My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6415 ELLIOTT WAY 2021-12-16
>
Address Records
>
ELLIOTT WAY
>
6415
>
6415 ELLIOTT WAY 2021-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 10:32:04 AM
Creation date
12/16/2021 10:31:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ELLIOTT WAY
Street Number
6415
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> EV E R E T T October 23,2020 <br /> WASHINGTON Linda Cloes <br /> lindacloes@gmail.com <br /> 4704 268th Ave NE <br /> Redmond,WA 98053 <br /> Owner: NW Elements Design, LLC <br /> Job Address: 6415 Elliott Way SE <br /> Plan Check No: B2006-036 <br /> RE: Building Permit Review Letter <br /> Dear Ms. Cloes, <br /> In response to the application for a building permit,the plans have been <br /> examined and you are advised that revisions may be necessary before a permit <br /> can be issued. Please review and respond to the comments below. <br /> 6. This comment has not been adequately addressed. Please cut the <br /> sections on the plan sheets and denote which direction the section is cut as <br /> those locations appear to be missing on the plans. For instance,the interior <br /> section appears to be cut at a stairway please denote the cut and direction on <br /> plan to which this is being cut. IRC R106.1.1. <br /> 7. This comment has not been adequately addressed. The location of the <br /> egress windows with respect to the floor level does not appear to have been <br /> noted nor have construction details for window wells where the egress <br /> windows occur have been provided on the plans. Please revise drawings as <br /> required to demonstrate compliance with the window well requirements or <br /> demonstrate that a window well is not required at the egress windows. IRC <br /> R310.2 and its subsections. <br /> 9. This comment has not been adequately addressed. Exterior landings at <br /> these stairways do not appear to have been provided as noted in the response. <br /> Please add details for landings as required. IRC 311.7.6. <br /> 10. This comment has not been completely addressed. The Main Floor Plan <br /> PERMIT SERVICES 1st Floor)contains new stairs for the porch rebuild that does not contain details <br /> for items such as locating handrails nor connection details for installing the <br /> 9 3200 Cedar Street stairs to the updated deck construction. Please provide details to demonstrate <br /> Everett,WA 98201 compliance with these provisions. IRC R311.7, IRC R106.1.1. <br /> tak 425.257.8810 11. This comment has not been adequately addressed. Guardrails and their <br /> 425.257.8857 fax <br /> construction details for anchorage on the elevated deck have not been <br /> everetteps@everettwa.gov provided on the revised architectural set or on the new structural framing <br /> everettwa.gov/permits plans. IRC R507, R312 <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.