Laserfiche WebLink
i <br />N, <br />N <br />BASEMENT FLOOR PLAN <br />1 . SCALE:1/4" = 1'-0" <br />I <br />CRAWL SPACE <br />I <br />CLOSET ' <br />NOTE <br />Ducts in the garage and ducts penetrating the walls or ceiling separating the <br />dwelling from the garage shall be constructed of a minimum No. 26 gauge ' <br />/ sheet steel or other approved material and shall not have openings into the <br />garage. <br />Appliances having an ignition source shall be elevated such that the source of <br />ignition is not less than 18 inches above the floor in garages Exception: <br />>SD Clothes dryers and appliances that are listed as flammable vapor ignition. <br />resistant. <br />All gas appliances installed in areas where they may be subjected to <br />mechanical damage shall be suitably guarded against such damage by being <br />installed behind adequate barriers or by being elevated or located out of the <br />DEN normal path of vehicles. <br />I' 1 <br />All walls and the ceiling that were covered without inspections will need to be I <br />exposed as required by the inspectors for inspection. <br />� 1 <br />:,k I <br />I <br />4 <br />_ - - - _ - -- - _ _ - - - - - - - - - - - _ - <br />I <br />WINDOW NOTES <br />ALL WINDOW SHALL COMPLY WITH 2O15 WASHINGTON STATE ENERGY CODE, PRESCRIPTIVE PATH PER SECTION R402.3 <br />ALL WINDOW SHALL BE NFRC RATED <br />OPERABLE WINDOWS WITHIN 10' OF GRADE SHALL BE CAPABLE OF LOCKING. <br />ALL EGRESS WINDOW SHALL PROVIDE A MIN. OF 5.7 SF OF AREA; MIN. NET CLEAR OPENING 20" WIDE AND MIN. 24" HIGH; MAX. SILL OF 44" AT FINISH <br />FLOOR. <br />PROVIDE SAFETY GLAZING NEAR WET SURFACE PER R308.4.5 <br />WINDOW MANUFACTURERAND CONTRACTOR TO VERIFYAND PROVIDE AN OVERALL ROUGH OPENING OF 1/2" OR GREATER THAN FRAME DIMENSION <br />IN THE HORIZONTAL, AND 3/4" GREATER THAN THE FRAME DIMENSION IN THE VERTICAL TO ALLOW FOR ADDITIONAL 1/4" WATERPROOFING AT SILL. <br />ALL OPERABLE WINDOW SHALL BE PROVIDED WITH SCREENS. <br />ALL ROUGH OPENINGS SHALL BE PROVIDED WITH SELF -HEALING MEMBRANE FLASHING AT ALL SIDES. <br />ALL ROUGH OPENINGS TO HAVE CAP FLASHING AT HEAD, AND PAN SILL. <br />PROVIDE A LEAST (1) ADJUSTABLE, INTEGRAL FRESH AIR INLET TRICKLE VENT, MIN. 4 SQ. IN. IN AREA, FOR EACH HABITABLE ROOM. <br />FLOOR PLAN NOTES <br />IALER <br />ALL DIMENSIONS ARE FACE OF FRAMING, CENTER OF COLUMN, <br />D E CS 1 t 7 N L L C <br />OR FACE OF CONCRETE, U.N.O. <br />-- <br />RES I DENTIAL-CO M M ERCIAL <br />CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & <br />CONDITIONS PRIOR TO CONSTRUCTION <br />16008 MOTOR PLACE <br />ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS <br />LY N N W O O D, WA 980137 <br />CELL:425-877-7377 <br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS <br />EMAIL: SiALEROES113N@r.MAiL.COM <br />WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES <br />DOOR JAMB 4" OFFSET FROM ADJACENT WALL, U.N.O. <br />.. , <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE <br />A <br />TREATED. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE <br />PRESSURE TREATED <br />SMOKE & CARBON MONOXIDE DETECTOR. <br />THESE DRAWINGS ARE COPYRIGHTED AND MAY <br />*SHALL BE 110V INTERCONNECTED W/ BATTERY <br />NOT BE COPIED OR REDRAWN WITHOUT THE <br />BACKUP. <br />WRITTEN PERMISSION OF SIALER DESIGN LLC. <br />USE OF THIS DRAWING IS LIMITED TO A SPECIFIC <br />*SHALL SOUND AN ALARM AUDIBLE IN ALL BEDROOMS. <br />PROTECT FOR s NAMED HEREON AND <br />FOR THE CONSTTRUCTIRUCTI ON OF ONE BUILDING. ANY <br />*SHALL BE INSTALLED ON EACH FLOOR AND IN ALL <br />OTHER USE OR REUSE IS STRICTLY PROHIBITED <br />BEDROOMS. <br />WITHOUT THE. WRITTEN CONSENT FROM SIALER <br />DESIGN LLC. <br />*SHALL BE INSTALLED IN EACH LOCATION WHERE <br />THERE IS A <br />COPYRIGHT 2020 <br />CEILING CHANGE OF GREATER THAN 24" <br />SIALER DESIGN LLC <br />ALL STORAGE & SPACES UNDER STAIRS TO BE FINISHED WITH / <br />REVISIONS <br />1/2" G.W.B. <br />DATE DESCRIPTION <br />DOOR BETWEEN HOUSE AND GARAGE SHALL BE SOLID CORE <br />WOOD, SOLID OR HONEYCOMB STEEL DOOR, NOT LESS THAN <br />1-3/8" THICKNESS. <br />ALL TILE SHOWER / BATH WALL TO BE SHEATHED WITH FULL <br />HEIGHT CONCRETE BACKER BOARD. ALL KITCHEN AND BATH <br />GWB TO BE WATER RESISTANT TO CEILING. <br />PROJECT: <br />ROJECT : <br />PROVIDE HANGING ROD & SHELF IN EACH CLOSET AS SHOWN <br />ON PLANS, TYR <br />FETTIG RESIDENCE <br />REMODEL <br />ALL WINDOW AND DOOR HEADER SHALL BE INSULATED WITH <br />MINIMUM OF R-10 RIGID INSULATION <br />5103 RUCKER AVE <br />LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY <br />EVERETT WA 98203 <br />C� <br />VISIBLE AND LEGIBLE FROM THE STREET <br />ENERGY CODE COMPLIANCE <br />CLIENT: <br />FETTIG SHAWN AND <br />ENERGY CREDIT TABLE R406.2: OPTION 5a FOR 0.5 CREDITS <br />N I KOLASH I N PAVEL <br />FREASH AIR PROVIDED BY WHOLE -HOUSE FAN WITH FRESH AIR <br />5103 RUCKER AVE <br />PORT (NET 4 SF IN MIN. OPENING) AT EACH HABITABLE ROOM. A <br />TIMER OPERATES AN EXHAUST FAN WHICH PULLS OUTSIDE AIR <br />EVERETT WA 98203 <br />THROUGH AIR INLETS LOCATED IN EACH HABITABLE ROOM. <br />ALL NEW WINDOW AND NEW GLASS DOORS MUST HAVE U- <br />SHEET NAME: <br />FACTOR = 0.30 OR BETTER <br />A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN <br />PROPOSED <br />LIGHTING FIXTURE SHALL BE HIGH-'-'T LAMPS. <br />C4 6 V/ <br />ALL SHOWER -HEAD AND KITCHEN SINK FAUCETS INSTALLED IN <br />BASEMENT <br />THE HOUSE SHALL BE RATED AT 1.75 GMP OR LESS. ALL <br />OTHERS LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR <br />LESS. <br />FLOOR PLAN <br />HOUSE VENTILATION <br />2015 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE <br />HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE 1507.3.3(1) & TABLE <br />1507.3.3(2), PROVIDE CONTROLS PER 1507.3.2 COMPLY WITH WSEC R403.6 <br />SYMBOL <br />LOCATION <br />MINIMUM FAN REQUIREMENTS <br />A <br />Bath & Powder <br />Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />Kitchen <br />Min. 400 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />B <br />(Make up air required) <br />Laundry <br />Min. 180 cfm (INTERMITTENT) @ .025" wg -to function and be <br />�C <br />labeled as whole house fan (4-5 bedrooms 3001 <4500 SF). <br />��� <br />To operate 33% of every four hour period <br />Habitable <br />Fresh air diffuser; Min. 90 cfm (CONTINUOUS) (4-5 BEDROOM <br />Spaces <br />3001 <4,500 SF). All ductwork in heat recovery system shall be <br />sized and installed per the manufacturer's instructions. <br />DRYER VENT PER (TABLE M1507.4) VENTED TO OUTSIDE <br />ALL FANS TO VENT TO OUTSIDE <br />APPROVED <br />PROJECT NUMBER: 2020-112 <br />DATE: 04/01 /2020 <br />CHECKED: LS <br />DRAWN: LS <br />STATUS: BUILDING PERMIT SET <br />A2m5 <br />PLOT SCALE: 1:1 PLOTTED ON:6/29/20 <br />