR EXERCISING CONTROL <br />WITHIN THE CONTRACTOR'S ORGANIZATION, <br />THE METHOD AND FREQUENCY OF <br />REPORTING AND THE DISTRIBUTION OF THE <br />REPORTS, AND <br />D. IDENTIFICATION AND QUALIFICATIONS OF THE <br />PERSON(S) EXERCISING SUCH CONTROL AND <br />THEIR POSITION(S) IN THE ORGANIZATION. <br />4. DIVISION 26 RESPONSIBILITIES: <br />A. HANGERS, AND SEISMIC BRACING FOR <br />ELECTRICAL SYSTEMS SHALL BE DESIGNED <br />AND SPECIFIED BY DIVISION 26. DIVISION 26 <br />SHALL REFER TO THE ELECTRICAL <br />DRAWINGS FOR LOCATIONS OF EQUIPMENT <br />AND ELECTRICAL SYSTEMS AS STRUCTURAL <br />DRAWINGS DO NOT SHOW THE LOCATIONS OF <br />ELECTRICAL EQUIPMENT, RACEWAYS, AND <br />OTHER COMPONENTS. <br />B. DIVISION 26 SHALL COORDINATE THE <br />SUPPORT SYSTEMS AND DESIGN LOADS FOR <br />HUNG RACEWAYS AND OTHER ELECTRICAL <br />SYSTEMS (INCLUDING COMBINED MULTIPLE <br />RACEWAY RUNS) WITH THE GENERAL <br />CONTRACTOR AND THE STEEL AND WOOD <br />JOIST MANUFACTURERS IN ADDITION TO <br />OTHER TRADES THAT MAY BE IMPACTED. <br />ENERGY E NOTES <br />RECORDDRAWINGS: SUBMIT O THE <br />OWNER PER <br />ENERGYCODE ENFORCED BY � <br />MANUALS:2. OPERATION AND MAINTENANCE <br />E BUILDING OWNER PER ENERGY CODE ENFORCED <br />B� <br />Y THE LOCAL AHJ. <br />3. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN <br />DESIGNED O COMPLY WITH ENERGYOIII <br />ENFORCED BY THE LOCALAHJ. CONTRACTIS <br />OR <br />RESPONSIBLE <br />i!. -O- E. -CORRECT INSTALLATION OF <br />ENERGY CONSERVATION MEASURES. <br />t i. <br />COMPLETION4. LIGHTING CONTROL SYSTEMS COMMISSIONING AND <br />REQUIREMENTS: TEST SYSTEMS TO <br />ENSURE THAT BUILDING SYSTEMS HAVE <br />INSTALLED AND FUNCTIONPROPERLY D <br />EFFICIENTLY, AND CAN BE MAINTAINED <br />ACCORDANCE•' <br />OPERATIONAL ENERGY <br />ENFORCED BY THE AHJ. REFER TO SPECIFICATIONS <br />FOR ADDITIONAL O • <br />I <br />"mg <br />IBM <br />.r� «k>u ..,:.. s..1 d,....°5-- <br />k' "'��r'S;':-e!�.�.4.x:k .'n�:.� <br />(Hargis Engineers, Inc. <br />1201 Third Avenue, Suite 600 <br />Seattle, WA 98101 <br />" <br />F <br />ABBREVIATIONS AND <br />GENERAL <br />i 4 4 � )$ NOTES <br />d ,4 4 <br />I <br />K <br />3 1 4 <br />Q <br />I <br />is I'm <br />