My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 ROCKEFELLER AVE 2022-01-31
>
Address Records
>
ROCKEFELLER AVE
>
2720
>
2720 ROCKEFELLER AVE 2022-01-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2022 9:13:39 AM
Creation date
1/25/2022 1:14:32 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2720
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' ASBESTOS NORTHWEST LLC SURVEY REPORT ASBESTOS <br /> NORTHWEST <br /> 30620 Pacific Hwy S Suite 103 Federal Way,WA 98003 <br /> Tel:253 9414343 Fax:253 9414175 <br /> 5. Conclusions <br /> Within the 1960's and 1980's portions of the building asbestos containing materials <br /> were relatively minimal. <br /> Vermiculite fill was present in the exterior walls of this section and was sampled from the <br /> first floor north and west walls. <br /> Vinyl tiles and the associated mastic were found to contain asbestos. These were found in <br /> the hall outside the first floor locker rooms, as well as a nearby store rooms and the north <br /> west mechanical room office and the northwest stairwell. This represents a total of <br /> roughly 750ft2 of these materials in this portion of the building. Vinyl tiles and black mastic <br /> in the third floor gym spaces and offices were asbestos free. <br /> The boiler wrap and some pipe elbows in the mechanical room for the small pool were <br /> found to contain asbestos. This material is in a room directly to the west of the pool and <br /> north of the 1920's building mechanical room. No other TSI sampled from the 1960's and <br /> 1980's portion of the building contained asbestos. <br /> The small pool room had an asbestos containing fireproofing on the ceiling. Roughly <br /> 3,600ft2 of this material were present. The large gym had a fireproofing material in place <br /> that was asbestos free. <br /> Large quantities of asbestos containing material are present in the 1920's portion of <br /> the structure. <br /> Vinyl tiles and black mastic found throughout the 1920's portion of the building contained <br /> asbestos. The 4th and 5th floor contained a total of roughly 10,000ft2 of these materials. A <br /> further 2,500ft2 was found on the 3rd floor. These materials were also found almost <br /> everywhere on the 2nd floor for a total of roughly 10,000ft2. There were an additional <br /> roughly 5,000ft2 of this material present in the basement portion. Total VCT and mastic <br /> ' was roughly 27,000ft2. <br /> Additionally, a black or dark red brittle underlayment was in place below these tiles on the <br /> 2nd floor of the building. This material also contained asbestos and should be assumed to <br /> be in place below the full 10,000ft2 of VCT and mastic on this floor. <br /> A large quantity of asbestos containing TSI were found in this portion of the building. This <br /> included gaskets, elbows, corrugated wrap and paper on both the boilers and ducting in <br /> the mechanical room. This material was in damaged condition and had been disturbed in <br /> 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.