My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6415 ELLIOTT WAY 2021-12-16
>
Address Records
>
ELLIOTT WAY
>
6415
>
6415 ELLIOTT WAY 2021-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 10:32:04 AM
Creation date
12/16/2021 10:31:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ELLIOTT WAY
Street Number
6415
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> October 23,2020 <br /> Linda Cloes <br /> lindacloes@gmail.com <br /> 4704 268th Ave NE D . r<fr <br /> Redmond, WA 98053 ' <br /> Owner:NW Elements Design,LLC '� <br /> Job Address: 6415 Elliott Way SE <br /> Plan Check No: B2006-036 CITY OF FvERETT <br /> RE: Building Permit Review Letter Pe rm i 1 , et•vices <br /> Dear Ms. Cloes, <br /> In response to the application for a building permit,the plans have been examined and you are <br /> advised that revisions may be necessary before a permit <br /> can be issued. Please review and respond to the comments below. <br /> Hi James,please see my responses in blue below: <br /> 6.This comment has not been adequately addressed.Please cut the sections on the plan sheets <br /> and denote which direction the section is cut as <br /> those locations appear to be missing on the plans.For instance,the interior section appears to be <br /> cut at a stairway please denote the cut and direction on <br /> plan to which this is being cut. IRC R106.1.1. <br /> Section cut directions are now noted on the plan. <br /> 7.This comment has not been adequately addressed.The location of the egress windows with <br /> respect to the floor level does not appear to have been <br /> noted nor have construction details for window wells where the egress windows occur have been <br /> provided on the plans.Please revise drawings as <br /> required to demonstrate compliance with the window well requirements or demonstrate that a <br /> window well is not required at the egress windows.IRC <br /> R310.2 and its subsections. <br /> The sill height of 44 inches has been added to the new egress window in the basement <br /> bedroom. This will satisfy the requirement, and a window well is not needed. <br /> 9. This comment has not been adequately addressed.Exterior landings at these stairways do not <br /> appear to have been provided as noted in the response. <br /> Please add details for landings as required. IRC 311.7.6. <br /> Exterior landings have been added. The front deck landing is gravel, and the elevated rear deck <br /> is concrete. Both are the required 36 inches deep and stair width. <br /> 10. This comment has not been completely addressed.The Main Floor Plan(1st Floor)contains <br /> new stairs for the porch rebuild that does not contain details <br /> for items such as locating handrails nor connection details for installing the stairs to the updated <br /> deck construction.Please provide details to demonstrate <br /> compliance with these provisions.IRC R311.7,IRC R106.1.1. <br /> These details have been added to the notes sheet with references on the plans. <br />
The URL can be used to link to this page
Your browser does not support the video tag.