GENERAL NOTES <br />CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS <br />PRIOR TO COMMENCING THE WORK, <br />WORK SHALL COMPLY WITH THE FOLLOWING CODES: <br />2015 INTERNATIONAL RESIDENTIAL CODE <br />2015 WASHINGTON ENERGY CODE <br />OTHER CODES APPLICABLE BY JURISDICTION, <br />AIR SEALING: <br />1. ALL PLUMBING, ELECTRICAL, AND HVAC PENETRATIONS IN FLOOR, <br />WALLS, AND CEILINGS ARE CAULKED AND SEALED. <br />2. WHERE PENETRATIONS NEED A FIRESTOP, DISCUSS WITH <br />BUILDING OFFICIAL, <br />3. ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR <br />WALLS MUST BE SEALED AT THE BACK OF THE RECEPTACLE OR <br />SEALED WITH FACEPLATE GASKETS, <br />4. SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT <br />LIKE "TYVEK" ON EXTERIOR, <br />5, VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS, 4 MIL. <br />VISQUEEN OR AN APPROVED VAPOR BARRIER PAINT, <br />SEPARATION BETWEEN DWELLING AND GARAGE/CARPORT; <br />a. NO SEPARATION REQUIRED IF ENTIRELY OPEN ON 2 OR MORE <br />SIDES AND NO ENCLOSED USES, (OPEN DECKS ABOVE ARE OKAY, <br />NON -RATED WALLS AND OPERABLE WINDOWS BETWEEN THE <br />DWELLING AND CARPORT ARE OKAYj. <br />b. MINIMUM 1/2" GWB ON GARAGE/CARPORT SIDE OF WALLS <br />REQUIRED FOR ALL GARAGES/CARPORTS NOT COVERED BY 1A <br />ABOVE. <br />c. 1-HOUR FIRE RATED WALL REQUIRED IF LESS THAN 5 FEET FROM <br />PROPERTY LINE (NO OPENINGS ALLOWED LESS THAN 3' FROM <br />PROPERTY LINE 25% MAXIMUM OPENINGS BETWEEN 3' AND 5' TO <br />PROPERTY LINE). OVERHANGS MUST BE A MINIMUM 2' FROM <br />PROPERTY LINE, EXCEPT STEEL GUTTER ALLOWED CLOSER AND <br />5/8" GWB SHEATHING REQUIRED ON UNDERSIDE WHEN 5' OR LESS <br />FROM PROPERTY LINE, <br />EGRESS WINDOWS: REQUIRED FOR 1 WINDOW/BEDROOM OR SLEEPING <br />AREA (BELOW 4TH FLOORI AND 1 WINDOW/BASEMENT <br />a. MIN, NET CLEAR AREA = 57 SQ. FT,, (MIN, 310" x 416" IF DOUBLE <br />HUNG OR 4'0" x 316" WINDOW IF SLIDER). 5.0 SQ. FT, IF SILL <br />HEIGHT IS WITHIN 44" OF GRADE (ABOVE OR BELOW), <br />b, MIN. NET CLEAR OPENING WIDTH = 2011; MIN. NET CLEAR OPENING <br />HEIGHT = 24" <br />C. MAX, SILL HEIGHT = 44" (ONE PERMANENTLY INSTALLED STEP <br />WITH MAX. 8" RISE AND MIN 9" RUN OKAY FOR EXISTING <br />BEDROOMS), <br />REQUIRED GLAZING FOR HABITABLE ROOMS: <br />a. MIN GLAZED EXTERIOR OPENING AREA = 8X OF FLOOR AREA. <br />b. GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY <br />INSTALLED ARTIFICIAL LIGHT IS PROVIDED. <br />c. OK IF OPENINGS ARE BELOW DECK & ROOFED PORCHES w/MIN. <br />CEILING HEIGHT OF 7 FT. (LONG SIDE 65% OPEN). <br />MECHANICAL/VENTILATION; REQUIRED FOR HABITABLE ROOMS OF <br />ADDITIONS AND ALTERATIONS MORE THAN 500 SQ, FT, OR THAT <br />INCLUDE A KITCHEN, BATHROOM AND OTHER AREA'S WHERE COOKING <br />ODOR OR EXCESS WATER VAPOR WILL BE PRODUCED. <br />a. MIN. 50 CFM FOR BATHROOM AND LAUNDRY; MIN. 100 CFM FOR <br />KITCHEN. <br />b. MIN. AIR INTAKE OPENINGS = 4 SQ. IN. PER ROOM, <br />c, WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN IRC M1507.3 <br />SMOKE ALARMS: REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS <br />AND ON ALL FLOORS, DIRECT WIRING IS REQUIRED FOR SMOKE <br />DETECTORS, UNLESS REMOVAL OF INTERIOR WALL OR CEILING FINISHES <br />IS NECESSARY TO INSTALL THE WIRING <br />CARBON MONOXIDE ALARMS: REQUIRED OUTSIDE SLEEPING AREAS AND <br />ON ALL FLOORS, UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES <br />OF THE BUILDING. <br />STAIR REQUIREMENTS: (APPLIES TO ALL R-3 STAIRS AND R-2 PRIVATE <br />STAIRWAYS): <br />a, MIN. WIDTH = 36" <br />b, MAX, HEIGHT/RISE = 7-3/4"; MIN. TREAD RUN = 10" <br />C. MIN, HEADROOM = 6'8" <br />d. HANDRAIL 34"-38" ABOVE TREAD NOSING (RETURN ENDS) <br />e, HANDRAIL GRASP DIMENSION: MIN, 1-1/411, MAX. 2" <br />f. WINDING STAIRS: <br />1, MIN, TREAD RUN AT NARROWEST POINT = 6" <br />2. MIN, TREAD RUN 1211 FROM NAORROWEST POINT = 10" <br />g, SPIRAL STAIRS: <br />1. MIN. CLEAR WALKING AREA WIDTH = 26" <br />2, MIN, TREAD RUN 12" FROM NARROWEST POINT 7-1/2" / <br />MAX. RISER HEIGHT = 9-1/2" <br />3, MIN. HEADROOM = 6161" <br />CEILING HEIGHT IN ADDITIONS AND ALTERATIONS: <br />a. MIN. 7'0": FOR NEW CONSTRUCTION OR ADDITIONS <br />b. MIN 64": IF BUILDING WAS IN EXISTENCE PRIOR TO 10/17/79 (SEE <br />DR 23-2008 FOR SPECIFICS). <br />C. ROOMS WITH SLOPED CEILINGS REQUIRE MINIMUM CEILING HEIGHT <br />IN 1/2 OF THE AREA, (PORTIONS OF THE ROOM WITH CEILING <br />HEIGHT LESS THAN 5 FT, DO NOT COUNT IN TOTAL AREA). <br />INSULATION: <br />1. FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING <br />MEMBERS, <br />2. ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED <br />INSULATION, INCLUDING ALL CAVITIES ISOLATED DURING FRAMING, <br />WIRING, AND PLUMBING <br />3. ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID BOARD <br />INSULATION BEHIND THEM <br />4. UNDERFLOOR INSULATION IS SUPPORTED BY LATH, TWINE, OR <br />OTHER NON -COMPRESSING MEANS, <br />5, ATTIC ACCESS IS BAFFLED, WEATHER-STRIPPED AND INSULATED. <br />FOUNDATION LOCATION, PROPERTY CORNERS MUST BE ACCURATELY <br />DETERMINED AND INDICATED0 FOR FOUNDATION INSPECTION. A <br />N SITE <br />SURVEY MAY BE REQUIRED. FENCE LOCATIONS WILL NOT BE ACCEPTED <br />AS ESTABLISHING PROPERTY CORNERS, <br />OTHER REQUIREMENTS: <br />a. GUARDRAILS: MIN, 36" HT, MAX, 4" SPACING BETWEEN <br />INTERMEDIATE MEMBERS 142" MIN. HT FOR R-2 EXTERIOR). <br />b. FOORINGS: BOTTOM MIN. 12" BELOW GRADE, TOP OF FOUNDATION <br />WALL MIN, 6" ABOVE GRADE <br />c: CONRETE SLABS ON GRADE; 3-1/2" MIN. THICKNESSES, <br />d. PIER BLOCKS; MIN. 12" X 12" SIZE; RESTING ON CONCRETE PAD <br />MIN. 12" BELOW GRADE. <br />e. FOUNDATION WALLS. PROVIDE ONE 01 #4 REBAR TOP AND BOTTOM <br />AND AT ALL WINDOWS/DOOR OPENINGS, LIMIT 4' MAX. BACKFILL. <br />f. FOUNDATION ANCHOR BOLTS, MIN. 1/2" x 10,11 6 FT, ON CENTER <br />MAX. WITH TWO (2) BOLTS PER PIECE OF PLATE AND AT LEAST <br />ONE 11) BOLT WITH 12" AT END OF EACH PIECE REQUIRED FOR <br />NEW CONSTRUCTION). <br />g, ALL STRUCTURAL SOFTWOOD PLYWOOD, PARTICLE BOARD, WAFER <br />BOARD, AND OSB BOARD ARE STAMPLED WITH EXPOSURE '1' OR <br />'EXTERIOR', <br />h. WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L <br />APPLIANCE ENERGY CONSERVATION ACT. ASHRAE STANDARD <br />9OA-1980 INSULATION TO R-16 OR R-10 PAD IF LOCATED OVER <br />UNINSULATED SLAB, <br />i. INSULATE HOT AND COLD WATER PIPES TO R-3 IN UNHEATED <br />AREAS. <br />j, SHOWER REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2.5 <br />GPM <br />k. WOODSTOVES AND FIREPLACES HAVE TIGHT FITING DOORS, <br />OUTSIDE COMBUSTION AIR DUCTED TO FIREBOX WITH ACCESSIBLE <br />DAMPER, MIN 6 SQ IN FREE VENT AREA, TIGHT FITTING FLUE <br />DAMPERS REQ'D. <br />k ALL GAS AND OIL COMBUSTION APPLIANCES HAVE A DIRECT <br />VENT OR FORCED DRAFT VENTING. <br />M. RECESSED LIGHTS ARE I.C, RATED, DOUBLE WALL CAN LIGHTS OR <br />WITHIN SEALED WPGWB BOX -IN. <br />n. CONTRACTOR TO PROVIDE I1) 161lx24" MINIMUM CRAWL SPACE <br />ACCESS INTO NEW CRAWL SPACE AREA THAT IS ACCESSIBLE <br />FROM EITHER THE OUTSIDE OR FROM THE EXISTING CRAWLSPACE <br />AREA. OTHERWISE CONTRACTOR IS TO PROVIDE (1) 18"x24" MINIMUM <br />CRAWL SPACE ENTRANCE THROUGH MAIN LEVEL FLOOR FRAMING <br />THAT ACCESSES NEW CRAWL SPACE AREA. <br />o. A CERTIFICATE IS REQUIRED TO BE POSTED WITHIN 3' OF THE <br />ELECTRICAL PANEL PER WSEC R401.3 AND INCLUDE THE <br />FOLLOWING: PREDOMINATE R-VALUES, U-VALUES OF <br />FENESTRATION, RESULTS FROM DUCT SYSTEM AND BUILDING <br />ENVELOPE AIR LEAKAGE TESTING, AND EFFICIENCIES OF <br />HEATING/COOLING/WATER HEATING EQUIPMENT. <br />p, A MIN OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN <br />INTERIOR AND EXTERIOR LIGHTING FIXTURES MUST BE <br />HIGH -EFFICIENCY LAMPS PER WSEC R404.1 <br />INSULATION <br />FOR SI: 1 FOOT = 304.8 MM, CI = CONTINUOUS INSULATION, INT = <br />INTERMEDIATE FRAMING <br />a. R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS, <br />WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN <br />THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE <br />COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE <br />A1014 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE <br />TABLE <br />b. THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE <br />SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION. <br />c, 1110/15/21 +TB" MEANS R-10 CONTINUOUS INSULATION ON THE <br />EXTERIOR OF THE WALL, OR R-15 CONTINUOUS INSULATION ON THE <br />INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A <br />THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL <br />AT THE INTERIOR OF THE BASEMENT WALL 1110/15/21 +TB" SHALL <br />BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE <br />INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS <br />INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL "TB" <br />MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT <br />WALL, <br />d, R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON <br />GRADE FLOORS. SEE R402,2,9.1. <br />e, THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE, <br />f. RESERVED. <br />9. RESERVED, <br />h. RESERVED, <br />i. THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE <br />INSULATION IS ON THE INTERIOR OF THE MASS WALL, <br />j RESERVED, <br />k. FOR SINGLE RAFTER- OR JOIST -VAULTED CEILINGS, THE INSULATION <br />MAY BE REDUCED TO R-38, <br />1. RESERVED. <br />m. INT. FRAMING INTERMEDIATE DENOTES STANDARD FRAMING 16 <br />I ) <br />INCHES ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF <br />R-10 INSULATION, <br />n, LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE <br />THICKNESS OF 3,5 INCHES ARE EXEMPT FROM THIS INSULATION <br />REQUIREMENT. <br />o, WHERE EXISTING FRAMING CAVITIES ARE EXPOSED DURING <br />CONSTRUCTION, THE CAVITIES MUST BE FILLED TO FULL DEPTH <br />WITH BATT INSULATION OR INSULATION HAVING AN EQUIVALENT <br />NOMINAL R-VALUE OF R-15 AT 2x4 WALLS OR R-21 AT 2x6 WALLS <br />PER WSEC 503:11 <br />M ECHAN ICAL/VENTI'LATION <br />it'y^sh z F�y'X'.yci. <br />'S <br />rv_.u��+iaa <br />0-1 <br />2-3 <br />4-5 <br />6-7 <br />>7 <br />DWELLING UNIT <br />FLOOR AREA <br />SQUARE FEET) <br />AIRFLOW IN CFM <br /><1500 <br />30 <br />45 <br />60 <br />75 <br />90 <br />1501-3000 <br />45 <br />60 <br />75 <br />90 <br />105 <br />3001-4500 <br />60 <br />75 <br />90 <br />105 <br />120 <br />4501-6000 <br />75 <br />90 <br />105 <br />120 <br />135 <br />6001-7500 <br />90 <br />105 <br />120 <br />135 <br />150 <br />>7501 <br />105 <br />120 <br />135 <br />1 <br />150 <br />165 <br />Vertical Fenestration (Windows and doors <br />Component <br />Description <br />ACTUAL SIZE <br />:Width Height Sill <br />Ref. U-f actor Qt. :Feet, Inch Feet Inch Feet1nch <br />i <br />• ! <br />r! � <br />� • <br />i 1 <br />i 1 <br />A <br />• <br />i� <br />1 <br />IMMMMAIIINIMM <br />MMMMMMM <br />mmmmmmm <br />mmmmmmm <br />w .hum ofVertical Fenestration Area and UA <br />Vertical Fenestration Area Weighted U = UAj'Area <br />SAFETY GLAZING FOR EXISTING OPENING REPLACEMENT: <br />1, GLAZING IN DOORS: SAFETY GLAZING IS REQUIRED IN FIXED AND <br />OPERABLE PANELS OF SWINGING, SLIDING, AND BIFO'LD DOORS. SAFETY <br />GLAZING IS NOT REQUIRED IN A DOOR IF THE GLAZED OPENINGS DO <br />NOT ALLOW THEPASSAGE OF A 3 INCH SPHERE, OR THE GLAZING IN <br />THE DOOR IS DECORATIVE <br />2, GLAZING ADJACENT TO DOORS: GLAZING ADJACENT TO DOORS IS <br />REQUIRED I THE FOLLOWING LOCATIONS IF THE BOTTOM EDGE OF <br />EQU ED N E G <br />THE GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING <br />SURFACE: WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IF <br />GLAZING IS IN THE SAME PLANE AS THE DOOR, OR IF GLAZING IS IN <br />A WALL PERPENDICULAR TO THE DOOR WITHIN 24 INCHES ON THE Al <br />HINGE SIDE OF AN INSWING DOOR SAFETY GLAZING IS NOT REQUIRED <br />WINDOW & DOOR SCHEDULE NOTES: <br />Area <br />L <br />1. XO = SLIDER, SH = SINGLE HUNG, DH = DOUBLE HUNG, FIX = <br />PICTURE, C = CASEMENT <br />2. IF CONTRACTOR DECIDES TO REPLACE WINDOWS, THEY MUST <br />MEET ENERGY PERFORMANCE STANDARDS,HEAT TREATMENT <br />REQUIREMENTS AND EGRESS. <br />3, ALL WINDOWS SHALL BE NFRC CERTIFIED. <br />4. CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT <br />REQUIREMENTS WITH WINDOW & DOOR MANUFACTURER <br />5. EGRESS WINDOWS SIZED FOR '!MILGARD STYLE LINE" SERIES <br />WINDOWS, CONTRACTOR TO VERIFY EGRESS REQUIREMENTS IF A <br />DIFFERENT MANUFACTURER / MODEL IS CHOSEN, <br />IF THERE IS AN INTERVENING <br />A D A PM R S OTHER <br />WALL OR <br />PERMANENT BARRIER BETWEEN <br />WASHINGTON STATE ENERGY CREDIT CALCULATION; <br />THE DOOR AND THE GLAZING. <br />1. 545 SF OF NEW HEATED FLOOR AREA. 1.5 CREDITS REQ'D. <br />3. GLAZING IN WINDOWS; SAFETY <br />GLAZING <br />IN WINDOWS IS REQUIRED IF <br />THE INDIVIDUAL PANEL MEETS <br />ALL OF <br />THE FOLLOWING REQUIREMENTS; <br />ENERGY CREDITS CHOSEN: <br />• EXPOSED AREA OF THE INDIVIDUAL <br />PANEL IS GREATER THAN 9 <br />SQUARE FEET, <br />5a: EFFICIENT WATER HEATING 5a: <br />• THE BOTTOM EDGE OF THE <br />GLAZING <br />IS LESS THAN 18 INCHES <br />0.5 PTS <br />FROM THE FLOOR <br />ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN <br />• THE TOP EDGE OF THE GLAZING IS <br />MORE THAN 36 INCHES ABOVE <br />ALL <br />THE HOUSE SHALL BE R TE T 1.75 G 0 LES . <br />THE FLOOR, LAVATORY FAUCETS SHALL BE RATED AT 1,0 GPM OR LESS. <br />• THERE IS A WALKING SURFACE WITHIN 36 INCHES, MEASURED <br />HORIZONTALLY, FROM THE GLAZING 5c: EFFICIENT WATER HEATING 5c: <br />EXCEPTIONS 1.5 PTS <br />+ DECORATIVE GLAZING GAS WATER HEATER WITH A MINIMUM EF OF 0.91 <br />* WHERE A HORIZONTAL RAIL CAPABLE OF RESISTING 50 PLF <br />F FORCE WITHOUT MAKING CONTACT WITH THE GLASS IS <br />SEGMENT <br />0 <br />INSTALLED ON THE ACCESSIBLE SIDE OF THE GLAZING 34-38 <br />FACTOR <br />4 3 <br />2 <br />1.5t1,3 <br />1.0 <br />INCHES ABOVE WALKING SURFACE. <br />4, GLAZING IN RAILINGS AND GUARDS: ALL GLAZING IN GUARDS AND <br />1_, LOCAL EXHAUST SHALL BE POVIDED IN EACH KITCHEN, BATHROOM, <br />RAILINGS, INCLUDING STRUCTURAL BALUSTER PANELS AND <br />WATER CLOSET, LAUNDRY ROOM, INDOOR SWIMMING POOL, SPA, AND OTHER <br />NONSTRUCTURAL IN -FILL PANELS, IS REQUIRED TO BE SAFETY GLAZING. <br />ROOMS WHERE WATER VAPOR OR COOKING ODOR IS PRODUCED, LOCAL <br />5, GLAZING AND WET SURFACE: GLAZING IN WALLS, ENCLOSURES, OR <br />EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE CAPACITY TO EXHAST <br />FENCES AROUND SHOWERS, BATHTUBS, POOLS, HOT TUBS, SPAS, SAUNAS, <br />THE MINIMUM AIR FLOW RATE DETERMINED IN ACCORDANCE WITH TABLE <br />AND STEAM ROOMS WHERE THE BOTTOM EDGE OF THE GLAZING IS <br />IRC M1507.4, <br />LESS THAN 60 INCHES FROM THE STANDING OR WALKING SURFACE IS <br />• KITCHENS = 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS, <br />REQUIRED TO BE SAFETY GLAZING. SAFETY GLAZING IS NOT REQUIRED <br />• BATHROOMS/TOILET ROOMS, LAUNDRY ROOMS, INDOOR SWIMMING POOL <br />WHERE THE GLAZINGIS MORE THAN 60 INCHES, HORIZONTALLY, FROM <br />ROOMS, SPA ROOMS = 50 CFM INTERMITTENT OR 20 CFM <br />THE EDGE OF THE WATER <br />CONTINUOUS. <br />6, REFER TO IRC SECTION 312.2 FOR ADDITIONAL REQUIREMENT <br />• EXCEPTION: WHERE A RANGE HOOD OR DOWN DRAFT EXHAUST FAN <br />IS USED TO SATISFY THE LOCAL EXHAUST REQUIREMENTS FOR <br />KITCHENS, THE RANGE HOOD OR DOWN DRAFT EXHAUST SHALL NOT <br />BE LESS THAN 100 CFM AT .10 INCHES WATER GAUGE <br />• LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL <br />SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS, <br />2. WHOLE -HOUSE VENTILATION USING EXHAUST FANS MUST COMPLY WITH: <br />• IRC M1507.3.2: 24HR INTERMITTENT WHOLE -HOUSE SWITCH TO BE <br />INSTALLED TO CONTROL WHOLE -HOUSE FAN INTERMITTENTLY PER <br />TABLE M1507.3.3I2), LABEL TO BE AFFIXED TO THE CONTROL THAT <br />READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)", <br />OPERATING INSTRUCTIONS SHALL BE PROVIDED BY INSTALLER, <br />• IRC M1507.3.4A FAN MUST HAVE A FLOW RATING AT 0,25 INCHES <br />WATER GAUGE <br />• M1507.3,42; FANS WITHIN 4 FEET OF INTERIOR GRILLE SHALL HAVE <br />A BONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES1 WATER <br />GAUGE, <br />• IRC M15OT3,4,4 EACH HABITABLE SPACE SHALL BE PROVIDED WITH <br />OUTDOOR AIR INLETS OR OPERABLE WINDOWS WITH AN OPENABLE <br />AREA NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF <br />OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE <br />M1507.3.3(1), WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM <br />EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE <br />AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING <br />DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. <br />DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE <br />SURFACE OF THE FINISH FLOOR COVERING <br />3, DUCTS MUST BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33 USING <br />THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED, DUCT TIGHTNESS MUST <br />BE VERIFIED BY EITHER A POST-CONSRUCTION TEST OR ROUGH - IN TEST <br />PER WSEC R403,3.3, TOTAL LEAKAGE MUST BE LESS THAN OR EQUAL TO <br />4 CFM PER 100 SQ-FT OF CONDITIONED FLOOR AREA WHEN TESTED AT <br />A PRESSURE DIFFERENTIAL OF 0,1" W.G 125 PA) ACROSS THE ENTIRE <br />SYSTEM <br />4, PER IRC M1503,41 IF THE EXHAUST HOOD IN THE KITCHEN HAS A <br />CAPACITY IN EXCESS OF 400 CFM, IT MUST BE MECHANICALLY OR <br />NATURALLY PROVIDED WITH MAKEUP AIR AT A RATE OF APPROXIMATELY <br />EQUAL TO THE EXHAUST TO THE EXHAUST AIR RATE, SUCH MAKE UP AIR <br />SYSTEMS MUST BE EQUIPPED WITH NOT LESS THAN <br />ONE DAMPER, EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN <br />ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS WHEN <br />THE EXHAUST SYSTEM OPERATES, <br />5. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A <br />CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 <br />SQ. INCHES SHALL BE PROVIDED IN THE CLOSET ENCLOSURE OR MAKEUP <br />AIR SHALL BE PROVIDED BY OTHER APPROVED MEANS PER SMC 504,6, <br />CITY � = E TT <br />REVIEWED FOR PE 11` <br />P30 <br />YEN DESIGN INC. <br />206.432.1111 <br />WWW.YENDES.COM <br />ENGINEER STAMP <br />_l <br />w <br />W <br />2 <br />Ix W <br />> <br />Q <br />o <br />00 <br />Q <br />X <br /><C <br />Z W <br />5 <br />0 �• <br />W <br />F-- <br />w <br />N <br />W <br /><t N <br />N <br />w <br />06 W <br />W <br />W 0 <br />J <br />� 0 <br />O <br />� <br />0 <br />Z <br />� <br />U <br />Q 0 <br />U <br />W 0 <br />W Z <br />W 5 <br />0 <br />JOB NO. <br />20-141 <br />HALF SCALE <br />11x17 <br />FULL SCALE <br />22x34 <br />SHEET <br />OF 10 <br />