Laserfiche WebLink
STAGGER SIDING <br />BUTT JOINTS AT MIN. 32" <br />CENTERED ON STUDS TYP. <br />PER IBC 1405.16 - <br />3 FIBER CEMENT LAP SID'G <br />TO HAVE MIN. 1 1/4" <br />3 F WEATHER BOARD LAP <br />1/2" PLYWD SHEATH'G <br />OR 7/16" OSB SHEATH'G <br />15# FELT VB <br />w <br />i MFG. JOINT FLASH'G <br />AT EACH JOINT IN <br />SIDING PER MFG. REQ. <br />MIN. 1/4" THICK FIBER CEMENT LAP SIDING <br />NOTE - <br />BLIND NAILING AT JOINTS AT 3/8" TO 1/2" FROM ENDS <br />1/4" OF BOARDS. USE FACTORY CUT ENDS OF BOARDS <br />AT BUTT JOINTS. PAINT OR PRIME ALL FIELD CUT SURFACES <br />S <br />ID�ING JOINTS — FIBERT <br />GA D3/4-on SI IOPTION) <br />WEATHER LAP SIDING 1 1/4" <br />(CEDAR OR CEMENT BOARD <br />SIDING) OVER15# FELT <br />STARTER COURSE APPLIED <br />TO MAINTAIN A 1/2" DRIP <br />PROVIDE WEEP GAP OF <br />1/2" AT MIN. 48" O.C. <br />WRAP GAP AREA W/ INSECT <br />SCREEN <br />V_' <br />CONC. STEM WALL <br />GRADE <br />3/4" ® 18—Q9' RE , SEPARATION FROM EARTH <br />PROVIDE LIBERAL SEALANT <br />AT PENETRATION THRU <br />SHEATHING - HEAT RESISTANT <br />AS REQUIRED. <br />PROVIDE LIBERAL SEALANT <br />AT TOP AND SIDES OF BLK <br />TYP. LAP SIDING <br />_ PROVIDE STARTER <br />LAP FELT OVER T FLASH'G <br />STRIP AT CUT FOR <br />PROVIDE STARTER STRIP AT <br />TRIM BLOCK AS <br />SIDING HOLDING SIDING 1/4" <br />_ REQUIRED. <br />ABOVE T FLASH'G <br />�15# FELT - LAP <br />OVER T FLASHING <br />TFLASHING FULL WIDTH OF <br />TRIM BLOCK W/ 1" DRIP <br />- Z' FLASHING - <br />EXTEND 2" UP <br />SEALANT OVER BACKER ROD <br />SHEATHING <br />BTWN TRIM BLOCK AND <br />OVER TRIM BLOCK <br />PENETRATION <br />' SOLID TRIM BLOCK <br />EXHAUST WEATHER CAP OR <br />I <br />(MIN. -CUT <br />OTHER PENETRATION LARGER <br />INTO TWO O PIECES <br />W <br />THAN 1 1 2"� <br />/ <br />AS REQUIRED W/ <br />2x TRIM BLOCK AT VENT <br />WEATHER CUT OF <br />PENETRATION <br />MIN, 22.5' <br />CONTINUOUS SEALANT BTWN <br />TRIM BLOCK AND SIDING AT <br />NOTE - SEAL BTWN TRIM BLOCK AND PENETRATION <br />SIDES AND BOTTOM OF BLOCK <br />WITH BACKER ROD AND SEALANT - USE OF HEAT <br />RESISTANT ROD AND SEALANT AS REQUIRED. <br />3/4" ® 1,0 n <br />EXTEND TRIM TITLE AROUND <br />WINDOW - TILE HD, JAMB <br />AND SILL <br />AWN / <br />B GL , <br />PROVIDE BLK'G FOR FUTURE <br />GRAB BARS TYP. <br />MRGWB TYP. <br />PAINT W/ PVA PRIMER, 2 C <br />OF GLOSS AT TILED AREA <br />l <br />1 1/2° <br />CAP <br />:o <br />61, <br />MAX <br />SEAT <br />______ <br />2 1/2" 1 <br />MAX. <br />SHOWER — SOUTH SHOWER ENCLOSURE —WEST <br />BATH /SHOWER ELEVmllATIONS <br />HOUSE WRAP <br />TAPE AT HD <br />All J4MB V <br />in <br />=: 1-o <br />" <br />DIAG; 1 x T&G FLOOR <br />OVER 2x6 FL JOISTS <br />MRGWB TYP. <br />PAINT W/ PVA PRIMER, 2 COASTS <br />OF GLOSS AT TILED AREA <br />SHAMPOO RECESS <br />_ 15" <br />MAX <br />PROVIDE BLK'G FOR FUTURE <br />GRAB BARS AND FOLD'G BENCH TYP. <br />SHOWER / BATH — WEST <br />\v <br />EXISTING 1xB SHIP LAP OVER 2x6 <br />I <br />I <br />RIM JOIST AND PT 20 MID SILL <br />EXISTING 1/2"0 ANCHOR BOLT <br />INTO GROUTED CELL <br />NEW ROOF TRUSSES TYP, <br />EXISTING BATT INSUL. <br />AT 24" O.C, <br />® <br />EXISTING 6" CMU FOUNDATION <br />EACH TRUSS TO EXISTING PLATE INSTALL <br />EXISTING CRAWL SPACE ,,- <br />N <br />WALL <br />(2) SDWC15600 TO EACH WALL PLATE <br />EXISTING VISQUEEN VB� OfEXISTING <br />GRADE <br />INSTALL PER SDWC DETAIL <br />1,115 lb. UP / 920 lb, THRUST / 645 lb, LATERAL <br />(EACH PR TRUSS SCREWS) <br />olm-low —mill so =---" <br />3/4' = 1 p® " <br />MRGWB TYP. <br />PAINT W/ PVA PRIMER, 2 COASTS <br />OF SEMI -GLOSS AT BATH RM <br />40" <br />PROVIDE BLK'G FOR FUTURE <br />GRAB BARS TYP. <br />MRGWB TYP. <br />PAINT W/ PVA PRIMER, 2 COASTS <br />OF SEMI -GLOSS <br />CWD <br />r <br />OCKET DR <br />18" <br />24" <br />.TP DSP. <br />_ <br />ADA <br />APPROVED <br />TOILET <br />BATH — NORTH <br />MIN. 1/2" COX PLYWD ROOF SHEATH'G <br />W/ 8d AT 6" O.C. PANEL EDGES <br />AND 8d AT 12" O.C. PANEL FIELD, <br />MIN. 1/2" CDX PLYWD ROOF <br />SHEATHING W/ 8d AT 6° O.C.. PANEL EDGES 2 1Od END <br />AND 8d AT 12" O.C. PANEL FIELD NAIL TO EA. <br />OUTLOOKER <br />8d AT 6" O.C. ROOF SHEATH'G TO <br />CONT. BLK'G AND TRUSSES - ----- -- -- ---- <br />2x8 VENTED BLK'G BTWN TRUSSES 17- - - - - <br />TYP. <br />3 16d BLK'G TO TOP PLATE BRACING PER <br />() TRUSS MFGR. <br />EACH TRUSS TO EXISTING PLATE INSTALL <br />IN <br />DBL 2x4 PER WALL FRAMING OR <br />HGA1O W/ 1/4" x 2 1/2" SOS SCREWS <br />DBL 2x4 PLATE TOP WALL <br />AT 48" O.C. TYP. <br />605 lb. UP / 720 lb. THRUST / 500 lb, LATERAL <br />EXISTING BEARING WALL- <br />2x4 STUDS AT 16" O,C. WITH <br />1 x 8 (7/8"x 7 1/2") SHIP LAP <br />W/ MIN. (2) 10d TO EA. STUD <br />OVER 2x4 STUDS AT 16" O.C. <br />(NOT ALIGNED SPACING) W/ <br />1 x8 SHIP LAP TO INSIDE FACE <br />OF WALL <br />TRUSS COINN AT EXIST G BRG WALL, <br />3/4" = 1'_on - <br />LAY HOUSE WRAP DOWN OVER HEAD 11 MATCH THE WIDTH OF THE HD FLASHING <br />AT 45° TO FLASHING AND TAPE THE 45° CUTS 'INSTALL METAL T FLASH <br />LIFT FLAP OF HOUSE CUT HOUSE WRAP <br />WRAP TO INSTALL MATCH HEIGHT AP HEAD IN THE HOUSE WRAP TO THE FLASHING AT WINDOW HEAD TO MATCH <br />OF <br />DO IN T TION (IN R E - OVER HEAD FLASHING FLASHING W/ COMPATIBLE TAPE. D 9 SET IN BEADS OF MIN. <br />SEALANT -SEE DETAIL i <br />HOUSE WRAP OVER EXTERIOR FACE (D HEAD FLASHING ACROSS THE HEAD ---- -__ -----------------------------------------------------------__-_----___ Q <br />OF SHEATHING THAT IS TO RECEIVE OF THE WINDOW UNIT TO A MIN. DISTANCE - r'- - ------ -- r--------- <br />- ---------------------- ------------------ <br />WINDOWS, DOORS, SIDING, TRIM OR OF THE WIDTH OF FLASHING + 1" <br />HOUSE WRAP (15 FELT) HEAD FLASHING - EXTEND PAST R.O. <br />ER <br />ANY OTHER FORM OF EXTERIOR CLADDING LAY HOUSE WRAP DOWN OVER ! i OER WALgTHER ASHEATHING, ;�. EACH SIDE <br />THE FLASHING WIDTH �1' <br />2� CUT HOUSE WRAP AT ALL ROUGH HEAD FLASHING 12 6 <br />OPENINGS AND WRAP AROUND AROUND Q TAPE 46 CUTS IN HOUSE WRAP i T LINE OF I <br />1 �B FLASHING -EXTEND F,91N. FLASHING <br />TO INTERIOR FACE OF ROUGH OPENING, WITH TAPE COMPATIBLE FIT HOUSE I ; ; ; HOUSE WRAP � ; � � I ; WIDTH PAST HEAD OF R.O. AND MIN, <br />INFILL WRAP MATERIAL AT CORNERS WRAP j ; OR FELT ! ! �✓ OF ROUGH OPENINGS TO BE WRAPPEDSTUDS BEYOND 1" PAST SILL FLASHING. DIAG, 1x TAG FLOOR <br />APPLY 3/8" BEAD OF SEALANT AT I TO INSIDE OF ! ! 10 C INSTALL WINDOW UNIT OVER SHEATHING OVER 2x6 FL JOISTS <br />'D CUT HOUSE WRAP AT HEAD OF R.O. THE JOINT BETWEEN THE WINDOW UNIT j FRAMED R.O. i APPLY SEALANT BETWEEN :2-1 IN R.O. - SET IN SEALANT PER NOTES <br />AT 4� TO A DISTANCE REQUIRED TO AND FLASHING OR HOUSE WRAP. i <br />I� II II tI �� WINDOW UNIT AND SECURE TO WALL PER MFGR REQUIREMENTS <br />MATCH THE WIDTH OF THE HEAD FLASFI G 1 I; I I III I I I I <br />11 RIGID METAL TFLASHING INSTALLED ! 1 I HD JAMB SILL FLASHING <br />" ACROSS LENGTH OF THE NERD ! PER WINDOW MFG. TYP. EXISTING ]x8 SHIP LAP OVER 2x6 <br />SEALANT AT THE INSIDEWINDOW UNIT - SET /FACE OF NA1L0G OF THE WINDOW UNIT AND SET IN 3/8" _ RIM JOIST AND PT 2x4 MID SILL <br />Y3 <br />1) ill II II II 11 II <br />FLANGE_ ALONG THE THE LINE OF PRE- BEAD Of SEALANT AT TOP Of Z FLASH - <br />PUNCHED Ai7A,CHMENT HOLES AND Al TOP Of WINDOW UNIT. SECURE ; ; EDGE OF ROUGH OPENING J EXISTING 1 /2 ANCHOR BOLT <br />'Z' FLASH WITH GALVANIZED NAILS OR i INTO GROUTED CELL <br />5 SILL FLASHING OVER HOUSE WRAP l i S <br />1 I <br />Q SCREWS AT MIN. 6" O.C. APPLY SEALANT I I I l I 1 I ; ; 1 I I I ; I , -_-- __-- Q EXISTING BATT INSUL. <br />AND WINDOW SILL NAIL'G FLANGE i ' SILT FLASHING -EXTEND PAST R.O. o <br />11 i1 II ,I I. ;; ROUGH OPENING i <br />OVER FASTENERS. i <br />I II II II 1 TILT II II E� <br />TO A MIN, PAST THE R.O. = WIDTH OF ll i 1 MIN. MIN. EQUAL TO JAMB FLASH'G WIDTH H I EXISTING GRADE <br />12 APPLY SEALANT OVER ALL VERTICAL I " EXISTING CRAWL SPACE ' <br />JAMB FLASHING + 1° i, 1 I I III I I I � I ;; I 11 I 1 1 I 1 + MIN. 1 AT EACH SIDE. <br />JOINTS BETWEEN HEAD JAMB OR SILL <br />INSTALL JAMB FLASHING OVER HOUSE TRIM AND SIDING i 1 % ( `� <br />� 11 II I 11 II II 1, 11 II it <br />1 II Ilil it ii II i'i1 ' � <br />HOUSE WRAP 15 FELT MOISTURE EXISTING VISQUEEN VB <br />WRAP AND WINDOW JAMB FLANGE TO MIN. i 1 1 1 Ill BARRIER) OVER WALL SHEATH'G <br />1" PAST SILL FLASHING AND MIN. EQUAL i EXISTING 6' CMU FOUNDATION <br />------ i l <br />TO WIDTH OF JAMB FLASHING VERTICAL Ill I <br />I II 11 I 11 II 1 WALL <br />PAST R.O. HEAD. <br />HOUSE RAP AT ROUGH PE'G I INSTALLATION WITHFLASH CAL <br />EXIST'G FOUNDATION T TEAND Su"u''TH <br />ENVELOPE PENETRATINDOW)I E 3/4 89 = V®n-- —— -- <br />3/41'®off <br />PLUMBING <br />PL'IND <br />I I <br />VENT AND <br />WALL <br />WATER <br />SUPPLY IN <br />WALL <br />8d AT 6" O.C. ROOF SHEATH'G TO <br />CONT. BLK'G AND OUTLOOK FRAM'G <br />GABLE END TRUSS AT EXISTC WALL <br />3/4" = 19-0y) <br />DIAG. 1x T&G FLOOR <br />OVER 2x6 FL JOISTS <br />EXISTING BATT INSUL! <br />EXISTING PT LEDGER <br />EXISTING CRAWL SPACE <br />EXISTING VISQUEEN VB <br />�I <br />° <br />y � <br />i <br />EXISTING 1x8 SHIP LAP AT <br />EA. FACE OF DBL 20 STUD <br />WALL - <br />TYP. EXIST EXTERIOR WALL <br />EXISTING 1x8 SHIP LAP OVER <br />PT 2x4 MUD SILL W/ 1/2" 0 <br />ANCHOR BOLT IN GROUTED CELL <br />VARIES - 4" TO 12" <br />EXISTING GRADE <br />EXISTING 6" CMU FOUNDATION <br />WALL _ C <br />% r U <br />r�3 <br />D <br />= Q ; � <br />U) o � a- <br />l fy c)F E VERE TT <br />FXIST'G FOUNDATION AT WEST <br />3/4u = i �_to <br />2018 DEC 3 wr17 <br />