5/28/2021 Page 2 <br /> City of Everett /� <br /> 11:53:29AM <br /> INSPECTION ACTIVITY REPORT <br /> 1/18/2019 1/18/2019 BLDG TMB CORRECTION SEE NOTES (1/18/2019 11:59 AM TMB) <br /> 01-CONSULTATIO 1.Lateral support concerns at the east side <br /> of structure.Observed unbraced post and <br /> pier foundation elements.Please consult <br /> with structural engineer to produce <br /> solution/explanation. <br /> 2.West shearwall is not constructed per <br /> approved plan.Please consult with <br /> structural engineer about revisions and <br /> solutions. <br /> 3.Untreated wood is continuing to be used <br /> in close proximity to soils.See IBC sections <br /> 23.12.1 thru 2304.12.7 for code <br /> requirements. <br /> 4.Ledger bolts at balcony framing are too <br /> short and or missing supporting structure in <br /> several locations.correct as per approved <br /> plan. <br /> OBSERVATIONS Within Apartment Units: <br /> Damaged and defective T bar ceilings, <br /> mechanical equipment,electrical wiring, <br /> plumbing,fire resistive plaster is damaged <br /> and missing between apt.units and <br /> elsewhere. <br /> Damaged and defective mechanical <br /> equipment observed, (fuel burning hot <br /> water heaters,heating and cooking <br /> appliances) <br /> Please provide a comprehensive proposal <br /> to correct the many deficiencies within this <br /> structure. <br /> (1/18/2019 12:04 PM TMB) <br /> Contact person:Fabian @ 206 280-1484 <br /> 3/22/2019 3/22/2019 BLDG DWF CORRECTION Inspection pending City of Everett <br /> 08-FRAMING Engineer,James Bronder review of <br /> contractors revision to plans. <br /> 5/31/2019 5/31/2019 BLDG DWF PARTIAL APPR Framing for exterior of building only. <br /> 08-FRAMING Subject to-installing 4"x4"posts 6' on <br /> center(west wall)as per revised plans. <br /> Provide letter for 6"x 12"beams,earth to <br /> wood separation<12"R317.1 needs to be <br /> pressured treated. <br /> Install-seismic connections(brackets) <br /> stairstringers to floor framing. <br /> Ok to install siding,will inspect above <br /> corrections on next building inspection. <br /> 12/4/2019 12/4/2019 BLDG 14-OTHER DWF NO ACCESS <br /> 12/5/2019 12/5/2019 BLDG 14-OTHER DWF OTHER <br /> 1/8/2020 1/8/2020 BLDG DWF OTHER (1/8/2020 1:30 PM DWF) <br /> 01-CONSULTATIO Cosultation for fire protection-penatration. <br /> 2/4/2020 2/4/2020 BLDG BDGI OTHER Permit in process. <br /> 01-CONSULTATIO <br /> INSP12 <br />