My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY CADENCE AEROSPACE 2024-05-03
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
CADENCE AEROSPACE
>
2300 MERRILL CREEK PKY CADENCE AEROSPACE 2024-05-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2024 11:02:46 AM
Creation date
2/15/2022 9:29:16 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
CADENCE AEROSPACE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 <br />Minimum Requirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration. Refer <br />for Prescriptive Compliance to Tables C402.1.3, C402.1.4 and C402.4 in the 2015 WSEC for important footnotes that apply to <br />these tables. Refer to Section C402 for all applicable requirements that apply for each envelope element <br />type and applicable exceptions. Refer to Section C410 for all applicable information for refrigerated <br />spaces. <br />Prescriptive Path <br />Table C402.1.3 Notes I,7 <br />Insulation Min#mum R-Value <br />Table C402.1.4 Notes 1,2 <br />Assembly Maximum U-factor <br />Occu ancv Grou <br />All Other <br />Group R <br />All Other Group R <br />Opaque Elements <br />Roofs <br />Insulation Entirely above Deck <br />R-38 c.i. <br />R-38 c.i. <br />U-0.027 <br />U-0.027 <br />Metal Building with thermalspacer block Note 3 <br />R-25 + R-1 I Ls <br />R-25 + R-11 Ls <br />U-0.031 <br />U-0.031 <br />Attic and Other <br />R-49 <br />R-49 <br />U-0.021 <br />U-0.021 <br />Joist or single rafter <br />R-49 <br />R-49 <br />U-0.027 <br />U-0.027 <br />Walls, Above grade <br />Mass <br />R-9.5 c.i. Note 6 <br />R-13.3 c.i. <br />U-0.104 Note 6 <br />U-0.078 <br />Mass transfer deck slab edge <br />No R-Value for pre <br />criptive compliance <br />U-0.200 <br />U-0.200 <br />tal But in <br />- <br />R-19 c.i. <br />U-0.052 <br />U-0.052 <br />Steel Framed <br />R-13+R-10c.i. <br />R-19+R-8.56. <br />U-0.055 <br />U-0.055 <br />Wood Fra-me-d and Other <br />- w Int. ra <br />R-21 w/ int. frame <br />U-0.054 <br />U-0.054 <br />Below Grade Wall Note 4 <br />Same as above grade <br />Same as above grade <br />Floors <br />Mass <br />R-30 c.i. <br />R-30 c.i. <br />U-0.031 <br />U-0.031 <br />Steel Joist <br />R-38 + R-10 c.i. <br />R-38 + R-10 c.i. <br />U-0.029 <br />U-0.029 <br />Wood Framed and Other <br />R-30 <br />R-30 <br />U-0.029 <br />U-0.029 <br />Slab -On -Grade Floors <br />Unheated <br />R-10 for 24 in. (from top of slab) <br />F-0.54 <br />F-0.54 <br />Heated Note 5 <br />R-10 perimeter & under entire slab <br />F-0.55 <br />F-0.55 <br />Opaque Doors <br />Swinging <br />No R-Value for prescriptive compliance <br />U-0.37 <br />U-0.37 <br />Nonswin in(Roll-up or sliding) <br />R-4.75 I R-4.75 <br />U-0.34 <br />U-0.34 <br />Table C402.4 - 0-30 % of wall area, or <br />30%-40% per Section C402.3.1.1 DLZ <br />or Section C402.3.1.4 DOAS <br />Section C402.3.1.3 High Performance <br />o <br />Fenestration Option - 0-40/ of well area <br />Fenestration <br />Assembly Maximum ti-factor Notes 1,2 <br />Vertical Fenestration <br />Nonmetal framing <br />U-0.30 <br />U-0.30 <br />U-0.28 <br />U-0.28 <br />Metal framing (fixed) <br />U-0.38 <br />U-0.38 <br />U-0.34 <br />U-0.34 <br />Metal framing (operable) <br />U-0.40 <br />U-0.40 <br />U-0.36 <br />U-0.36 <br />Entrance doors <br />U-0.60 <br />U-0.60 <br />U-0.60 <br />U-0.60 <br />Skylights <br />Skylights <br />U-0.50 U-0.50 U-0.50 U-0.50 <br />Fenestration <br />Assembly Maximum SHGC Factor <br />Vertical Fenestration <br />PF<0.2: north - SHGC=0.53; <br />all other SHGC=0.4 <br />0.25 PF < 0.5: north - SHGC-0.58; <br />all other - SHGC-0.48 <br />PF >_ 0.5: all orientations - SHGC-0.64 <br />PF<0.2: north - SHGC=0.46; <br />all other SHGC=0.35 <br />0.25 PF < 0.5: north - SHGC-0.51; <br />all other - SHGC-0.42 <br />PF >_ 0.5: all orientations - SHGC-0.56 <br />Skylights <br />SHGC-0.35 <br />SHGC-0.35 <br />(`410.2 Refrigerated Spaces Insulation <br />Insulation Minimum R-Value <br />Assembly Maximum U-factor <br />Freezers - Walk-in and Warehouse <br />Roof / Ceiling <br />R-32 <br />U-0.030 <br />Wall <br />R-32 <br />U-0.030 <br />Door <br />R-32 <br />U-0.030 <br />Door - transparent reach -in <br />triple -pane, heat -reflective treated or gas <br />Floor <br />R-28 <br />U-0.035 <br />Coolers - Walk-in and Warehouse <br />Roof / Ceiling <br />R-25 <br />U-0.039 <br />Wall <br />R-25 <br />U-0.039 <br />Door <br />R-25 <br />U-0.039 <br />Door - transparent reach -in <br />double -pane, heat -reflective treated & gas <br />fill, or comply with freezer door req. <br />Floor <br />No Requirement <br />
The URL can be used to link to this page
Your browser does not support the video tag.