olio Development Design Strategies <br /> accordance with IRC R310 and its subsections. Please revise plans and details as required to provide <br /> such openings. <br /> ANSWER TO COMMENT 6: <br /> New egress windows have been added at the Master Bedroom and in Bedroom 2.The existing <br /> window in Bedroom 1 is adequate. See 1/A2,and Elevation drawings 1 and 3 on Sheet A4. <br /> 7. Sheets S-101 and S-105 show an office and bedroom, respectively in the same location.The room <br /> labels for the habitable spaces are inconsistent and appear to be a drafting error. Please clarify the <br /> room labels and revise as required. IRC R106.2. <br /> ANSWER TO COMMENT 7: <br /> See 1/A2 showing the correct designation of the space as Bedroom 2, not an office. <br /> 8. On sheet S-103, it is unclear if this basement area is to become habitable space. Please clarify <br /> and provide a floor plan that indicates the proposed use of the space or if is to become <br /> unoccupied space please note the area as such on the plans as this is unclear on the construction <br /> documents. Please note that habitable basements are subject to meeting the requirements of IRC <br /> R305 for ceiling heights and IRC R310 for emergency egress. <br /> ANSWER TO COMMENT 8: <br /> The Basement is Unoccupied Storage space.See 2/A1. <br /> 9. On sheet S-101, doors that lead to the exterior are required to have exterior landings.This <br /> appears to be missing from the construction drawings. Please revise drawings to indicate exterior <br /> landings as required per IRC R311.3. <br /> ANSWER TO COMMENT 9: <br /> See 1/A1 <br /> 10. The stairways on S-101 and S-102, do not appear to have handrails shown on the plans. Please <br /> indicate and locate handrails as required per IRC R311.7.8. <br /> ANSWER TO COMMENT 10: <br /> There are no new stairs in the project.The drawings referred to in this Comment have been <br /> removed. <br /> 11. Please locate and update smoke alarms and carbon monoxide detectors per IRC R314.2.2 and <br /> R315.2.2, respectively as these alarms and detectors are missing from the plans. Please revise <br /> drawings as required. <br /> ANSWER TO COMMENT 11: <br /> Please see 1/A3. 2/A3 and 3/A3 for notes indicating the required alarms and detectors. <br /> 12. Please address the local exhaust requirements for the kitchen, bathrooms,and laundry room <br /> as this appears to be missing from the plans. IRC M1507.4. <br /> ANSWER TO COMMENT 12: <br /> Please see drawings 2/A3 and 3/A3 for notes indicating local exhaust requirements for these <br /> rooms. <br /> Page g /7 <br />