Laserfiche WebLink
Geotechnical Engineering Evaluation NGA File No. 1031018 <br /> Multi-Family Residential Development April 19,2018 <br /> Everett,Washington Page 8 <br /> allowable bearing pressure is estimated to be less than 1-inch total and%-inch differential between adjacent <br /> footings or across a distance of about 20 feet,based on our experience with similar projects. <br /> Lateral loads may be resisted by friction on the base of the footing and passive resistance against the <br /> subsurface portions of the foundation. A coefficient of friction of 0.35 may be used to calculate the base <br /> friction and should be applied to the vertical dead load only. Passive resistance may be calculated as a <br /> triangular equivalent fluid pressure distribution. An equivalent fluid density of 200 pounds per cubic foot <br /> (pcf)should be used for passive resistance design for a level ground surface adjacent to the footing. This <br /> level surface should extend a distance equal to at least three times the footing depth. These recommended <br /> values incorporate safety factors of 1.5 and 2.0 applied to the estimated ultimate values for frictional and <br /> passive resistance, respectively. To achieve this value of passive resistance, the foundations should be <br /> poured"neat" against the native medium dense soils or compacted fill should be used as backfill against <br /> the front of the footing. We recommend that the upper one foot of soil be neglected when calculating the <br /> passive resistance. <br /> Retaining Walls <br /> We do not anticipate the need for retaining walls on this site;however,should basement walls or any other <br /> retaining walls be utilized,they should be designed and constructed as outlined hereon. The lateral pressure <br /> acting on subsurface retaining walls is dependent on the nature and density of the soil behind the wall,the <br /> amount of lateral wall movement which can occur as backfill is placed,wall drainage conditions,and the <br /> inclination of the backfill. For walls that are free to yield at the top at least one thousandth of the height of <br /> the wall(active condition), soil pressures will be less than if movement is limited by such factors as wall <br /> stiffness or bracing (at-rest condition). We recommend that walls supporting horizontal backfill and not <br /> subjected to hydrostatic forces,be designed using a triangular earth pressure distribution equivalent to that <br /> exerted by a fluid with a density of 40 pcf for yielding(active condition)walls,and 60 pcf for non-yielding <br /> (at-rest condition)walls. <br /> These recommended lateral earth pressures are for a drained granular backfill and are based on the <br /> assumption of a horizontal ground surface behind the wall for a distance of at least the subsurface height of <br /> the wall, and do not account for surcharge loads. Additional lateral earth pressures should be considered <br /> for surcharge loads acting adjacent to subsurface walls and within a distance equal to the subsurface height <br /> of the wall. This would include the effects of surcharges such as traffic loads,floor slab loads, slopes,or <br /> other surface loads. We could consult with the structural engineer regarding additional loads on retaining <br /> walls during final design,if needed. <br /> NELSON GEOTECHNICAL ASSOCIATES, INC. 91 <br />