My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9001 AIRPORT RD 2021-12-20
>
Address Records
>
AIRPORT RD
>
9001
>
9001 AIRPORT RD 2021-12-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 2:55:02 PM
Creation date
12/16/2021 7:24:35 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
9001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • • r • . • - - - • - - • • <br /> 2018 WSEC Requirements for Commercial Buildin, cluding Group R2,R3&R4 over 3 stories&all R1 -- . inistered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Demonstrate that proposed wattage per non- <br /> tradable surface type does not exceed <br /> maximum allowed wattage per non-tradable <br /> surface type(including base site allowance <br /> remaining after tradable allowance <br /> calculation);identify locations of non-tradable <br /> surfaces on plans;provide WSEC exterior <br /> lighting compliance reports <br /> LIGHTING ALTERATIONS <br /> YES C503.6.1 Interior and parking Where>_50%of existing luminaires in an <br /> garage lighting interior space or parking garage are replaced; <br /> fixture alterations indicate compliance path(building area or <br /> space-by-space method);include all new and <br /> existing-to-remain luminaires in WSEC <br /> interior lighting compliance reports;indicate <br /> proposed lighting wattage does not exceed <br /> maximum allowed per compliance path <br /> NA Where<50%of existing luminaires in an <br /> interior space or parking garage are replaced; <br /> indicate total existing lighting wattage in each <br /> space prior to alteration;include all new and <br /> existing-to-remain luminaires in WSEC <br /> interior lighting compliance reports;indicate <br /> proposed total lighting wattage in alteration <br /> area does not exceed total existing lighting <br /> wattage prior to alteration <br /> NA Where>50%of existing exterior lighting <br /> wattage is replaced;include all new and <br /> existing-to-remain luminaires in WSEC <br /> exterior lighting compliance reports;indicate <br /> proposed total exterior lighting wattage does <br /> not exceed maximum allowed <br /> NA Where<50%of existing exterior lighting <br /> wattage is replaced;indicate total existing <br /> lighting wattage prior to alteration;include all <br /> new and existing-to-remain luminaires in <br /> WSEC interior exterior compliance reports; <br /> indicate proposed total exterior lighting <br /> wattage does not exceed total existing wattage <br /> prior to alteration <br /> NA C503.6.2 Interior lighting Where new wiring is installed to serve new <br /> wiring and circuiting interior luminaires and/or luminaires are <br /> alterations relocated to a new circuit;indicate manual <br /> and automatic lighting controls are provided <br /> i (as applicable)-manual(C405.2.3): <br /> occupancy sensor(C405.2.1);light reduction <br /> (C405.2.3);daylight responsive(C405.2.4); <br /> II specific application(C405.2.5) <br /> NA Where new wiring is installed to serve new <br /> exterior luminaires and/or luminaires are <br /> relocated to a new circuit;indicate automatic <br /> lighting controls are provided(C405 2.6) <br /> Page 7/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.