844 OLYMPIC BLVD 2022-01-20
>
Address Records
>
OLYMPIC BLVD
>
844
>
844 OLYMPIC BLVD 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:27:24 PM
Creation date
1/20/2022 3:21:50 PM
Metadata
Fields
Template:
Address Document
Street Name
OLYMPIC BLVD
Street Number
844
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DECEMBER 7,2019 <br /> Owner:Snitko <br /> Job Address:844 Olympic Blvd. <br /> Plan Check No:CW1910-001 <br /> RE: Building Permit Review Letter <br /> Dear EVERETT BUILDING DEPARTMENT, <br /> RESPONSES below IN RED. <br /> 1. Provide details and/or section drawings for the construction of the vaulted ceilings in the <br /> Kitchen/Eating Area and the Living Room including the attachment of the rafters to the new hip <br /> beam in the living room. DRAWINGS ARE UPDATED WITH SECTIONS AND DETAILS FOR VAULTED <br /> CEILINGS. <br /> 2.Specify the size, species and grade of the new hip beam at the vaulted Living Room.SEE STRUCTURAL <br /> DRAWINGS Si <br /> 3. Identify the load path,to the foundation,for all new loading conditions created by vaulting the <br /> ceiling in the Kitchen and the ceiling in the Living Room.SEE STRUCTURAL DRAWINGS S1 AND SECTION <br /> DRAWINGS <br /> 4.The Ledger Details on sheet 1 show the floor joists as"I-joists". Please correct. LEGDER DETAIL IS A <br /> STANDARD DETAIL THAT REFERS"FLOOR JOISTS PER PLAN" (Doesn't necessarily match the plan) IT CAN <br /> BE EITHER I-JOIST OR SOLID WOOD.ADDITIONAL DRAWING ADDED FOR CLARITY <br /> 5.Specify the size,species and grade for all new headers installed at the new window locations, <br /> including but not limited to the Kitchen, Dining room,and the Master Bathroom.ALL NEW HEADERS ARE <br /> 4X10 D.F.#2 AS SPECIFIED IN DRAWINGS GENERAL COMMENT.ALL OTHER HEADERS AND BEAMS <br /> LABELED ON STRUCTURAL DRAWINGS. <br /> 6.Show the size and location of all existing, new and/or replaced windows on the floor plan. Label <br /> each window as"Existing","Existing, Replaced"or"New".ALL NEW WINDOWS ARE LABELED,SEE <br /> LEGEND AND DRAWINGS.ALL EXISTING OPENINGS WITH NEW WINDOWS ARE LABLED ON OLD <br /> ORIGINAL DRAWINGS PER THE LEGEND(RED LINE). <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.