• <br /> 3. The record drawings for this building do not indicate that the attic has been converted to habitable space, <br /> including the addition of a bedroom. The following requirements must be satisfied: <br /> a. Provide dimensions, area, ceiling height, and use for all rooms. See Sections R304 and R305. <br /> RE: Did change in A101 -2 Floor Plan Attic Proposal & A102 1 Section <br /> b. Hallways should comply with IRC Section R311.6. <br /> RE: Did change in A101 -2 Floor Plan Attic Proposal & A102 1 Section <br /> c. Sections and details for the stair construction. See IRC Section R311.7. Provide landings per Section <br /> R311.7.6. Show handrails complying with Section R311.7.8. Guards should be provided when required <br /> per Section R312.1 and detailed to limit openings per Section R312.1.3. Enclosed spaces under stairs <br /> should be covered with minimum 1/2"gypsum board. Provide artificial lighting per IRC Section R303.7. <br /> RE: Did change in A101 -2 Floor Plan Attic Proposal & A102 3 Staircase Section Proposal <br /> d. The location, type, size, and swing of all doors. The minimum clearance for all doors should be 6'-8" <br /> per IRC Section R305.1. Provide egress doors and landings per IRC Sections R311.1 through R311.3. <br /> Doors should not swing over stairs per Section R311.7.6. Note that the door at the bottom of the stairs <br /> does not comply. <br /> RE: Did change in A101 1 Floor Plan Proposal & 2 Floor Plan Attic Proposal & A102 1 Section <br /> e. Emergency escape windows should comply with IRC Section R310. <br /> RE: Did change in A101 -2 Floor Plan Attic Proposal <br /> f. Roof ventilation should be specified complying with IRC Section R806; a minimum 1"air gap should be <br /> provided between the insulation and roof sheathing per Section R806.3. Roofs with attic spaces should <br /> provide access hatches per IRC Section R807. <br /> RE: Did change in A101 -2 Floor Plan Attic Proposal & A102 -2 Wall Section <br /> g. The exterior of the building should be insulated to provide a thermal envelop complying with the 2015 <br /> WSEC. The thermal rating (i.e., Rmin, Umax) should be specified for each component of the building <br /> (e.g., walls, windows). Prescriptive values should be specified per WSEC Tables R402.1.1 or R402.1.3. <br /> The envelop should include the footings, below-grade walls, and slabs-on-grade. Alternatively, the <br /> thermal envelop may be designed per the Total UA method of WSEC Section R402.1.4; calculations <br /> substantiating the design should be included in the submittal documents. <br /> RE: Did change in A102 -2 Wall Section & Submitted Addition & submitted extra document <br /> Remodel Worksheet Results from WA State University excel file for WA State Code 2015 <br /> h. The building should be designed to comply with the additional energy efficiency requirements of WSEC <br /> Section R406. The architectural drawings should include a schedule listing the selected energy credits <br /> for the proposed project. <br /> RE: Did change Highlighted T1 3.5 Points for WA State Code 2015 <br />