milt <br />t~ <br />2' 10'- 112GI-0ll <br />20-0" <br />I BEDROOM 91131 li <br />ARCHITECT TO REVIEW BATHING FIXTURE SUBMITTAL <br />PRIOR TO FRAMING TO CONFIRM COMPLIANCE. <br />l <br />1 Ln ► Ln <br />1 I <br />FD mist mlv- <br />FDJ N <br />� �I - <br />Ln Ln m� <br />! ) I <br />I <br />© [D <br />! � m <br />DO <br />SEE SHEET AG.2 INTERIOR ELEVATIONS FOR LOCATION <br />OF GRAB BARS AND BACKING. ALSO NOTE LOCATION <br />OF WATER, CLOSETS AND TUB CONTROLS <br />71-1 <br />UNIT # 107 <br />PROVIDE BACKING FOR GRAB BARS IN ALL BATHROOM UNITS AS SHOWN ON SHEET AG. I * AG.2. \ <br />ALL TOILETS SHALL BE CENTERED EXACTLY 18 INCHES FROM FACE OF FINISHED SIDE WALL. <br />2'-10" 4'-0" <br />23'-32' <br />31-3" 1 '-1 I " ,_ 3'-102, <br />4'-3" 3'-2" <br />I1 <br />5TG. <br />t <br />BECROW <br />0A <br />^�23u -(1 \2-��u 2-sillz 2 iu <br />5-1 12 <br />/ O <br />❑ 1 �'J / / <br />1 ® _ �4 <br />I REF <br />I -ju DINE <br />30x48 <br />CLEAR I A�. 35 <br />SPACE14 <br />_ <br />40 -� I �/LffA>g 112 ❑ <br />VV PACE `✓ III DWI D I <br />?03 I_ _ _ __j IOA6.1 ---- I <br />W RK _ <br />SEA I I r —3bx48 /'� CLEAR <br />—KIT — CLEAR SPACE iy <br />TO I <br />I O = 3 i SPACE/^�=SI� <br />— - . f ) 0 2 AR�N( <br />® �W I 5PA E 20 6.222 / <br />1 G❑ I I 27 ' <br />I a MIN <br />n1L ! -� <br />�1 <br />8' GI" 5' 25u 9'-G& <br />8 � 4 <br />23'-32" <br />j, <br />PROVIDE ACCESSIBLE CONTROLS FOR POWER AND SPEED AT WALL MOUNTED CONTROLS. <br />ENSURE THAT CONTROLS ARE NOT LOWER THAN 15" AND AT TYPE "A" UNITS THAT THE CONTROLS DO NOT REQUIRE TWISTING OR GRIPPING. OPERABLE <br />AIR INLETS, WINDOW TRICKLE VENTS, FRESH AIR OPENINGS FOR OUTDOOR AIR, MUST BE ACCESSIBLE WITH ACCESSIBLE CONTROLS WITHIN REACH RANGE ON TYPE "A" AND TYPE "B" UNITS. PER WSEC <br />403.8.G. I <br />FOR TYPE "A" UNITS ALL CONTROLS MUST BE ACCESSIBLE (LEVER STYLE OR SIMILAR) WHICH INCLUDES OPERABLE WINDOWS, SINK AND LAVATORY FAUCETS, KITCHEN CABINET DOOR, HARDWARE, AND DOOR <br />HARDWARE. <br />FOR TYPE "A" UNITS AND A PORTION OF ALL STORAGE CLOSETS MUST BE ACCESSIBLE. ENSURE THAT A PORTION OF A CLOSET POLE 15 MOUNTED NO GREATER THAN 4G INCHES AFF. <br />FOR TYPE "A" UNIT PROVIDE A SINK WITH A DRAIN AT THE BACK OF THE BOWL 50 THAT DRAIN PIPES AND DISPOSAL UNITS ARE OUT OF THE KNEE CLEARANCE SPACE. <br />PROVIDE COUNTER TOP MICROWAVE FOR TYPE "A" UNITS <br />FOR ALL UNITS PROVIDE A PORTION OF TOWEL BARS MOUNT AT 48" AFF. <br />FOR TYPE "A' UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL SURFACE IN "L" AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 24" THE ACCESSIBLE <br />OUTLET IN THE CORNER 15 CALCULATED BY APPLIANCE DEPTH DIMEN51ON PLUS 1 2". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT IS <br />UNINTERRUPTED BY A SINK OR APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/AN51 A 1 17. 1-2009 SECTION 309. <br />FOR TYPE "B" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL SURFACE IN "U'AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 25 1 /2" THE <br />ACCESSIBLE OUTLET IN THE CORNER 15 CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF <br />COUNTERTOP THAT IS UNINTERRUPTED BY A SINK OR APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH (CC/ANSI A 117. 1-2009 SECTION 309, <br />FOR TYPE "A" UNIT PROVIDE COMBINATION WASHER/DRYER. PROVIDE FOR PARALLEL APPROACH. CLEAR FLOOR SPACE SHALL BE CENTERED ON APPLIANCE. <br />OPERABLE PARTS INCLUDING DOORS, LINT SCREEN, DETERGENT AND BLEACH COMPARTMENTS SHALL BE NO LOWER THAN 15" ABOVE F.F. AND NOT MORE THAN 40 ABOVE F.F. <br />TYPE "A" KITCHEN COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER 15 HIGHEST). <br />TYPE "B" KITCHEN COUNTERTOP 25 1 /2" MAX. DEPTH, 30 MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER IS HIGHEST). <br />TYPE "All � "BII BATHROOM COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER IS HIGHEST), <br />FOR TYPE "B" UNITS A STACKABLE WASHER/DRYER COMBINATION CAN BE PROVIDED. <br />UNITS ON 2ND AND 3RD FLOOR EXEMPT FROM COMPLYING WTHI AN51 A 1 1 7. 1 REQUIREMENTS. <br />I BEDROOM "All <br />i <br />(TYPE "A" UNIT) <br />58 1 ET <br />I UNIT <br />DECK - I 1 /FT <br />UNIT# I 10 <br />hT NOTES <br />SELF -RIMING STAINLESS STEEL SINK; SINGLE BOWL; SINGLE LEVER <br />FAUCET. ENSURE KNEE CLEARANCE AT 27" AFF IN TYPE "A" UNITS <br />® BUILT-IN DISHWASHER, ENERGY STAR <br />30" ELECTRIC RANGE WITH MICROWAVE/HOOD FAN ABOVE <br />® 30" ELECTRIC RANGE WITH HOOD FAN ABOVE <br />® REFRIGERATOR SPACE <br />PLASTIC LAMINATE COUNTERTOP WITH 4" WATERFALL BACK5PLA5H <br />AND BULLN05E FRONT EDGE; CABINETS BELOW <br />® LINE OF CABINETS ABOVE <br />7 PONY WALL <br />® CARPET STRIP @CARPET/VINYL TRANSITION <br />I O 30X24 WORK AREA @ MAX 34" HEIGHT - OPEN BELOW <br />1 I 1.26 GAL. MAXIMUM FLUSH WATER CLOSET; ROUND BOWL; PROVIDE IN SPACE <br />MINIMUM 30 WIDE IN ACCE5515LE UNITS, MINIMUM 33" WIDE IN TYPE "B" UNITS <br />T2 GRAB BARS FOR WATER CLOSET <br />1 SURFACE MOUNTED TOILET PAPER DISPENSER, MOUNT BOTTOM MIN 15" AFF �- TOP MAX 33" AFF <br />I 4LAVATORY; SINGLE LEVER 1.5 GPM FAUCET AND CABINET <br />SURFACE MOUNTED MIRROR WITH J-CUPS TO MATCH VANITY <br />I 30" TOWEL BAR; PROVIDE SOLID BACKING IN WALL; MOUNT CENTER OF BAP <br />MAX. 4'-G" AFF. IN ALL UNITS MOUNT A PORTION OF TOWEL BARS @ 48" AFF <br />1 % FIBERGLASS TUB WITH PLASTIC LAMINATE SURROUND: TOP OF SURROUND <br />MINIMUM 72" ABOVE FLOOR; PROVIDE WITH BATH CURTAIN ROD <br />1 8 SHOWER HEAD 1.75 GPM; MOUNT 4" ABOVE TOP OF SURROUND <br />I FURR WAIL TO TUB ENCLOSURE; VERIFY DIMENSIONS <br />5SHOWER (INSIDE CLEAR 30 X GO" MIN.) <br />ADA 5' ROLL -IN SHOWER WITH SEAT <br />SHOWER SPRAY UNIT 1.75 GPM, WITH A HOSE AT LEAST GO" LONG, THAT CAN BE USED <br />AS A PIXEDSHOWER HEAD OR AS A HAND HELD SHOWER <br />GRAB BARS FOR ROLL -IN SHOWER <br />4 STACKED WASHER/DRYER W/ VENT TO THE EXTERIOR (80 CFM), ENERGY STAR <br />5 COMBINATION WA5HER/DRYER W/ VENT TO EXTERIOR (80 CFM), ENERGY STAR <br />27G I 1 2" WIRE SHELF * POLE <br />�P7 5 - 12" WIRE SHELVES <br />n/1i 1-11 <br />NOTE: ALL DOORS TO BE 31-0" X 0-8" <br />UNIT ENTRY DOORS TO BE 20 MIN RATED <br />AND BE EQUIPPED WITH VIEWER * DEAD BOLT LOCK <br />ALL HARDWARE TO HAVE LEVER LOCK5ET5 <br />PUBLIC SITE OF THE UNIT PRIMARY ENTRANCE PER ANSI SECTION 1005.5. 1 <br />A MEANS FOR VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE UNIT <br />ENTRY DOOR SHALL BE PROVIDED PER ANSI SECTION 1005.5.2 <br />NOTE: ALL BATHS * KITCHEN5 TO BE MECHANICALLY VENTED TO EXTERIOR <br />NOTE: PROVIDE REMOVABLE CABINET IN ALL TYPE "A" BATHROOM AND SUPPORT AT OPEN END <br />PROVIDE FINISH FLOOR UNDER REMOVABLE CABINET <br />ALL UNITS NOT DESIGNATED AS TYPE "A" SHALL BE TYPE "B" UNITS <br />ALL TYPE "A" UNITS SHALL MEET THE REQUIREMENTS OF ICC/AN51 Al 17. 1-2009 <br />OUTLETS TO BE NO LOWER THAN 15" HIGH MEASURED FROM CENTERLINE OF LOWEST <br />OUTLET TO THE FINISH FLOOR, <br />COUNTERTOP OUTLETS TO BE MAXIMUM 44" HIGH MEASURED FROM FINISHED FLOOR TO <br />HIGHEST OUTLET. <br />SWITCHES AND THERMOSTATS MAXIMUM 48" TO THE HIGHEST CONTROLS. <br />KITCHEN CORNER OUTLETS MUST BE A MINIMUM 30 FROM INSIDE CORNER OF WALL <br />SURFACE IN L-SHAPE AND U-SHAPE KITCHENS. <br />NOTE: ALL WINDOWS TO BE DOUBLE GLAZED VINYL FRAME W/ACCESSIBLE CONTROLS <br />WINDOWS W/.28 "U" FACTOR. * .40 5HGC <br />LEGEND <br />IT OF- V FE RF <br />VERIFY WALL TYPES AS PER RA 1. 1 SHEET <br />s-. <br />STANDARD WALL (I HR)(5EE 5HT RA 1. 1 #3) <br />- 1, <br />WINDOW INDICATOR <br />CORRIDOR WALL (SEE 5HT RA I . 1 #4) <br />PLUMBING CORRIDOR WALL (SEE SHT RA 1. 1 #4) <br />szG <br />DOOR INDICATOR <br />;� <br />! <br />SOFFITS FOR DUCTS <br />UNIT PARTITION WALL (SEE 5HT RA 1. 1 #5) <br />EXTERIOR. WALL (SEE 5HT RA 1. 1 # 1) <br />5 _ <br />DETAIL INDICATOR (SEE D 1. 5HTS) <br />2 HR WALL - GENERIC (SEE 5HT RA I . I #0) <br />INTERIOR ELEVATIONS (SEE 5HT AG. 1) <br />2 HR WALL - (5TC 50) (SEE 5HT RA 1 .2 #20) <br />4 <br />2 HR EXTERIOR WALL (SEE_ 5HT RA 1.2 # 19) <br />sA <br />SMOKE DETECTORS <br />c® <br />CARBON MONOXIDE DETECTOR <br />I HR 2 51DED EXTERIOR WALL ON DECK <br />TYPICAL UNITS <br />5GAL.E 114" e 1 -011 <br />Ali <br />Lu <br />oz <br />D <br />( ) <br />CZ <br />Lu <br />U— <br />LL 1 <br />1- <br />Lu <br />0 <br />0 <br />STATES LICENSED: <br />WASHINGTON <br />ARIZONA <br />IDAHO <br />NEW MEXICO <br />MONTANA <br />WYOMING <br />CALIFORNIA <br />COLORADO <br />NEVADA <br />NEBRASKA <br />UTAH <br />MISSOURI <br />ILLINOIS <br />INDIANA <br />