844 OLYMPIC BLVD 2022-01-20
>
Address Records
>
OLYMPIC BLVD
>
844
>
844 OLYMPIC BLVD 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:27:24 PM
Creation date
1/20/2022 3:21:50 PM
Metadata
Fields
Template:
Address Document
Street Name
OLYMPIC BLVD
Street Number
844
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> CITY OF EVERETT <br /> EVERETT Permit Services <br /> WASHINGTON <br /> October 23, 2019 <br /> Owner: Snitko <br /> Job Address: 844 Olympic Blvd. <br /> Plan Check No: CW1910-001 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Snitko, <br /> In response to the application for a building permit,the plans have been examined and you are advised that <br /> revisions are necessary before a permit can be issued. Please review and respond to the comments below. <br /> 1. The plans as drawn do not reflect the actual appearance of the structure. Please revise elevation <br /> drawings to show the actual appearance of the structure. <br /> 2. Revise site plan to show the dimensions of all structures, existing and proposed.Show location of <br /> heat pump on the site plan. <br /> 3. Provide tempered safety glass in hazardous locations as defined in section R308 IRC. Label tempered <br /> glass on floor plans. <br /> 4. Provide section drawing and/or details specific to this structure for the following; <br /> - Footing size, depth and reinforcing steel at new deck <br /> - Post to footing connection at deck <br /> - Post to beam connection at deck <br /> - Deck joist to beam connection and blocking at new beam <br /> - Ledger detail (elevation view showing edge distance, spacing and staggered placement) <br /> - Detail the enclosure for the recessed lights in the garage ceiling. <br /> 5. Show the location of all lateral connectors on the plan view of the new deck required by section <br /> R507 IRC. <br /> 6. All walls, posts,and beams supporting living space above the garage shall be covered with minimum <br /> %' Gypsum Wallboard.Show requirement on plans. <br /> 7. Provide detail of the connection of the railing system to the deck structure.Show blocking for <br /> connection of the railing system. <br /> 8. Show the location and size of all source specific ventilation including exhaust fan in new master <br /> bathroom and new range hood in Kitchen.All exhaust fans shall be ventilated to the exterior. <br /> 9. All spaces in the dwelling shall be labeled for the intended use of the space. All labels shall be <br /> unique to each space such as Bedroom#1, Bedroom#2, Dining Room, Living Room etc. <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.