Laserfiche WebLink
• • • • • - — - • •• - - , • - • <br /> 2018 WSEC Requirements for Commercial Buildin cluding Group R2,R3&R4 over 3 stories&all R1 -- A. inistered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C405.6 Electrical Include electrical transformer schedule on <br /> transformers electrical plans;indicate transformer type, <br /> size,efficiency,or exception taken <br /> NA C405.11 Feeders and branch Provide documentation that demonstrates <br /> circuits maximum voltage drop across feeders and <br /> branch circuits does not exceed 5% <br /> NA C405.7 Dwelling unit Indicate on electrical plans that each dwelling <br /> electrical energy unit in Group R-2 has a separate electrical <br /> consumption energy meter <br /> NA C405.8 Electric motor Include all motors,including fractional hp <br /> efficiency motors,in electric motor schedule on <br /> electrical plans;indicate motor type, <br /> horsepower,rpm,rated efficiency,or <br /> exception applied <br /> NA C405.9.1 Elevator cabs For luminaires in each elevator cab,provide <br /> calculations that demonstrate average efficacy <br /> is not less than 35 lumens per watt <br /> NA For elevators that do not have an integral air <br /> conditioning system,indicate rated watts per <br /> cfm for elevator cab ventilation fans do not <br /> exceed 0.33 watts per cfm <br /> NA Indicate automatic controls that de-energize <br /> lighting and ventilation fans when elevator is <br /> stopped and unoccupied for a period of 15 <br /> minutes or more <br /> - I <br /> NA C4059.2 Escalators and Indicate escalators comply with ASME <br /> moving walks A 17.1/CSA B44;automatic controls are <br /> configured to reduce operational speed to the <br /> minimum permitted when not in use <br /> N A t 4 5 9.3 Regenerative drive Indicate all one-way down or reversible <br /> escalators are provided with a variable <br /> frequency regenerative drive <br /> DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING(CX) <br /> NA C408.4 Scope of electrical Indicate that all electrical systems <br /> power and lighting (receptacles,transformers,motors,vertical <br /> systems and horizontal transportation)for which the <br /> commissioning WSEC requires control functions and/or <br /> configuration to perform specific functions <br /> are required to be commissioned <br /> NA Where total building lighting Ioad is>20 kW, <br /> or where total lighting load of luminaires <br /> requiring daylight sensing and/or occupancy <br /> control>10 kW,indicate that all automatic <br /> lighting control systems are required to be <br /> commissioned;or provide building lighting <br /> power calculation demonstrating eligibility for <br /> exception <br /> NA C405.13 Commissioning Indicate Cx requirements in plans and <br /> C408.1.I requirements in specifications for all applicable electrical and <br /> C408.1.2 construction lighting control systems per C408 <br /> C408.1.4.2 documents <br /> C 103.6.3 <br /> Page 9/10 <br />