Laserfiche WebLink
AREA 1 - MASTER SUITE PORTION; <br />572 sa-FT <br />300 SQ-FT <br />= 1,91 SQ-FT OR 275 SQ-IN OF NET CLEAR AREA ATTIC <br />300 <br />ATTIC VENTILATION: <br />UPPER ROOF VENTILATION <br />PROVIDE 50% OF TOTAL ATTIC SPACE VENT, 136 SQ-IN <br />AF50 ROOF JACK (1011XTIj = 50 SQ-IN EA: <br />PROVIDE (4� AF50 ROOF JACK ON THE UPPER PORTION OF <br />THE ROOF AREA, VENTILATION PROVIDED = 200 SQ-IN (0,0 <br />ALSO PROVIDE a AF50 ROOF JACK AT THE LOWER PORTION <br />OF THE ROOF AREA. <br />AREA 2 - BONUS ROOM PORTION, <br />224 sa-F <br />300 sa-FT <br />T = 0.75 SQ-FT OR 106 SQ-IN OF NET CLEAR AREA ATTIC <br />30o <br />ATTIC VENTILATION, <br />hPROVIDE (4E AF50 ROOF JACK ON THE ROOF AREA, it <br />VENTILATION PROVIDED = 200 SQ-IN <br />PROPOSED ATTIC FLOOR PLAN <br />22x34: SCALE 1/4" = 1 °_O° <br />Ii I xl T: SCALE 1 /8" = 11 "_Soo <br />1, NEW STAIR & GUARDRAIL. SEE 5/A51 & 6/A51 FOR <br />DETAIL <br />2, REPLACE (Ej CEILING JOISTS W/ NEW & FLOOR <br />SHEATHING, SEE SHEET A4.1. & A4,2. <br />CiEIHEEEE)l <br />SD SMOKE DETECTOR <br />L / INDICATES REFERENCE TO KEYNOTES SEE KEYNOTES ON <br />THIS SHEET FOR BALANCE OF INFORMATION <br />CD CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP, <br />EF EXHAUST FAN (INTERMITTENTI 50 CFM U.N.O. <br />SEE DOOR AND WINDOW SCHEDULE ON SHEET All FOR <br />DETAILED INFO, SEE L/A51 FOR FRAMING INFO. <br />CONVERTED CONDITIONED SPACE (545 S.Fj <br />GENERAL NOTES <br />A, PLANS MUST BE APPROVED BY THE GOVERNING BUILDING <br />OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK <br />COMMENCING. <br />B. CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND <br />EXISTING SHEAR / BRACED WALL LOCATIONS BEFORE REMOVING <br />ANY WALLS, STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD <br />BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING <br />INSPECTOR. YEN DESIGN IS TO BE CONTACTED IF ACTUAL <br />EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS <br />AFTER CEILING WALL COVERINGS ARE REMOVED, <br />C. SEE SHEET All FOR COMMON CODE REQUIREMENTS. <br />D. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL <br />LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO <br />SLEEPING AREAS: <br />E, SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF <br />THE DWELLING AND WITHIN EACH SLEEPING AREA. DIRECT <br />WIRING REQUIRED, <br />F. VERIFY WINDOW & DOOR ROUGH OPENING SIZES WITH WINDOW 8, <br />DOOR MANUFACTURER: <br />G. ALL DIMENSIONS TO STUD WALL. <br />H. CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO <br />CONSTRUCTION. <br />I. CONTRACTOR TO DETERMINE & VERIFY ALL WASTE DIVERSION <br />REQUIREMENTS PER THE LOCAL JURISDICTION, CONTRACTOR MAY <br />BE REQUIRED TO REQUEST LEER REPORTS FROM RECEIVING <br />FACILITIES. <br />J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3" OFF WALL <br />OR ON CENTER, AS APPROPRIATE, <br />K. CONTRACTOR TO VERIFY EXHAUST POINTS ARE NOT LESS THAN <br />3' FROM PROPERTY LINES, 3' FROM OPERABLE OPENINGS INTO <br />THE BUILDING, AND 10' FROM MECHANICAL AIR INTAKES, <br />L EACH HABITABLE SPACE SHALL BE PROVIDED WITH OPERABLE <br />WINDOWS WITH AN OPERABLE AREA NOT LESS THAN 4 SQUARE <br />INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF <br />OUTDOOR AIR, WINDOW IS TO HAVE SCREEN AND SHALL BE <br />CONTROLLABLE AND SECURABLE, <br />.� 4 F N F IEME y»wgo <br />;y° EV J U iN' 'i w?,.., D FOR E— R M j 7 <br />206.432.1111 <br />APPROVAL STAMP <br />E ,KNEE STAMP <br />co <br />LU <br />0 <br />w <br />F- <br />F- <br />I- <br />> <br />N <br />uj <br />cn <br />CL <br />CL <br />LL <br />JOB NO. <br />20-141 <br />HALF SCALE <br />11 x17 <br />SF9EET OF 10 <br />