Laserfiche WebLink
7.Show all interior partitions,doors, plumbing and mechanical components,appliances and stairs and <br /> label all spaces for the intended use with a unique label,such as Bedroom#2, Bedroom#3 etc.ALL NEW <br /> SPACES ARE LABELD ON NEW DRAWINGS,ALL OTHER DETAILS AND EXISTING ROOMS LABELED ON <br /> ORIGINAL DARWINGS. <br /> 8. Include all porches and landings at the exterior of the building on the corresponding floor plans.ALL <br /> PORCHES ARE SHOWN ON THE CORRESPONDING FLOOR PLANS <br /> 9. Revise application to include all new or replaced plumbing fixtures and mechanical equipment. NEW <br /> DRAWINGS AND ORIGINAL OLD DRAWINGS HAVE BEEN REDLINED TO SHOW new or replaced plumbing <br /> fixtures and mechanical equipment. <br /> 10. Provide section drawing of new infill walls at garage.Show all components including size and spacing <br /> of studs, pressure treated bottom plates and double top plates. DRAWINGS ARE UPDATED WITH <br /> SECTIONS AND DETAILS FOR VAULTED CEILINGS. <br /> 11.Show how the new vaulted areas of the ceiling/roof are provided with ventilation. DRAWINGS ARE <br /> UPDATED WITH SECTIONS AND DETAILS FOR VAULTED CEILINGS. <br /> 12.Specify the insulation installed in the new vaulted areas, minimum R-38 required with minimum 1" <br /> clear air space over insulation. DRAWINGS ARE UPDATED WITH SECTIONS AND DETAILS FOR VAULTED <br /> CEILINGS. <br /> 13. Provide gravity calculations for the new hip beam and rafters at the vaulted ceiling in the living <br /> room,the vaulted rafters at the Kitchen ceiling and for the new pressure treated beam supporting <br /> the new deck.SEE STRUCTURAL DRAWINGS S1 AND CALCULATIONS <br /> 14. Provide section drawing(s)for the deck construction including the attachment of the deck joists to <br /> the beam,solid blocking over the beam,decking material,guard attachment and blocking, rim joist <br /> and attachment and flashing.SEE LAYOUT DRAWINGS,SECTIONS,AND DETAILS <br /> 15. Provide on drawings,a ledger detail for bolt placement and edge distance for the deck ledger. (See <br /> Figure R507.2.1(1) IRC)ADDITIONAL DETAILS ADDED PER R507.2.1(IRC 507 ALSO ALLOWS RAILS AND <br /> GAURDS DESIGNED PER R301) EXISTING DECK ALUMINUM RAIL SYSTEM HAS BEEN DESIGNED BY THE <br /> MANUFACTURER TO MEET THESE REQUIREMENTS(ENOUGH CAPACITY TO RESIST: Uniform load of 50 <br /> Ibf/ft. (0.73 kN/m)applied in any direction. Concentrated load of 200 Ibf(0.89 kN)applied in any <br /> direction. Uniform and concentrated loads need not be assumed to act concurrently)....THEY HAVE BEEN <br /> APPROVED ON OTHER PROJECTS IN EVERETT. <br /> 16. Provide tempered safety glass in the windows adjacent to the bathtub in the new Master Bathroom, <br />