Laserfiche WebLink
P-I <br />r <br />Building '- r• <br />2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 <br />Project Title: Cadence Aerospace Exterior Wall T.I. Date 02/19/2020 <br />The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy <br />Code, Commercial Provisions. <br />Applicability <br />Code <br />Location in <br />Building <br />(yes,no,na) <br />Section <br />Component <br />Compliance information required in permit documents <br />Documents <br />Department Notes <br />SCOPE <br />Low energy spaces are identified on plans; include project information, and <br />na <br />C402.1.1 <br />Low energy spaces <br />calculations if applicable, that demonstrate spaces are eligible for envelope <br />provisions exemption <br />Semi -heated spaces are identified on plans, include calculations that <br />na <br />C402.1.1.1 <br />Semi -heated spaces <br />demonstrate spaces are eligible for wall insulation exemption <br />Provide building area, average wall and roof U-factor, and installed <br />na <br />C402.1.2 <br />Equipment Buildings <br />equipment information that demonstrates equipment building is eligible for <br />envelope provision exemption <br />na <br />C410.2 <br />Walk-in and <br />warehouse cooler <br />Cooler and freezer spaces are identified on plans; C410 envelope <br />and freezer spaces <br />compliance forms provided (pending) <br />na <br />C101.4.1 <br />Mixed occupancy <br />Spaces with different occupancy requirements are identified on plans <br />Existing unconditioned spaces changing to semi -heated or conditioned <br />na <br />C503.2 <br />Change of space <br />space, and existing semi -heated spaces changing to conditioned space, are <br />conditioning <br />identified on plans. Include calculations that demonstrate baseline and final <br />level of conditioning. <br />Existing F, S and U-occupancy spaces undergoing a change in occupancy <br />are indicated on plans; include calculations that demonstrate upgrade <br />complies with the current WSEC. <br />Pre-2002 Group R spaces undergoing a change to a commercial <br />Change of <br />na <br />C505.1 <br />occupancy are indicated on plans; include calculations that demonstrate <br />occupancy <br />upgrade complies with the current WSEC. <br />Non -Group R occupancy spaces undergoing a change to Group R are <br />indicated on plans; include calculations that demonstrate upgrade complies <br />with the current WSEC. <br />ENVELOPE PROVISIONS <br />Indicate envelope insulation compliance path and provide applicable forms; <br />C103.2 <br />Compliance <br />ENV -PRESCRIPTIVE or ENV-UA / ENV-SHGC for component performance <br />yes <br />C103.6.3 <br />documentation <br />If complying via total buidling performance, provide a list of all proposed <br />envelope component types, areas and U-values <br />C303.1.1 <br />Insulation <br />Indicate identification mark shall be applied to all insulation materials and <br />yes <br />C303.1.2 <br />identification <br />insulation installed such that the mark is readily observable during <br />inspection <br />C303.1.3 <br />Fenestration product <br />Fenestration products shall be labeled with rated U-factor, SHGC, VT, and <br />na <br />C402.4.3 <br />rating <br />leakage rating <br />Indicate installation methods, thicknesses, densities and clearances to <br />C303.1.1 <br />General insulation <br />achieve the intended R-value of all insulation materials; <br />yes <br />C402.2.1 <br />installation <br />Where two or more layers of rigid insulation will be used, indicate that edge <br />joints between layers are staggered <br />Sheet A2 <br />Indicate R-value(s) of cavity/continuous insulation on roof sections; <br />Indicate framing materials on roof sections; <br />Indicate method of framing for ceilings below vented attics and vaulted <br />ceilings per A102.2 (std, adv); <br />Provide area weighted average U-factor calculation for insulation whose <br />C103.2 <br />Roof assembly <br />na <br />C402.2.2 <br />insulation <br />thickness varies by 1 inch or less; <br />Indicate effective U-factors of tapered insulation entirely above deck per <br />Al02.2.6; include roof configuration and slope, maximum R-value at peak <br />and minimum R-value at low point for all roof surfaces <br />Indicate R-values for thermal spacers and each insulation layer, and liner <br />system (LS) method for metal building roofs <br />na <br />C402.2.2 <br />Skylight curb <br />Indicate curb insulation R-value on roof section if not included in skylight <br />insulation <br />NFRC rating <br />Indicate R-value(s) of cavity/continuous insulation on wall sections; <br />Indicate framing materials on wall sections; <br />Indicate method of framing for wood const per A103.2 (std, int, adv); <br />C103.2 <br />Indicate material density category, wall weight and heat capacity for <br />na <br />C402.2.3 <br />Above/below grade <br />qualifying mass walls; <br />C402.2.4 <br />wall insulation <br />For qualifying ASTM C90 masonry walls, indicate loose -fill core insulation <br />C303.2.1 <br />material and percentage of cores filled including grouted cores, bond <br />beams, vertical fills, headers and any other grouted cores; <br />Indicate method of protection of exposed exterior basement/crawlspace wall <br />insulation <br />