My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1315 PACIFIC AVE LUMEN APARTMENTS 2022-01-20
>
Address Records
>
PACIFIC AVE
>
1315
>
LUMEN APARTMENTS
>
1315 PACIFIC AVE LUMEN APARTMENTS 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:57:17 PM
Creation date
1/20/2022 3:56:41 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1315
Tenant Name
LUMEN APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
https://wseccompliancedocuments.com/print_project_summary_fo... <br /> LIGHTING COMPLIANCE SUMMARY • • <br /> 2015 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI Administered by:G2018 NEEA,All rights reserved <br /> Project Title Lumen Apartments 'For Building Department Use: I Date: Sep 18,2019 <br /> Project Address 1315 Pacific Ave <br /> Project&Applicant Everett,WA 98201 <br /> Information Applicant Name Matthew Waste <br /> Applicant Phone 206-405-2537 <br /> Applicant Email matt@sww-ai.com <br /> General Occupancy Mixed Use-Commercial+Group R building over 3 stories General Building Type Mid-Rise Apartment/Condo Building Cond.Floor Area 149,256 <br /> New Building or Project Cond.Floor Area 2,247 <br /> AReration <br /> General Project Types Alteration Addition Interior Lighting Floors Above Grade 4 <br /> Lighting Scope Lighting Scope Compliance Method Compliance Method 1-General <br /> Lighting Project Description <br /> Lighting Compliance Scope Project Type Interior/Exterior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Verification <br /> and Method (Interior includes both Interior&parking) Adjustment <br /> - <br /> Alteration Interior Lighting 50%or more replaced Building area No Calculation Adjustments allowed COMPLIES <br /> Additional Efficiency <br /> Options Included <br /> Project Title Lumen Apartments Date Sep 18,2019 <br /> Lighting Power Calculation ALTERATION-INTERIOR LIGHTING(50%or more replaced) Compliance Verification COMPLIES <br /> Compliance Method (Building area ILPA Calculation Adjustment I none <br /> Interior Lighting Power Allowance-Building Area <br /> Building Areas Gross Interior Area(SF) LPA(Watts/SF) Total Watts Allowed Total Proposed Watts - Compliance Status by <br /> (SF x LPA x 0.75) By Building Area Building Area <br /> Multifamily 2,247 0.41 921 590 COMPLIES <br /> Proposed Lighting Power Density <br /> Watts per Total Watts <br /> Fixture Type/Application Fixture ID Building Area New or Quantity of Fixtures,CLDs or Fixture,CLD or Total Linear Watts per Linear Proposed <br /> Existing-to-Remain Luminaires(#F) Luminaire(WpF) Feet(LF) Foot(WpLF) (#F x WpF)or <br /> (LF x WpLF) <br /> Individual Fixtures <br /> Direct/indirect pendant L-4 Multifamily New 7 20 140 <br /> Direct/indirect pendant LI Multifamily New 2 20 40 <br /> Direct/indirect pendant L2 Multifamily New 3 20 60 <br /> Recessed downlight L-5 Multifamily New 4 20 80 <br /> Suspended, L-7 Multifamily New 5 30 150 <br /> Wall-mounted L-6 Multifamily New 6 20 120 <br /> CLD=Current Limiting Device <br /> Project Title Lumen Apartments Date Sep 18,2019 • <br /> Proposed Fixtures Details [ALTERATION-INTERIOR LIGHTING(50%or more replaced) <br /> Fixture Type/Application 1111 Fixture II) Location in Documents LampNew or <br /> Typ PPType Building Area Existing-to-Remain <br /> Individual Fixtures <br /> Direct/indirect pendant L-4 A202 _ LED Multifamily New <br /> Future Description: Are these fixtures within a daylight zone?: <br /> Are specific application lighting controls required?: <br /> Direct/indirect pendant LI I A202 I LED Multifamily I New <br /> Fixture Description: Are these fixtures within a daylight zone?:No <br /> Are specific application lighting controls required?:None required <br /> Direct/indirect pendant L2 I A202 I LED Multifamily I New <br /> Fixture Description: Are these fixtures within a daylight zone?: <br /> Are specific application lighting controls required?: <br /> Recessed downlight L-5 I A202 I LED Multifamily I New <br /> Fixture Description: Are these fixtures within a daylight zone?: <br /> Are specific application lighting controls required?: <br /> Suspended L-7 I- A202 I LED Multifamily I New <br /> Fixture Description: Are these fixtures within a daylight zone?: <br /> Are specific application lighting controls required?: <br /> Wall-mounted L-6 I A202 1 LED Multifamily I New <br /> Fixture Description: 'Are these fixtures within a daylight zone?: <br /> Are specific application lighting controls required?: <br /> • <br /> 1 of 1 9/18/2019,9:21 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.