My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY CADENCE AEROSPACE 2024-05-03
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
CADENCE AEROSPACE
>
2300 MERRILL CREEK PKY CADENCE AEROSPACE 2024-05-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2024 11:02:46 AM
Creation date
2/15/2022 9:29:16 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
CADENCE AEROSPACE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 <br />Project Info <br />Project Title: Cadence Aerospace Exterior Wall T.I. <br />Date 02/19/2020 <br />Compliance forms <br />do not require a <br />password to use. <br />Applicant Information. Provide contact information for individual who can <br />respond to inquiries about compliance form information provided. <br />For Building Department Use <br />Company Name: LZL Construction, Inc. <br />Instructional and <br />calculating cells are <br />Company Address: 10604 E. Riverside Drive <br />write protected. <br />Applicant Name: Jeff Price <br />Applicant Phone: 425-485-3877 <br />Applicant Email: jeff@lzlconstruction.com <br />Project Description <br />T New Building ❑ Addition 21 Alteration <br />Occupancy Type <br />0 All Commercial O Group R - All R1 and R2, R3, R4 over 3 stories O <br />Selection required to enable forms. <br />Envelope Compliance Path <br />Q Prescriptive O Component Performance <br />Selection required to enable forms. <br />Component Performance <br />Calculation Type <br />O Standard O Change of Occupancy/Conditioning O <br />❑ Additional Efficiency Package Option - C406.8 Enhanced Envelope <br />Selection required to enable ENV-UA <br />and ENV-SHGC forms. <br />To comply, demonstrate building thermal envelope performance is 15% lower than the Target UA. <br />❑ Air barrier testing per Section C402.5.1.2 Air barrier testing not required <br />included in project scope <br />Air Barrier Testing <br />❑ Additional Efficiency Package Option - C406.9 Reduced Air Infiltration <br />To comply, demonstrate that measured air leakage of building envelope does not exceed 0.25 <br />cfm/ft2 (air barrier surface area) under test pressure of 0.3 inch w.g. <br />Vertical Fenestration and <br />Total Vertical Gross Exterior <br />Skylight Area Calculation <br />Prescriptive Path - Enter values for <br />Fenestration Above Grade % Vertical <br />(rough opening) divided by Wall Area times 100 equals Fenestration <br />0.0 — 0.0 X 100 <br />vertical fenestration, skylights, gross walls <br />and roof on this ENV -SUM worksheet. <br />Gross Exterior <br />Total Skylight divided by Roof Area times 100 equals % Skylight <br />Component Performance - Enter values <br />in ENV-UA and/orENV-UA-GROUP-R <br />worksheet. These values auto -fill from <br />0.0 — 0.0 X 100 -(5 [l <br />qS <br />ENV-UA and are write protected on ENV- <br />Vertical <br />Fenestration <br />Fenestration Area Compliance <br />Area <br />Skylight Area <br />Vertical Fenestration <br />O High performance fenestration U-factors and SHGC per C402.4.1.3 <br />Alternates <br />Q Dedicated outdoor air system per C402.4.1.4 and C403.6 <br />Show locations of qualifying daylight zone <br />areas and ft2 on project plans. <br />O In buildings >_ 3 stories, 25% or more of NET floor area is in daylight zones per <br />Q In buildings < 3 stories, 50% or more of CONDITIONED floor area is within daylight zones per <br />For Daylight Zone Area Calculations - <br />a) Sidelight areas include primary + <br />C402.4.1.1 <br />Daylight Zone Calculations <br />secondary daylght zone areas. <br />b) Include overlapping toplight and <br />Sidelight daylight zone areas under <br />Daylight Zone Fenestration Alternate <br />Not Selected. No Calculations Required <br />Sidelight Daylight <br />Zone Area <br />Toplight Daylight <br />Zone Area <br />Percent Daylight <br />Zone Area <br />Toplight. <br />c) Refer to Chapter 2 for net floor area <br />Spaces in Single Story List all enclosed spaces that exceed 2,500 ft2, have ceiling height greater than 15 ft, and are space <br />Building Requiring Skylights types required to comply with this provision. <br />Code requires a minimum of 50% of the floor Space Area (ft) DLZ Area (ft2) SRR or Aperature Exception <br />area to be within a skylight daylight zone for <br />snecific soace tvoes. Refer to C402.4.2 for <br />ZA <br />
The URL can be used to link to this page
Your browser does not support the video tag.