Laserfiche WebLink
A <br />UNDER —FLOOR VENT CALL. <br />1012 SQ-FT = 6,75 SQ-FT OR 972 SQ-IN OF CRAWL SPACE <br />150 SQ-FT <br />VENTS FOR TOTAL CRAWL SPACE, <br />PROPOSED MAIN FLOOR PLAN <br />22x SCALE 1 /4" = l °—O" <br />11 xl 7, SCALE 1 /8" ` 1 o—Opo <br />MECHANICAL WHOLE HOUSE VENTILATION SYSTEM <br />TYPE <br />WHOLE HOUSE FAN <br />MIN, CFM = 60 AT 0,25" WG (IRC TABLE M1507,3,3�1�J <br />jBASED ON 1554 S,F, FLOOR AREA & 3 BEDROOMS) <br />jDAILY FRACTION OPERATION TIME= 75%, FACTOR = 1.3J <br />INTERMITTENT CFM = 60 -)�, 1,3 = 78 <br />*WHOLE HOUSE FANS LOCATED 4 FT, OR LESS FROM INTERIOR <br />GRILLE TO HAVE A SONE RATING OF 1,0 OR LESS MEASURED AT <br />0.1" WG <br />c ?A <br />1, BEARING WALLS TO BE REMOVED <br />2. WINDOW OR DOOR TO BE INFILLED PER SHEET A1.1 <br />INSULATION AND FENESTRATION REQUIREMENTS, SEE <br />1 LAE.1 FOR BALANCE OF INFO, <br />3. RESERVED <br />4, TANK -LESS WATER HEATER WO MIN, EF OF 0,91, <br />5, CRAWL SPACE GAS FURNACE <br />6, NEW POST PER STRUCT„ <br />7, NEW 6x6 POST PER STRUCT, <br />8, RESERVED. <br />9, RESERVED, <br />10, RESERVED, <br />11. PROVIDE 4x6 HF#2 HEADER w/ 012x TRIMMER & (2�2x <br />KING STUD. SEE 2/A5,1, <br />12. RESERVED, <br />15. NEW STAIR & GUARDRAIL, SEE 5/A5J & 6/A5.1 FOR <br />DETAIL <br />14. RESERVED. <br />15, RESERVED, <br />16. 78 CFM INTERMITTENT WHOLE HOUSE FAN AT 0,25" <br />WATER GAUGE WITH A SONE RATING OF 1,0 OR LESS <br />MEASURED AT 01 INCHES WATER GAUGE, REFER TO <br />CALCULATION ON THIS SHEET <br />17, NEW WOOD STAIR AND CONC, LANDING. SEE DETAIL <br />/A5J & 7/A51 <br />18, EXISTING PERIMETER WALL CRAWLSPACE ACCESS, <br />CONTRACTOR TO VERIFY MIN. 161lx24" OPENING, <br />hp <br />f <br />I � �v. <br />�} Td MAIN <br />�MJ PLAN <br />NEW STUD WALL, SEE 1/A5,1 FOR FRAMING INFO, <br />z <br />Lu <br />l <br />EXISTING WALL TO REMAIN <br />EXISTING STRUCTURE TO BE REMOVED <br />Lu <br />SD SMOKE DETECTOR <br />Lu Lu <br />uj <br />---- --� <br />INDICATES REFERENCE TO KEYNOTES SEE KEYNOTES ON <br />Lu <br />� <br />THIS SHEET FOR BALANCE OF INFORMATION <br />CD CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP, <br />LU <br />EF EXHAUST FAN (INTERMITTENT) 50 CFM U,N,O. <br />SEE DOOR AND WINDOW SCHEDULE ON SHEET Al,1 FOR <br />DETAILED INFO, SEE 2/A5,1 FOR FRAMING INFO, <br />YEN DESIGN INC. <br />GENERAL NOTES <br />.1111 <br />A, <br />PLANS MUST BE APPROVED BY THE GOVERNING BUILDING <br />WVVW.YENDES.COM <br />OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK <br />COMMENCING, <br />APPROVAL <br />STAMP <br />B. <br />CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND <br />EXISTING SHEAR / BRACED WALL LOCATIONS BEFORE REMOVING <br />ANY WALLS, STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD <br />BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING <br />INSPECTOR, YEN DESIGN IS TO BE CONTACTED IF ACTUAL <br />EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS <br />AFTER CEILING WALL COVERINGS ARE REMOVED, <br />C, <br />SEE SHEET All FOR COMMON CODE REQUIREMENTS, <br />D. <br />CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL <br />LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO <br />ENGWEER STAMP <br />SLEEPING AREAS, <br />E, <br />SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF - <br />THE DWELLING AND WITHIN EACI-I SLEEPING AREA, DIRECT <br />WIRING REQUIRED <br />F, <br />VERIFY WINDOW & DOOR ROUGH OPENING SIZES WITH WINDOW & <br />DOOR MANUFACTURER, <br />G, <br />ALL DIMENSIONS TO STUD WALL, <br />H, <br />CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO <br />CONSTRUCTION. <br />I. <br />CONTRACTOR TO DETERMINE & VERIFY ALL WASTE DIVERSION <br />REQUIREMENTS PER THE LOCAL JURISDICTION, CONTRACTOR MAY <br />BE REQUIRED TO REQUEST LEED REPORTS FROM RECEIVING <br />FACILITIES, <br />J. <br />DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3" OFF WALL <br />OR ON CENTER, AS APPROPRIATE. <br />K. <br />CONTRACTOR TO VERIFY EXHAUST POINTS ARE NOT LESS THAN <br />Lu <br />0 <br />3' FROM PROPERTY LINES, 3' FROM OPERABLE OPENINGS INTO <br />0 <br />u <br />THE BUILDING, AND 10' FROM MECHANICAL AIR INTAKES. <br />uj <br />z CN <br />cc <br />L, <br />EACH HABITABLE SPACE SHALL BE PROVIDED WITH OPERABLE <br />Lu <br />WINDOWS WITH AN OPENABLE AREA NOT LESS THAN 4 SQUARE <br />INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF <br />uj <br />OUTDOOR AIR, WINDOW IS TO HAVE SCREEN AND SHALL BE <br />0 <br />CONTROLLABLE AND SECURABLE, <br />c\l <br />> <br />< <br />I <br />N uj <br />JOB NO. 20-141 <br />MALE SCALE l l xl7 <br />FULL SCALE 22x34 <br />SKEET <br />OF10 <br />