Laserfiche WebLink
• <br /> STORM WATER SITE PLAN OCTOBER 23,2019 <br /> EMORYS ON SILVER LAKE PAGE 4 <br /> MR2: CONSTRUCTION STORMWATER POLLUTION PREVENTION <br /> Construction stormwater pollution prevention plan will be prepared for review and approval as <br /> part of the construction drawing submittal phase. Following is a conceptual SWPPP for the site. <br /> 1. CONSTRUCTION STORMWATER POLLUTION PREVENTION ELEMENTS <br /> A Construction Storm water Management Plan has been prepared as part of the construction <br /> drawings and is submitted for review and approval by the City of Everett. The 13 Required <br /> Elements are addressed as follows: <br /> Element#1: Preserve Vegetation/Mark Clearing Limits <br /> The construction plans delineate the limits of the clearing for the site. These will be located in <br /> the field prior to clearing taking place. <br /> Element#2: Establish Construction Access <br /> Access will be from the existing parking access from 120th Place SE. The access will be stabilized <br /> with rock construction entrance. <br /> Element#3: Control Flow Rates <br /> There should be little need to control flow rates during the parking lot construction as the area <br /> has been an impervious parking lot for many years. The storm system is an open pond and will <br /> be configured as a sedimentation pond during construction. It will be fully installed before any <br /> home construction begins. <br /> Element#4: Install Sediment Controls <br /> A construction sequence lists the schedule for installation of erosion control measures. <br /> Element#5:Stabilize Soils <br /> In planting areas the exposed soils will be stabilized with lawn and landscaping and parking <br /> areas stablilized by BMP C107 roadway base.Temporary stockpiles will be covered with plastic. <br /> Element#6: Protect Slopes <br /> There are no steep slopes on the property and proposed slopes will be limited to 2:1 maximum. <br /> Element#7: Protect Drain Inlets <br /> The catchbasins along 120th Place SE and 19th Avenue SE will be subject to potential runoff from <br /> the disturbed areas and will be protected with filter inserts. <br /> Element#8:Stabilize Channels and Outlets <br /> Outlet protection for the outlet to the pond will be used per BMP C209. <br /> Element#9: Control of Pollutants <br /> All pollutants, including waste materials and demolition debris, that occur onsite shall be <br /> handled and disposed of in a manner that does not cause contamination of stormwater. Good <br /> housekeeping and preventative measures will be taken to ensure that the site will be kept <br /> P:\Work\Projects\2018\18-141 Emory's\CE\DOCS\Final SSP 18-141.doc <br />