My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9001 AIRPORT RD 2021-12-20
>
Address Records
>
AIRPORT RD
>
9001
>
9001 AIRPORT RD 2021-12-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 2:55:02 PM
Creation date
12/16/2021 7:24:35 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
9001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • • T • • • - - ' • I • • ' <br /> 2018 WSEC Requirements for Commercial Buildin• cluding Group R2,R3&R4 over 3 stories&all R1 -- •. inistered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Provide calculation of lighting power density <br /> of total egress lighting <br /> NA If total egress lighting power density is greater <br /> than 0.02 W/sq.ft.,indicate on plans egress <br /> fixtures requiring automatic shut-off during <br /> unoccupied periods <br /> NA Indicate method of automatic shut-off control <br /> NA C405.4.1 Lighting control of Indicate that exempt interior lighting <br /> C405.4.2 exempt interior equipment and lighting located within spaces <br /> lighting that are eligible for a lighting power <br /> exemption are controlled independently from <br /> non-exempt and general area lighting <br /> NA C405.2.6 Exterior lighting For decorative exterior lighting,indicate on <br /> controls plans automatic daylight shut-off controls,or <br /> exception taken <br /> NA For exterior lighting that is not decorative, <br /> indicate on plans automatic daylight or time- <br /> switch shut-off controls and setback controls; <br /> or indicate exception taken <br /> NA For lighting requiring setback controls, <br /> include control sequence that reduces lighting <br /> power by at least 30%between 12am-6am,or <br /> from 1 hour after closing to 1 hour before <br /> opening,or based upon motion sensor <br /> NA For building facade and landscape lighting, <br /> indicate control sequence for shut-off control <br /> is based on dawn-to-dusk and business <br /> opening/closing schedule;indicate whether <br /> automatic or time switch controls will be <br /> provided for this function <br /> NA C405.5.2 Lighting control of Indicate that exempt exterior lighting and <br /> exempt exterior lighting located within exterior areas/surfaces <br /> lighting that eligible for a lighting power exemption <br /> are controlled independently from non- <br /> exempt exterior lighting <br /> NA C405.5.4 Exterior gas-fired Indicate ignition system is a method other <br /> lighting appliances then continuously burning pilot light <br /> NA C405.2.7 Area controls- Indicate location(s)of master control <br /> Master control switch(es)intended to control multiple <br /> switches and circuit independent switches;circuit breaker may not <br /> power limit be used as a master control switch <br /> NA Verify that no 20 amp circuit controlled by a <br /> single switch or automatic control is loaded <br /> beyond 80% <br /> ADDITIONAL EFFICIENCY CREDIT-ENHANCED INTERIOR LIGHTING CONTROLS <br /> Page 4/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.