2621 ROCKEFELLER AVE 2019 Plans 2022-12-01
>
Address Records
>
ROCKEFELLER AVE
>
2621
>
Plans
>
2621 ROCKEFELLER AVE 2019 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:07:22 AM
Creation date
2/17/2022 2:56:19 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2621
Permit
B1912-029
Year
2019
Notes
NEW ROCKEFELLER SQUARE MULTI FAMILY (30) UNITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARCHITECT TO REVIEW BATHING FIXTURE SUBMITTAL <br />PRIOR TO FRAMING TO CONFIRM COMPLIANCE. <br />SEE SHEET AG.2 INTERIOR ELEVATIONS FOR LOCATION <br />OF GRAB BARS AND BACKING. ALSO NOTE LOCATION <br />OF WATER CLOSETS AND TUB CONTROLS <br />3'-2" 4'-3" L ®2 I '-1 It' 3'-3" 4' 0" 21- 1 O° <br />1 i DECK <br />5TG 7K <br />[:A] ® I O <br />7G <br />BEDROOM � <br />LIVING <br />A <br />4'-5111 3'-1 1 g 51_C!, 21_52' v <br />a{ 3Ox4b <br />✓ CLEAR <br />SPACE <br />261 I 33 6.2 DINE u <br />33 W/ D71 I 36 6.2 W <br />15 <br />11 DW <br />I � � 3Ox4 <br />23 PAC z66. 24 7 1 <br />13 KIT _ <br />1-3-35 —0) A6.I —1N <br />3Ox48 2 6.2 1 -1 � <br />CLEAR i� 130x48 <br />j SPACE SLAGS <br />18 I � +MIN <br />� ( <br />-- - — — <br />N <br />5'-32" <br />PROVIDE BACKING FOR GRAB BARS IN ALL BATHROOM UNITS AS SHOWN ON SHEET AG. I * AG.2. DEFERRED MEC SUBMITTAL <br />ALL TOILETS SHALL BE CENTERED EXACTLY 18 INCHES FROM FACE OF FIN15HED SIDE WALL. <br />PROVIDE ACCESSIBLE CONTROLS FOR POWER AND SPEED AT WALL MOUNTED CONTROLS, <br />ENSURE THAT CONTROLS ARE NOT LOWED, THAN 15" AND AT TYPE "A" UNITS THAT THE CONTROLS DO NOT REQUIRE TWISTING OR GRIPPING. OPERABLE <br />AIR INLETS; WINDOW TRICKLE VENTS, FRESH AIR OPENINGS FOR OUTDOOR AIR. MUST BE ACCESSIBLE WITH ACCESSIBLE CONTROLS WITHIN REACH RANGE ON TYPE "A" AND TYPE "B" UNITS. PER WSEC <br />403.5.6.1 <br />FOR TYPE "A" UNITS ALL CONTROLS MUST BE ACCESSIBLE (LEVER STYLE OR SIMILAR) WHICH INCLUDES OPERABLE WINDOWS, SINK AND LAVATORY FAUCETS, KITCHEN CABINET DOOR HARDWARE, AND DOOR <br />HARDWARE. <br />FOR TYPE "A" UNITS AND A PORTION OF ALL STORAGE CLOSETS MUST BE ACCESSIBLE. ENSURE THAT A PORTION OF A CLOSET POLE 15 MOUNTED NO GREATER THAN 4G INCHES AFF, <br />FOR TYPE "A" UNIT PROVIDE A SINK WITH A DRAIN AT THE BACK OF THE BOWL 50 THAT DRAIN PIPES AND DISPOSAL UNITS ARE OUT OF THE KNEE CLEARANCE SPACE. <br />PROVIDE COUNTER TOP MICROWAVE FOR TYPE "A" UNITS <br />FOR ALL UNITS PROVIDE A PORTION OF TOWEL BARS MOUNT AT 48" AFF. <br />FOR TYPE "A" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 30 FROM INSIDE CORNER OF WALL 5URFACE IN 1!'AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 24" THE ACCESSIBLE <br />OUTLET IN THE CORNER 15 CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2 WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT 15 <br />UNINTERRUPTED BY A SINK OR APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH (CC/AN51 A 1 1 7. I -2009 SECTION 309, <br />FOR TYPE "B" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 36" FROM INSIDE CORNER OF WALL SURFACE IN "L" AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 25 1 /2" THE <br />ACCESSIBLE OUTLET IN THE CORNER IS CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 12". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF <br />COUNTERTOP THAT IS UNINTERRUPTED BY A SINK OR APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/AN51 A 1 1 7. 1-2009 SECTION 309. <br />FOR TYPE "A" UNIT PROVIDE COMBINATION WA5HER/DKYER. PROVIDE FOR PARALLEL APPROACH. CLEAR FLOOR SPACE SHALL BE CENTERED ON APPLIANCE, <br />OPERABLE PARTS INCLUDING DOORS, LINT SCREEN, DETERGENT AND BLEACH COMPARTMENT5 SHALL BE NO LOWER THAN 15" ABOVE F.F. AND NOT MORE THAN 40 ABOVE F.F. <br />TYPE "A" KITCHEN COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF 51NK OR COUNTER WHICHEVER 15 HIGHEST). <br />TYPE "B" KITCHEN COUNTERTOP 25 1/2" MAX. DEPTH, 3G" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER IS HIGHEST). <br />TYPE "A" * "B" BATHROOM COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP Of SINK OR COUNTER WHICHEVER 15 HIGHEST). <br />FOR TYPE "B" UNITS A 5TACKA13LF WA5HER/DRYER COMBINATION CAN BE PROVIDED. <br />UNITS ON 2ND AND 3RD FLOOR EXEMPT FROM COMPLYING WTHI AN51 A 1 1 7. 1 REQUIREMENTS. <br />1 O'-1 ob, <br />5EE f LOOP, PLAN5 fOR WINDW5 TYPE5 ON 2ND D fL5 <br />Ii it <br />SHEET NOTES <br />SELF -RIMING 5TAINLE55 STEEL SINK; SINGLE BOWL; SINGLE LEVER <br />NOTE: ALL DOORS TO 13E 3'-0" X 0--8° <br />D:1 <br />FAUCET. ENSURE KNEE CLEARANCE AT 27" AFF IN TYPE "A" UNITS <br />UNIT ENTRY DOORS TO BE 20 MIN RATED <br />® <br />BUILT-IN DISHWASHER, ENERGY STAR <br />AND BE EQUIPPED WITH VIEWER � DEAD BOLT LOCK <br />ALL HARDWARE TO HAVE LEVER LOCK5ET5 <br />30" ELECTRIC RANGE WITH MICROWAVE/HOOD FAN ABOVE <br />PUBLIC SITE OF THE UNIT PRIMARY ENTRANCE PER ANSI SECTION 1005.5. 1 <br />�� <br />A MEANS FOR VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE UNIT <br />� ' <br />1 <br />30" ELECTRIC RANGE WITH HOOD FAN ABOVE <br />ENTRY DOOR SHALL BE PROVIDED PER AN51 SECTION 1005.5.2 <br />® <br />REFRIGERATOR SPACE <br />NOTE: ALL BATHS � KITCHENS TO BE MECHANICALLY VENTED TO EXTERIOR <br />PLASTIC LAMINATE COUNTERTOP WITH 4" WATERFALL BACK5PLA5H <br />NOTE: PROVIDE REMOVABLE CABINET IN ALL TYPE "A" BAI HROOM AND SUPPORT AT OPEN END, <br />I_ <br />I <br />AND 5ULLN05E FRONT EDGE; CABINETS BELOW <br />PROVIDE FINISH FLOOR UNDER REMOVABLE CABINET <br />® <br />LINE OF CABINETS ABOVE <br />❑ALL <br />PONY WALL <br />UNITS NOT DESIGNATED AS TYPE "A" SHALL BE TYPE "B" UNITS <br />ALL TYPE "A` UNITS SHALL MEET THE REQUIREMENTS OF ICC/ANSI A I 1 7. 1-2009 <br />CARPET STRIP @ CARPET/VINYL TRANSITION <br />OUTLETS TO BE NO LOWER THAN 15" HIGH MEASURED FROM CENTERLINE OF LOWEST <br />I <br />3J9OX24 WORK AREA @ MAX 34" HEIGHT - OPEN BELOW <br />OUTLET TO THE FINISH FLOOR. <br />COUNTER TOP OUTLETS TO BE MAXIMUM 44" HIGH MEASURED FROM FINI5HED FLOOR TO <br />I <br />1.28 GAL. MAXIMUM FLUSH WATER CLOSET; ROUND BOWL; PROVIDE IN SPACE <br />HIGHEST OUTLET. <br />MINIMUM 36" WIDE IN ACCESSIBLE UNITS, MINIMUM 33" WIDE IN TYPE "B" UNITS <br />SWITCHES AND THERMOSTATS MAXIMUM 48" TO THE HIGHEST CONTROLS, <br />I <br />GRAB BARS FOR WATER CLOSET <br />KITCHEN CORNER OUTLETS MUST BE A MINIMUM 30 FROM INSIDE CORNER OF WALL <br />SURFACE IN L-SHAPE AND U-SHAPE KITCHENS. <br />FI ,] <br />SURFACE MOUNTED TOILET PAPER DISPENSER, MOUNT BOTTOM MIN 15" AFF TOP MAX 33" AFF <br />4 <br />LAVATORY; SINGLE LEVER 1 .5 GPM FAUCET AND CABINET <br />NOTE: ALL WINDOWS TO BE DOUBLE GLAZED VINYL FRAME W/ACCESSIBLE CONTROLS <br />WINDOWS W/.28 "U" FACTOR * .40 5HGC <br />I <br />5URFACE MOUNTED MIRROR WITH J-CLIP5 TO MATCH VANITY <br />tti <br />130" TOWEL BAR; PROVIDE SOLID BACKING IN WALL; MOUNT CENTER OF BAR <br />MAX. 4'-G" AFF. IN ALL UNITS MOUNT A PORTION OF TOWEL BARS @ 48" AFF <br />I FIBERGLASS TUB WITH PLASTIC LAMINATE SURROUND: TOP OF SURROUND <br />MINIMUM 72" ABOVE FLOOR; PROVIDE WITH BATH CURTAIN ROD <br />T (? SHOWER HEAD 1.75 GPM; MOUNT 4" ABOVE TOP OF SURROUND <br />I FURR WALL TO TUB ENCLOSURE; VERIFY DIMENSIONS <br />5' SHOWER (INSIDE CLEAR 36" X 60" MIN.) <br />ADA 5' ROLL -IN SHOWER WITH SEAT <br />SHOWER SPRAY UNIT 1.75 GPM, WITH A H05E AT LEAST GO" LONG, THAT CAN BE USED <br />AS A FIXED5HOWER HEAD OR AS A HAND HELD 5HOWER <br />GRAB BARS FOR ROLL -IN SHOWER <br />4 STACKED WA5HER/DRYER W/ VENT TO THE EXTERIOR (50 CFM), ENERGY STAR <br />�5 COMBINATION WA5HER/DPYER W/ VENT TO EXTERIOR (80 CFM), ENERGY STAR <br />I - 1 2" WIRE SHELF � POLE <br />9 5 - 12" WIRE SHELVES <br />VERIFY WALL TYPES A5 PER: RA 1. 1 5HEET <br />5TANDARD WALL (I HR)(SEE 5HT RA 1, 1 #3) <br />WINDOW INDICATOR <br />CORRIDOR WALL (5EE 5HT RA 1. 1 #4) <br />PLUMBING CORRIDOR WALL (SEE 5HT RA 1. 1 #4) <br />32c <br />DOOR INDICATOR <br />50FFITS, FOR DUCTS <br />UNIT PARTITION WALL (5EE 5HT RA I . 1 #5) <br />EXTERIOR WALL (5EE 5HT RA 1. 1 # 1) <br />DETAIL INDICATOR (SEE D 1. 5HT5) <br />2 HR WALL - GENERIC (5EE 5HT RA I. I ##ram) <br />INTERIOR ELEVATION5 (SEE 5HT AG. 1) <br />2 HP, WALL - (5TC 50) ($EE 5HT RA 1.2 #20) <br />2 HR EXTERIOR WALL (5EE 5HT RA 1 .2 # 1 9) <br />sA <br />5MOKE DETECTOR5 <br />@ <br />CARBON MONOXIDE DETECTOR <br />I HR 2 51DED EXTERIOP, WALL ON DECK <br />ME <br />uj <br />Lu <br />L, <br />Lu <br />HJ <br />Lu <br />Lu <br />STATES LICENSED: <br />WASHINGTON <br />ARIZONA <br />IDAHO <br />NEW MEXICO <br />MONTANA <br />WYOMING <br />CALIFORNIA <br />COLO ADO <br />NEVADA <br />NEBRASKA <br />UTAH <br />MISSOURI <br />ILLINOIS <br />INDIANA <br />1 BEDROOM III u[I T211 <br />91 Y SHEET <br />TYPICAL UNITS <br />SCALE 1 /4" = I '-Oil A2m3 <br />