5103 RUCKER AVE 2020 Plans 2022-12-01
>
Address Records
>
RUCKER AVE
>
5103
>
Plans
>
5103 RUCKER AVE 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:13:35 AM
Creation date
2/24/2022 8:50:20 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
5103
Permit
BW2004-002
Year
2020
Notes
SFR REMODEL TO PERMIT WORK DONE WITHOUT PERMITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />! <br />i <br />ALL WINDOW SHALL COMPLY WITH 2O15 WASHINGTON STATE ENERGY CODE, PRESCRIPTIVE PATH PER SECTION R402.3 <br />ALL WINDOW SHALL BE NFRC RATED <br />OPERABLE WINDOWS WITHIN 10° OF GRADE SHALL BE CAPABLE OF LOCKING. <br />ALL EGRESS WINDOW SHALL PROVIDE A MIN. OF 5.7 SF OF AREA; MIN. NET CLEAR OPENING 20°" WIDE AND MIN, 24" HIGH; MAX. SILL OF 44" AT FINISH <br />FLOOR. <br />PROVIDE SAFETY GLAZING NEAR WET SURFACE PER R303.4.5 <br />WINDOW MANUFACTURER AND CONTRACTOR TO VERIFYAND PROVIDE AN OVERALL ROUGH OPENING OF 1/2" OR GREATER THAN FRAME DIMENSION <br />IN THE HORIZONTAL, AND 3/4" GREATER THAN THE FRAME DIMENSION IN THE VERTICAL TO ALLOW FOR ADDITIONAL 1/4" WATERPROOFING AT SILL. <br />ALL OPERABLE WINDOW SHALL BE PROVIDED WITH SCREENS. <br />ALL ROUGH OPENINGS SHALL BE PROVIDED WITH SELF -HEALING MEMBRANE FLASHING AT ALL SIDES. <br />ALL ROUGH OPENINGS TO HAVE CAP FLASHING AT HEAD, AND PAN SILL. <br />PROVIDE A LEAST (1) ADJUSTABLE, INTEGRAL FRESH AIR INLET TRICKLE VENT, MINI. 4 SQ. IN. IN AREA, FOR EACH HABITABLE ROOM. <br />ALL DIMENSIONS ARE FACE OF FRAIIVIi ZING, CENTER OF COLUMN, <br />OR FACIE OF CONCRETE, U.N.O. <br />CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS <br />CONDITIONS PRIOR TO CONSTRUCTION <br />ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS <br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS <br />WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES <br />DOOR JAMB 4" OFFSET FROM ADJACENT WALL, U.N.O. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE <br />TREATED. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE <br />PRESSURE TREATED <br />SMOKE &z CARBON MONOXIDE DETECTOR. <br />*SHALL BE 110V INTERCONNECTED W1 BATTERY <br />BACKUP, <br />*SHALL SOUND AN ALARM AUDIBLE IN ALL BEDROOMS. <br />*SHALL BE INSTALLED ON EACH FLOOR AND IN ALL <br />BEDROOMS. <br />*SHALL BE INSTALLED IN EACH LOCATION WHERE <br />THERE IS A CEILING CHANGE OF GREATER THAN 24°" <br />ALL STORAGE & SPACES UNDER STAIRS TO BE FINISHED WITH / <br />1/2" G.W.B. <br />DOOR BETWEEN HOUSE AND GARAGE SHALL BE SOLID CORE <br />WOOD, SOLID OR HONEYCOMB STEEL DOOR, NOT LESS THAN <br />1-3/3" THICKNESS. <br />ALL TILE SHOWER / BATH WALL TO BE SHEATHED WITH FULL <br />HEIGHT CONCRETE BACKER BOARD. ALL KITCHEN AND BATH <br />GWB TO BE WATER RESISTANT TO CEILING, <br />PROVIDE HANGING ROD &s SHELF IN EACH CLOSET AS SHOWN <br />ON PLANS, TYP. <br />ALL WINDOW AND DOOR HEADER SHALL BE INSULATED WITH A <br />MINIMUM OF R-10 RIGID INSULATION <br />LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY <br />VISIBLE AND LEGIBLE FROM THE STREET <br />ENERGY CODE COMPLIANCE <br />ENERGY CREDIT TABLE R406.2: OPTION 5a FOR 0.5 CREDITS <br />FREASH AIR PROVIDED BY WHOLE -HOUSE FAN WITH FRESH AIR <br />PORT (NET 4 SF IN MIN. OPENING) AT EACH HABITABLE ROOM. A <br />TIMER OPERATES AN EXHAUST FAN WHICH PULLS OUTSIDE AIR <br />THROUGH AIR INLETS LOCATED IN EACH HABITABLE ROOM. <br />ALL NEW WINDOW AND NEW <br />! = 030 OR BETTER <br />SHOWER-HEADALL AND KITCHEN SINK FAUCETS INSTALLED IN <br />i. HOUSE SHALL ,, RATED <br />I. Ii OR <br />ALL <br />OTHERS d.TORY FAUCETS SHALL BE RATED GPM OIL <br />.. -ia, (�, ��in <br />VENTILATIONHOUSE I,. EXHAUST PER 1507.3 TABLEfin.. <br />1507.3.3(2),PROVIDE PER1507.3.2 COMPLY WITHR403.6 <br />SYMBOL <br />LOCATION <br />MINIMUM FAN REQUIREMENTS <br />*A— <br />Bath & Powder <br />Min. 50 cfrn (INTERMITTENT) @ .025"° WG (TABLE M1507.4) <br />Kitchen <br />Min. 400 cfrn (INTERMITTENT) @ .025" WG (TABLE M1507A) <br />(Male up air required) <br />Laundry <br />Min. 130 cfm (INTERMITTENT) @ .025" wg -to function and 5e <br />-*C <br />labeled as whole house fan (4-5 bedrooms 3001<4500 SF). <br />To operate 33% of every four hour period <br />Habitable <br />Fresh air diffuser; Min. 00 cfrn (CONTINUOUS) (4-5 BEDROOM <br />Spaces <br />3001<4,500 SF). All ductwork In heat recovery system shall be <br />sized and installed per the manufacturer's instructions. <br />DRYER VENT PER (TABLE M1507.4) VENTED TO OUTSIDE <br />ALL FANS TO VENT TO OUTSIDE <br />S I A i::.'��a'aiwm7 E P <br />DES � N LLC <br />RESIDENTIAL.-E0M M ERCIAL_ <br />1 600B IM0TOP, PLACE <br />LN'I\INV0 OOD, WA 90007 <br />CIELL:400-070-737 7 <br />ENBA, L: a ALERDES813N@OMAA L.o©i�li <br />DATE DESCRIPTION <br />PROJECT: <br />FETTIG RESIDENCE <br />CLIENT <br />FETT�.. SHAWN <br />d <br />ER AVE <br />I _.. EI WA 98203 <br />SHEET NAME: <br />APPROVED <br />BUILDING PERMIT <br />PLOT SCALE: 1:1 PLOTTED ON:6/29/20 <br />