My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2621 ROCKEFELLER AVE 2019 Plans 2022-12-01
>
Address Records
>
ROCKEFELLER AVE
>
2621
>
Plans
>
2621 ROCKEFELLER AVE 2019 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:07:22 AM
Creation date
2/17/2022 2:56:19 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2621
Permit
B1912-029
Year
2019
Notes
NEW ROCKEFELLER SQUARE MULTI FAMILY (30) UNITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mu <br />n "l l 1-11 <br />2NU D FLOOR: (E IfMPT P ROM COMPLYINGWITH AN 1 A,1 17.1 E UI NT ) <br />ARCHITECT TO REVIEW BATHING FIXTURE SUBMITTAL <br />PRIOR TO FLAMING TO CONFIRM COMPLIANCE. <br />SEE SHEET AG.2 INTERIOR ELEVATIONS FOR LOCATION <br />OF GRAB BARS AND BACKING, ALSO NOTE LOCATION <br />OF WATER CLOSETS AND TUB CONTROLS <br />I�J�11•ir'��l�� <br />PROVIDE BACKING FOR GRAB BARS IN ALL BATHROOM UNITS AS SHOWN ON SHEET AG. I t- AG.2. DEFERRED M O SUBMITTAL { <br />ALL TOILETS SHALL BE CENTERED EXACTLY 18 INCHES FROM FACE OF FINISHED SIDE WALL. j <br />PROVIDE ACCESSIBLE CONTROLS FOR POWER AND SPEED AT WALL MOUNTED CONTROLS. <br />ENSURE THAT CONTROLS ARE NOT LOWER THAN 15" AND AT TYPE "A" UNITS THAT THE CONTROLS DO NOT REQUIRE TWISTING OR GRIPPING, OPERABLE <br />AIR INLETS, WINDOW TRICKLE VENTS, FRE5H AIR OPENINGS FOR OUTDOOR AIR. MUST BE ACCE551BLE WITH ACCESSIBLE CONTROLS WITHIN REACH RANGE ON TYPE "A" AND TYPE "B" UNITS. PER W5EC <br />403.8.G. 1 <br />FOR TYPE "A" UNITS ALL CONTROLS MUST BE ACCE5515LE (LEVER STYLE OR SIMILAR) WHICH INCLUDES OPERABLE WINDOWS, SINK AND LAVATORY FAUCETS, KITCHEN CABINET DOOR HARDWARE, AND DOOR <br />HARDWARE. <br />FOR TYPE "A" UNITS AND A PORTION OF ALL STORAGE CLOSETS MUST BE ACCESSIBLE, ENSURE THAT A PORTION OF A CLOSET POLE IS MOUNTED NO GREATER THAN SIG INCHES AFF. <br />FOR TYPE "A" UNIT PROVIDE A SINK WITH A DRAIN AT THE BACK OF THE BOWL 50 THAT DRAIN PIPES AND DISPOSAL UNITS ARE OUT OF THE KNEE CLEARANCE SPACE. <br />PROVIDE COUNTER TOP MICROWAVE FOR TYPE "A" UNIT <br />FOR ALL UNITS PROVIDE A PORTION OF TOWEL BARS MOUNT AT 48" AFF. <br />FOR TYPE "A" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL SURFACE IN "L" AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 24" THE ACCE551BLE <br />OUTLET IN THE CORNER IS CALCULATED BY APPLIANCE DEPTH DIMEN51ON PLUS 12 WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT 15 <br />UNINTERRUPTED BY A 5INK OR APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/ANSI A 1 1 7. I -2009 SECTION 309. <br />FOR TYPE "B" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL SURFACE IN "L" AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 25 1 /2" THE <br />ACCE551BLE OUTLET IN THE CORNER 15 CALCULATED BY APPLIANCE DEPTH DIM-FN51ON PLUS 1 2". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF <br />COUNTERTOP THAT 15 UNINTERRUPTED BY A 51NK OR APPLIANCE, ONE RECEPTACLE OUTLET 51-IALL NOT BE REQUIRED TO COMPLY WITH ICC/ANSI A 1 17. 1-2.000 SECTION 309. <br />FOR TYPE "A" UNIT PROVIDE COMBINATION WA51-IER/DRYER. PROVIDE FOR PARALLEL APPROACH. CLEAR FLOOR SPACE SHALL BE CENTERED ON APPLIANCE. <br />OPERABLE PARTS INCLUDING DOORS, LINT SCREEN, DETERGENT AND BLEACH COMPARTMENTS 5HALL BE NO LOWER THAN 15" ABOVE F.F. AND NOT MORE THAN 40 ABOVE F.F. <br />TYPE "A" KITCHEN COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER 15 HIGHEST). <br />TYPE "B" KITCHEN COUNTERTOP 25 1 /2" MAX. DEPTH, 30 MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER 15 HIGHEST). <br />TYPE "A" * "B" BATHROOM COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF 5INK OR COUNTER WHICHEVER 15 HIGHEST): <br />FOR TYPE "B" UNITS A STACKABLE WA5HER/DRYER COMBINATION CAN BE PROVIDED. <br />UNITS ON 2ND AND 3RD FLOOR EXEMPT FROM COMPLYING WTHI ANSI A 1 17.1 REQUIREMENTS. <br />�i <br />U II 1 II <br />(1 I P "B" UNIT) <br />430 fT <br />UNIT 1,290 /fT <br />DECK — 5G 5 /fT <br />UNITS # 108, <br />20-G" <br />I <br />NET NOTES <br />SELF -RIMING STAINLESS STEEL SINK, SINGLE BOWL; SINGLE LEVER <br />FAUCET. ENSURE KNEE CLEARANCE AT 27" AFF IN TYPE "A" UNITS <br />BUILT-IN DISHWASHER, ENERGY STAR <br />® 30" ELECTRIC RANGE WITH MICROWAVE/HOOD FAN ABOVE <br />30" ELECTRIC RANGE WITH HOOD FAN ABOVE <br />REFRIGERATOR SPACE <br />®PLASTIC LAMINATE COUNTERTOP WITH 4" WATERFALL 5ACK5PLA5H <br />AND BULLN05E FRONT EDGE; CABINETS BELOW <br />® LINE OF CABINETS ABOVE <br />® PONY WALL <br />® CARPET STRIP @ CARPET/VINYL TRANSITION <br />FI-01 30X24 WORK AREA @ MAX 34" HEIGHT - OPEN BELOW <br />M 1.28 GAL. MAXIMUM FLUSH WATER CLOSET; POUND BOWL; PROVIDE IN SPACE <br />MINIMUM 30 WIDE IN ACCE55113LF_ UNITS, MINIMUM 33" WIDE IN TYPE "B" UNITS <br />GRAB BARS FOR WATER CLOSET <br />[F31 SURFACE MOUNTED TOILET PAPER DOPEN5ER, MOUNT BOTTOM MIN 15" AFF � TOP MAX 33" AFF <br />14 LAVATORY; SINGLE LEVER 1.5 GPM FAUCET AND CABINET <br />F1 51 SURFACE MOUNTED MIRROR WITH J-Ci_IP5 TO MATCH VANITY <br />DA30" TOWEL BAR; PROVIDE 50LID BACKING IN WALL; MOUNT CENTER OF BAR <br />MAX. 4'-G" AFF. IN ALL UNITS MOUNT A PORTION OF TOWEL BARS @ 48" AFF <br />177 FIBERGLASS TUB WITH PLASTIC LAMINATE SURROUND: TOP OF 5URROUND <br />MINIMUM 72" ABOVE FLOOR; PROVIDE WITH BATH CURTAIN ROD <br />t� SHOWER HEAD 1.75 GPM; MOUNT 4" ABOVE TOP OF 5URROUND <br />i PURR WALL TO TUB ENCLOSURE; VERIFY DIMEN51ON5 <br />5' SHOWER ((NSIDE CLEAR 3G" X GO" MIN.) <br />F2--11 ADA 5' ROLL -IN SHOWER WITH SEAT <br />SHOWER SPRAY UNIT 1.75 GPM, WITH A HOSE AT LEAST GO" LONG, THAT CAN BE USED <br />AS A FIXED5HOWER HEAD OR AS A HAND HELD SHOWER <br />�o GRAB BARS FOR ROLL -IN SHOWER <br />�-4 STACKED WA5HER/DRYER W/ VENT TO THE EXTERIOR (80 CFM), ENERGY STAR <br />9 COMBINATION WA5H-FR/DRYER W/ VENT TO EXTERIOR (80 CFM), ENERGY STAR <br />1 - 1 2" WIRE SHELF � POLE <br />5 - 1 2" WIRE 5HELVE5 <br />1 O'-2� I 10'-34' <br />mom <br />NOTE: ALL DOORS TO BE 3'-0" X 0-8" <br />UNIT ENTRY DOORS TO BE 20 MIN RATED <br />AND BE EQUIPPED WITH VIEWER * DEAD BOLT LOCK <br />ALL HARDWARE TO HAVE LEVER L OCK5ET5 <br />PUBLIC SITE OF THE UNIT PRIMARY ENTRANCE PER AN51 SECTION 1005.5. 1 <br />A MEANS FOR VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE UNIT <br />ENTRY DOOR SHALL BE PROVIDED PER ANSI SECTION 1005.5.2 <br />NOTE: ALL BATHS * KITCHENS TO BE MECHANICALLY VENTED TO EXTERIOR <br />NOTE: PROVIDE REMOVABLE CABINET IN ALL TYPE "A" BATHROOM AND SUPPORT AT OPEN END, <br />PROVIDE FINISH FLOOR UNDER REMOVABLE CABINET <br />ALL UNITS NOT DESIGNATED AS TYPE "A" SHALL BE TYPE "B" UNITS <br />ALL TYPE "A" UNITS SHALL MEET THE REQUIREMENTS OF ICC/ANSI A 1 1 7. 1-2009 <br />OUTLETS TO BE NO LOWER THAN 15" HIGH MEASURED FROM CENTERLINE OF LOWEST <br />OUTLET TO THE FINISH FLOOR. <br />COUNTER TOP OUTLETS TO BE MAXIMUM 44" HIGH MEASURED FROM FINISHED FLOOR TO <br />HIGHEST OUTLET. <br />SWITCHES AND THERMOSTATS MAXIMUM 46" TO THE HIGHEST CONTROLS. <br />KITCHEN CORNER OUTLETS MUST BE A MINIMUM 30 FROM INSIDE CORNER OF WALL <br />SURFACE IN L-SHAPE AND U-SHAPE KITCHENS. <br />NOTE: ALL WINDOWS TO BE DOUBLE GLAZED VINYL FRAME W/ACCESSIBLE CONTROLS <br />WINDOWS W/.28 "U FACTOR � .40 5HGC <br />LN a. <br />VERI fY WALL TYPE5 AS PER. RA 1. 15t1ff-T R <br />STANDARD WALL (I HR)(5EE 5HT RA I . I #3) ® WINDOW INDICATOR <br />CORRIDOR WALL (5EE 5HT RA1 . 1 #4) <br />3z= DOOR INDICATOR <br />PLUMBING CORRIDOR WALL (5EE 5HT RA I . 1 #4) � <br />UNIT PARTITION WALL (5EE 5HT RA 1. I #5) <br />€ .� 50FFIT5 FOR. DUCT5 <br />EXTERIOR WALL (5EE 5HT RA 1. 1 # I) 9 DETAIL INDICATOR (5EE D I. 5HT5) <br />2 HR WALL - GENERIC (SEE 5HT RA 1. 1 #G) 3 INTERIOR ELEVATIONS (5EE 5HT AG. 1) <br />6.1 <br />2 HR WALL - (5TC 50) (5EE 5HT RA 1 .2 #20) k <br />2 HR EXTERIOR WALL (5EE 5HT RA 1.2 # 19) $� 5MOKE DETECTOR5 <br />I HR 2 51DED EXTERIOR WALL ON DECK CARBON MONOXIDE DETECTOR <br />L <br />m <br />U <br />tu <br />Lu <br />Lu <br />Lu <br />ILLA <br />Q) <br />�3 QLU <br />Q <br />c <br />0 <br />STATES LICENSED; <br />WASHINGTON <br />ARIZONA <br />IDAHO <br />NEW MEXICO <br />MONTANA <br />WYOMING <br />CALIFORNIA <br />COLORADO <br />NEVADA <br />NEDRASKA <br />UTAH <br />MISSOURI <br />ILLINOIS <br />INDIANA <br />mw <br />STUDIO "A", <br />" 99 III " d1 SHEET <br />TYPICAL UNITS <br />SCALE 1 /4" = 1 '-011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.