My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9001 AIRPORT RD 2021-12-20
>
Address Records
>
AIRPORT RD
>
9001
>
9001 AIRPORT RD 2021-12-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 2:55:02 PM
Creation date
12/16/2021 7:24:35 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
9001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•. 0 9 Y • ll 0 - - - • I - - � • • U <br /> 2018 WSEC Requirements for Commercial Buildin cluding Group R2,R3&R4 over 3 stories&all R1 -- • inistered by©2021 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C406.4 Enhanced digital To comply with additional efficiency credit, <br /> lighting controls indicate on plans that interior lighting fixtures <br /> are configured with all of the following <br /> control functions,as applicable: 1)Each <br /> fixture is individually addressed,or exception <br /> taken;2)Fixtures are configured for <br /> continuous dimming;3)No more than eight <br /> fixtures are controlled by a single daylight <br /> sensor;4)In enclosed and open office areas, <br /> illumination levels of overhead general area <br /> lighting is configured to be individually <br /> adjusted by occupants <br /> NA Include calculations that demonstrate the total <br /> lighting power of all interior lighting fixtures <br /> configured with enhanced lighting controls is <br /> no less than 90%of the total interior lighting <br /> power for the area the enhanced lighting <br /> controls credit is being applied to <br /> INTERIOR LIGHTING POWER&EFFICACY <br /> YES C405.4.1 Total connected Include all luminaires in interior lighting E0.01 <br /> C405.4.2 interior lighting fixture schedule;indicate fixture types,lamps, <br /> power ballasts,and manufacturer's watts per fixture <br /> for the installed lamp <br /> NA Identify spaces eligible for lighting power <br /> exemption on plans and in WSEC interior <br /> lighting compliance reports;indicate the <br /> exception applied <br /> NA ' Identify lighting equipment eligible for <br /> lighting power exemption in fixture schedule <br /> and in WSEC interior lighting compliance <br /> reports;indicate the exception applied <br /> NA C405.1 Lighting in dwelling For all installed luminaires,include lamp type <br /> C405.1.1 units(multifamily) and number of lamps in lighting fixture <br /> schedule;for lamps that are not LED,T-8 or <br /> small diameter fluorescent,indicate efficacy <br /> of other lamp types is 65 lumens per watt or <br /> greater <br /> NA For all installed luminaires,indicate in <br /> lighting fixture schedule whether complying <br /> via lighting power density or by qualifying <br /> lamp type;if by lamp type,include number of <br /> lamps <br /> NA For all installed luminaires,indicate in <br /> lighting fixture schedule whether complying <br /> via lighting power density or by qualifying <br /> lamp type;if by lamp type,include number of <br /> lamps <br /> INTERIOR LIGHTING POWER CALCULATION-INDICATE COMPLIANCE PATH TAKEN <br /> NA C405.4.2.1 Building Area Demonstrate that total proposed wattage per <br /> Method building area does not exceed maximum <br /> allowed wattage per building area;identify <br /> locations of building areas on plans;provide <br /> WSEC exterior lighting compliance reports <br /> Page 5/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.