Laserfiche WebLink
.-I <br />Ah <br />Building Permit - .. <br />2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 <br />Project Title: Cadence Aerospace Exterior wall T.Z. <br />Date 02/19/2020 <br />Applicability <br />Code <br />Location in <br />Building <br />(yes,no,na) <br />Section <br />Component <br />Compliance information required in permit documents <br />Documents <br />Department Notes <br />C103.2 <br />Indicate rated U-factor (swinging) or R-value (non -swinging - roll-up/sliding) <br />na <br />C402.4.4 <br />Opaque doors <br />on wall sections or in door schedules - applies to doors with less than 50% <br />glazed area <br />Floor over outdoor or <br />Indicate R-value(s) of cavity/continuous insulation on floor sections; <br />Indicate framing material on floor sections; <br />na <br />C402.2.5 <br />unconditioned space <br />insulation <br />Indicate material density category and weight of qualifying mass floors <br />Indicate R-value of continuous insulation on wall section or foundation <br />detail; <br />na <br />C402.2.6 <br />Slab -on -grade floor <br />Indicate insulation extends down vertically and/or horizontally the required <br />C303.2.1 <br />insulation <br />distance from top of slab; <br />Indicate method of protection of exposed exterior slab edge insulation <br />Indicate R-value of continuous insulation on wall section or foundation <br />Radiantly heated slab <br />detail; <br />na <br />C402.2.6 <br />on -grade floor <br />Indicate insulation extends down vertically from top of slab and then <br />C303.2.1 <br />insulation <br />horizontally under the entire slab; <br />Indicate method of protection of exposed exterior slab edge insulation <br />Radiant heating <br />Indicate insulation R-value behind radiant panels, U-bend/headers and <br />na <br />C402.2.8 <br />system insulation <br />bottom surface of radiantly heated floors (other than radiantly heated slab - <br />on -grade) <br />C402.4.1 <br />Vertical fenestration <br />Provide calculation for total vertical fenestration area as a percentage of <br />na <br />C502.2.1 <br />gross above grade wall area (WWR) for new construction, additions and <br />C503.3.2 <br />maximum area <br />alterations In ENV -SUM <br />Provide calculations showing that the percentage of overall conditioned <br />floor area within daylight zones is equal to or greater than 50% in 1 & 2 <br />story builidngs: OR <br />Provide calculations showing that the percentage of overall net floor area <br />Increased <br />within daylight zones is equal to or greater than 25% in buildings 3 stories or <br />C402.4.1.1 <br />prescriptive <br />more; include the gross floor area and list of spaces omitted for the net floor <br />C405.2.4.1 <br />maximum vertical <br />na <br />C502.2.1 <br />fenestration area with <br />area; <br />Note in envelope plans that all lighting fixtures located within daylight zones <br />C503.3.2 <br />daylight zones and <br />controls <br />shall be provided with daylight responsive controls per WSEC Section <br />C405.2.4.1; indicate method of control in lighting fixture schedules <br />Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br />SHGC <br />Indicate high performance U-factors and SHGC values in fenestration <br />C402.4.1.3 <br />prescriptive <br />schedules; <br />na <br />C502.2.1 <br />maximum vertical <br />fenestration area with <br />If applicable, provide area -weighted U-factor calculation(s) used for multiple <br />C503.3.2 <br />high-performance <br />fenestration elements within the same fenestration category per Table <br />C402.3 <br />Increased <br />C402.4.1.4 <br />prescriptive <br />maximum vertical <br />Indicate that for eligibility, all occupied, conditioned spaces will be served by <br />na <br />C403.6 <br />fenestration area with <br />a dedicated outside air system (DOAS) that delivers ventilation air without <br />DOAS mechanical <br />requiring operation of the heating/cooling system per Section C403.6 <br />systems <br />Wall/vertical <br />Indicate if component performance with target area adjustment will be used <br />na <br />C402.1.5 <br />fenestration target <br />to account for vertical fenestration area in excess of the prescriptive <br />area adjustment <br />maximum allowed <br />na <br />C402.4.1 <br />C502.2.2 <br />Skylight maximum <br />Provide calculation for total skylight area as a percentage of gross roof area <br />C503.3.3 <br />area <br />(SRR) for new construction, additions and alterations in ENV -SUM <br />na <br />C402.1.5.2 <br />Roof/skylight target <br />Indicate if component performance with target area adjustment will be used <br />area adjustment <br />to account for skylight area in excess of the prescriptive maximum allowed <br />Indicate U-factors, SHGC and VT values in fenestration schedules; <br />U-factors, SHGC and <br />If applicable, provide area -weighted U-factor calculation(s) used for multiple <br />na <br />C402.4.3 <br />VT for all fenestration <br />fenestration elements within the same fenestration category per Table <br />C303.1.3 <br />assemblies <br />C402.3 <br />Indicate if values are NFRC or default; if default then specify frame type, <br />glazing layers, gap width, low-e coatings, gas -fill <br />Permanent shading <br />For windows with overhangs or permanent projection shading devices, <br />na <br />C402.4.3 <br />devices <br />provide projection factor calculations (Equation C4-6) and associated <br />minimum SHGC for north and non -north orientations <br />