My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10115 HOLLY DR BLDG N OLIN FIELDS APTS 2021-12-16
>
Address Records
>
HOLLY DR
>
10115
>
OLIN FIELDS APTS
>
10115 HOLLY DR BLDG N OLIN FIELDS APTS 2021-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 2:43:05 PM
Creation date
12/16/2021 2:22:57 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10115
Unit
BLDG N
Tenant Name
OLIN FIELDS APTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3/12/2019 <br />12:50:53PM <br />City of Everett <br />INSPECTION ACTIVITY REPORT <br />Page 1 �� <br />_: <br />Permit No. M1811-118 Site Address 10115 HOLLY DR BLDG N <br />Applied 11/30/2018 Applicant RESTORATION SYSTEMS INC Lot <br />Approved 11/30/2018 Owner STANDARD JSP OLIN LLC Block <br />Issued 11/30/2018 Contractor RESTORATION SYSTEMS INC Tract <br />Parent Permit No. B1806-007 Description REPLACE BATH EXHAUST FANS, KITCHEN HOODS <br />Notes UNITS N102, N202, N302 <br />Scheduled <br />Completed <br />Tvpe <br />Insuector <br />Result Remarks <br />Insuector's Comments <br />12/3/2018 <br />12/3/2018 <br />MECH 05-OTHER <br />DXW <br />CORRECTION <br />Fireplace to be installed per manufacturers <br />spec and chimney per spec. <br />All exhaust fans and dryer duct and range <br />exhaust to be installed in a fire rated <br />system. <br />Laundry room required exhaust fan. <br />12/6/2018 <br />12/6/2018 <br />MECH 05-OTHER <br />DXW <br />CORRECTION <br />Fireplace framing to be to manufactering <br />spec. Metal flashing required chimney to be <br />installed to manufactering spec. Fire <br />protections system to be ok by plans <br />examiner at city turn architect fix to plans <br />examiner. <br />12/13/2018 <br />12/13/2018 <br />MECH 04-ROUGH <br />SDP <br />APPROVAL <br />Complete horizontal shafts for 1st and 2nd <br />IN <br />floor dryers (end blocking). <br />Fireplace framing and chimney OK to <br />cover. <br />No drywall over metal portion of fireplace, <br />use only non-combustible over the metal. <br />12/19/2018 <br />12/19/2018 <br />MECH 04-ROUGH <br />DXW <br />CORRECTION <br />1. Fireplace rough in ok. Floor 1 and 2 <br />IN <br />rough in mechanical ok. <br />2.On floor 3 unit N-302 Drew Martin at <br />city (plans examiner) must approve fire <br />rating for exhaust ducting in attic. <br />1/25/2019 <br />1/25/2019 <br />MECH 04-ROUGH <br />SDP <br />NOT READY <br />PM inspection requested <br />IN <br />Phone: 901-336-0883 <br />1/28/2019 <br />1/28/2019 <br />MECH 04-ROUGH <br />DXW <br />CORRECTION <br />(1/28/2019 11:41 AM DXW) <br />IN <br />Fire wrap on exh. to be installed to mfg. <br />spec. - no bare spots. <br />Inspector needs mfg spec. book for fire <br />wrap and dampers. <br />1/29/2019 <br />1/29/2019 <br />MECH 04-ROUGH <br />DXW <br />NO ACCESS <br />IN <br />INSP12 <br />a Y'iElut <br />
The URL can be used to link to this page
Your browser does not support the video tag.