My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5103 RUCKER AVE 2020 Plans 2022-12-01
>
Address Records
>
RUCKER AVE
>
5103
>
Plans
>
5103 RUCKER AVE 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:13:35 AM
Creation date
2/24/2022 8:50:20 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
5103
Permit
BW2004-002
Year
2020
Notes
SFR REMODEL TO PERMIT WORK DONE WITHOUT PERMITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />N, <br />N <br />BASEMENT FLOOR PLAN <br />1 . SCALE:1/4" = 1'-0" <br />I <br />CRAWL SPACE <br />I <br />CLOSET ' <br />NOTE <br />Ducts in the garage and ducts penetrating the walls or ceiling separating the <br />dwelling from the garage shall be constructed of a minimum No. 26 gauge ' <br />/ sheet steel or other approved material and shall not have openings into the <br />garage. <br />Appliances having an ignition source shall be elevated such that the source of <br />ignition is not less than 18 inches above the floor in garages Exception: <br />>SD Clothes dryers and appliances that are listed as flammable vapor ignition. <br />resistant. <br />All gas appliances installed in areas where they may be subjected to <br />mechanical damage shall be suitably guarded against such damage by being <br />installed behind adequate barriers or by being elevated or located out of the <br />DEN normal path of vehicles. <br />I' 1 <br />All walls and the ceiling that were covered without inspections will need to be I <br />exposed as required by the inspectors for inspection. <br />� 1 <br />:,k I <br />I <br />4 <br />_ - - - _ - -- - _ _ - - - - - - - - - - - _ - <br />I <br />WINDOW NOTES <br />ALL WINDOW SHALL COMPLY WITH 2O15 WASHINGTON STATE ENERGY CODE, PRESCRIPTIVE PATH PER SECTION R402.3 <br />ALL WINDOW SHALL BE NFRC RATED <br />OPERABLE WINDOWS WITHIN 10' OF GRADE SHALL BE CAPABLE OF LOCKING. <br />ALL EGRESS WINDOW SHALL PROVIDE A MIN. OF 5.7 SF OF AREA; MIN. NET CLEAR OPENING 20" WIDE AND MIN. 24" HIGH; MAX. SILL OF 44" AT FINISH <br />FLOOR. <br />PROVIDE SAFETY GLAZING NEAR WET SURFACE PER R308.4.5 <br />WINDOW MANUFACTURERAND CONTRACTOR TO VERIFYAND PROVIDE AN OVERALL ROUGH OPENING OF 1/2" OR GREATER THAN FRAME DIMENSION <br />IN THE HORIZONTAL, AND 3/4" GREATER THAN THE FRAME DIMENSION IN THE VERTICAL TO ALLOW FOR ADDITIONAL 1/4" WATERPROOFING AT SILL. <br />ALL OPERABLE WINDOW SHALL BE PROVIDED WITH SCREENS. <br />ALL ROUGH OPENINGS SHALL BE PROVIDED WITH SELF -HEALING MEMBRANE FLASHING AT ALL SIDES. <br />ALL ROUGH OPENINGS TO HAVE CAP FLASHING AT HEAD, AND PAN SILL. <br />PROVIDE A LEAST (1) ADJUSTABLE, INTEGRAL FRESH AIR INLET TRICKLE VENT, MIN. 4 SQ. IN. IN AREA, FOR EACH HABITABLE ROOM. <br />FLOOR PLAN NOTES <br />IALER <br />ALL DIMENSIONS ARE FACE OF FRAMING, CENTER OF COLUMN, <br />D E CS 1 t 7 N L L C <br />OR FACE OF CONCRETE, U.N.O. <br />-- <br />RES I DENTIAL-CO M M ERCIAL <br />CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & <br />CONDITIONS PRIOR TO CONSTRUCTION <br />16008 MOTOR PLACE <br />ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS <br />LY N N W O O D, WA 980137 <br />CELL:425-877-7377 <br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS <br />EMAIL: SiALEROES113N@r.MAiL.COM <br />WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES <br />DOOR JAMB 4" OFFSET FROM ADJACENT WALL, U.N.O. <br />.. , <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE <br />A <br />TREATED. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE <br />PRESSURE TREATED <br />SMOKE & CARBON MONOXIDE DETECTOR. <br />THESE DRAWINGS ARE COPYRIGHTED AND MAY <br />*SHALL BE 110V INTERCONNECTED W/ BATTERY <br />NOT BE COPIED OR REDRAWN WITHOUT THE <br />BACKUP. <br />WRITTEN PERMISSION OF SIALER DESIGN LLC. <br />USE OF THIS DRAWING IS LIMITED TO A SPECIFIC <br />*SHALL SOUND AN ALARM AUDIBLE IN ALL BEDROOMS. <br />PROTECT FOR s NAMED HEREON AND <br />FOR THE CONSTTRUCTIRUCTI ON OF ONE BUILDING. ANY <br />*SHALL BE INSTALLED ON EACH FLOOR AND IN ALL <br />OTHER USE OR REUSE IS STRICTLY PROHIBITED <br />BEDROOMS. <br />WITHOUT THE. WRITTEN CONSENT FROM SIALER <br />DESIGN LLC. <br />*SHALL BE INSTALLED IN EACH LOCATION WHERE <br />THERE IS A <br />COPYRIGHT 2020 <br />CEILING CHANGE OF GREATER THAN 24" <br />SIALER DESIGN LLC <br />ALL STORAGE & SPACES UNDER STAIRS TO BE FINISHED WITH / <br />REVISIONS <br />1/2" G.W.B. <br />DATE DESCRIPTION <br />DOOR BETWEEN HOUSE AND GARAGE SHALL BE SOLID CORE <br />WOOD, SOLID OR HONEYCOMB STEEL DOOR, NOT LESS THAN <br />1-3/8" THICKNESS. <br />ALL TILE SHOWER / BATH WALL TO BE SHEATHED WITH FULL <br />HEIGHT CONCRETE BACKER BOARD. ALL KITCHEN AND BATH <br />GWB TO BE WATER RESISTANT TO CEILING. <br />PROJECT: <br />ROJECT : <br />PROVIDE HANGING ROD & SHELF IN EACH CLOSET AS SHOWN <br />ON PLANS, TYR <br />FETTIG RESIDENCE <br />REMODEL <br />ALL WINDOW AND DOOR HEADER SHALL BE INSULATED WITH <br />MINIMUM OF R-10 RIGID INSULATION <br />5103 RUCKER AVE <br />LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY <br />EVERETT WA 98203 <br />C� <br />VISIBLE AND LEGIBLE FROM THE STREET <br />ENERGY CODE COMPLIANCE <br />CLIENT: <br />FETTIG SHAWN AND <br />ENERGY CREDIT TABLE R406.2: OPTION 5a FOR 0.5 CREDITS <br />N I KOLASH I N PAVEL <br />FREASH AIR PROVIDED BY WHOLE -HOUSE FAN WITH FRESH AIR <br />5103 RUCKER AVE <br />PORT (NET 4 SF IN MIN. OPENING) AT EACH HABITABLE ROOM. A <br />TIMER OPERATES AN EXHAUST FAN WHICH PULLS OUTSIDE AIR <br />EVERETT WA 98203 <br />THROUGH AIR INLETS LOCATED IN EACH HABITABLE ROOM. <br />ALL NEW WINDOW AND NEW GLASS DOORS MUST HAVE U- <br />SHEET NAME: <br />FACTOR = 0.30 OR BETTER <br />A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN <br />PROPOSED <br />LIGHTING FIXTURE SHALL BE HIGH-'-'T LAMPS. <br />C4 6 V/ <br />ALL SHOWER -HEAD AND KITCHEN SINK FAUCETS INSTALLED IN <br />BASEMENT <br />THE HOUSE SHALL BE RATED AT 1.75 GMP OR LESS. ALL <br />OTHERS LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR <br />LESS. <br />FLOOR PLAN <br />HOUSE VENTILATION <br />2015 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE <br />HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE 1507.3.3(1) & TABLE <br />1507.3.3(2), PROVIDE CONTROLS PER 1507.3.2 COMPLY WITH WSEC R403.6 <br />SYMBOL <br />LOCATION <br />MINIMUM FAN REQUIREMENTS <br />A <br />Bath & Powder <br />Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />Kitchen <br />Min. 400 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />B <br />(Make up air required) <br />Laundry <br />Min. 180 cfm (INTERMITTENT) @ .025" wg -to function and be <br />�C <br />labeled as whole house fan (4-5 bedrooms 3001 <4500 SF). <br />��� <br />To operate 33% of every four hour period <br />Habitable <br />Fresh air diffuser; Min. 90 cfm (CONTINUOUS) (4-5 BEDROOM <br />Spaces <br />3001 <4,500 SF). All ductwork in heat recovery system shall be <br />sized and installed per the manufacturer's instructions. <br />DRYER VENT PER (TABLE M1507.4) VENTED TO OUTSIDE <br />ALL FANS TO VENT TO OUTSIDE <br />APPROVED <br />PROJECT NUMBER: 2020-112 <br />DATE: 04/01 /2020 <br />CHECKED: LS <br />DRAWN: LS <br />STATUS: BUILDING PERMIT SET <br />A2m5 <br />PLOT SCALE: 1:1 PLOTTED ON:6/29/20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.