3430 NORTON AVE 2021 Plans 2023-01-26
>
Address Records
>
NORTON AVE
>
3430
>
Plans
>
3430 NORTON AVE 2021 Plans 2023-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 10:38:13 AM
Creation date
2/25/2022 7:40:33 AM
Metadata
Fields
Template:
Address Document
Street Name
NORTON AVE
Street Number
3430
Permit
B2107-048
Year
2021
Notes
CONSTRUCT ACCESSORY DWELLING UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING CODE <br />2016 INTERNATIONAL BUILDING CODE <br />FLOOR LOAD <br />DEAD LOAD 12 psf <br />LIVE LOAD: 40 psf <br />ROOF LOAD <br />DEAD LOAD: 15 psf <br />FLAT ROOF SNOW LOAD: 25 psf <br />SNOW EXPOSURE FACTOR (Ce): 1.1 <br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.1 <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (1w): 1.0 <br />BUILDING CATEGORY: II <br />3. WIND EXPOSURE: B <br />4. Kzt = 1.37 <br />5. INTERNAL PRESSURE COEFFICIENT: NA <br />6. APPLICABLE WIND PRESSURE FOR <br />COMPONENTS AND CLADDING: NA <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: 1.0 <br />SEISMIC USE GROUP: 1 <br />2. SPECTRAL RESPONSE ACCELERATION (Ss): 133.3% G <br />3. SITE CLASS: D (ASSUMED) <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 88.9%G <br />5. SEISMIC DESIGN CATEGORY: D <br />6. BASIC SEISMIC -FORCE -RESISTING SYSTEM: SHEARWALLS <br />7. DESIGN BASE SHEAR: SEE CALCULATIONS <br />8. SEISMIC RESPONSE COEFFICIENT (Cs): 0.137 <br />9. RESPONSE MODIFICATION FACTOR (R): 6.5 <br />10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL <br />FORCE PROCEDURE <br />FOUNDATIONS <br />1. THE FOUNDATION DESIGN IS BASED ON THE <br />RECOMMENDATION IN THE INTERNATIONAL BUILDING CODE <br />TABLE 1804.2. FOUNDATION WORK SHALL BE PERFORMED <br />IN ACCORDANCE WITH CHAPTER 18 OF THIS CODE. <br />2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING <br />VALUES: <br />ALLOW. SOIL BEARING = 1500 PSF <br />SOIL FRICTION = .25 <br />EQUIV. FLUID PRESSURES: <br />*ACTIVE PRESSURE = 35 PCF <br />PASSIVE PRESSURE = 150 PCF <br />*(WALLS RESTRAINED AGAINST ROTATION SHALL BE <br />DESIGNED FOR AN EQUIV. FLUID PRESSURE OF 55 <br />PCF). <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW <br />THE UNDISTURBED GROUND SURFACE OR TO FROST DEPTH. <br />ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR <br />UNDISTURBED NATURAL GRADE UNLESS OTHERWISE NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING <br />SHALL CONSIST OF THE EXCAVATED MATERIAL AND/OR <br />IMPORTED BORROW AND SHALL BE FREE OF ORGANIC <br />MATTER, TRASH, LUMBER, OR OTHER DEBRIS. ALL WALLS <br />SHALL BE ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL <br />AND BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO <br />EXCEED 8 INCHES THICK, PROPERLY MOISTENED TO <br />APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY <br />ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN <br />SUCH A MANNER AND EXTENT AS TO PRODUCE A RELATIVE <br />COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY AS <br />DETERMINED BY ASTM D1557. HAND TAMPERS SHALL WEIGH <br />AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE <br />AREA NOT IN EXCESS OF 64 SQUARE INCHES. HAND <br />TAMPERS MAY BE OPERATED EITHER MANUALLY OR <br />MECHANICALLY AND SHALL BE USED WHERE LARGER POWER <br />DRIVEN COMPACTION EQUIPMENT CANNOT BE USED. FILL <br />OVER 12" DEEP SHALL COMPLY WITH A GEOTECHNICAL <br />REPORT. <br />FRAMING LUMBER <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND <br />HEADERS; HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2 FOR <br />ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON <br />PLANS). LUMBER TO BE GRADE MARKED PER WCLIB SPECIFICATIONS. <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, EXPOSURE 1 SHEATHING <br />CONFORMING TO EITHER COMMERCIAL STANDARDS DOC PS 1 OR PS 2. PROVIDE MINIMUM <br />OF 3/8" EDGE DISTANCE ON ALL NAILS AND A 1 /8" EXPANSION JOINT BETWEEN ALL <br />PANEL EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: <br />REINFORCING STEEL <br />1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 <br />GRADE 60 (fy = 60 KSI) FOR BAR SIZES NO. 5 & LARGER, <br />GRADE 40 (fy = 40 KSI) FOR NO. 3 AND NO. 4 BARS. <br />2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON <br />THE PLANS. WHERE LAP OR SPLICE LOCATIONS ARE NOT <br />SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, <br />LAPS AND/OR SPLICES SHALL BE 42 TIMES BAR DIA AND <br />BE WELL STAGGERED. <br />ROOF SHEATHING TO BE 15/32" C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, 3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED <br />P.I. 24/16 (USE 5-PLY FOR PANELIZED ROOFS). NAIL WITH 8d NAILS AT 6" ON CENTER IN ACCORDANCE WITH ACI 315 SHALL BE REVIEWED BY THE <br />AT PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED ENGINEER AND AVAILABLE ON THE JOB SITE PRIOR TO THE <br />OTHERWISE. PLACING OF CONCRETE. <br />SUB FLOORING TO BE 3/4" T&G C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, <br />P.I. 48/24. GLUE AND NAIL WITH 10d NAILS AT 6" ON CENTER AT PANEL EDGES AND <br />12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. <br />3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE <br />UNLESS NOTED OTHERWISE. USE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED <br />OR APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />5. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS UNLESS <br />SPECIFICALLY NOTED OTHERWISE. USE SOLID BLOCKING UNDER PARTITIONS <br />PERPENDICULAR TO JOISTS. <br />6. RIM JOIST ARE 11 /4" LSL OR 2x SOLID SAWN LUMBER AS MINIMUM. <br />7. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL <br />MEMBERS. <br />8. PROVIDE 2X2 WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS <br />BEARING ON WOOD. <br />9. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS OTHERWISE <br />NOTED. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL <br />DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED. <br />10. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" MINIMUM <br />DIAMETER BOLTS SPACED AT 48" O.C. MAXIMUM SPACING (EMBED 7" MINIMUM INTO <br />CONCRETE OR MASONRY). SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS WHERE <br />OCCUR. <br />11. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION). ALL FOUNDATION <br />BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZEDED, OR Z-MAX COATING TO <br />PROTECT FROM OXIDATION. <br />12. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVELY <br />TREATED WOOD SHALL BE RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. IRC <br />320.3.1 <br />13. 2X4 RAFTERS EXCEPT WHERE SPECIFICALLY DETAILED SHALL NOT SUPPORT <br />SUSPENDED CEILINGS, SPRINKLERS, DROP SOFFITS, OR ANY OTHER ELEMENTS. <br />14. WIRE STAPLES MAY BE SUBSTITUTED FOR DIAPHRAGM AND SHEARWALL NAILING <br />WHEN APPROVED BY THE STRUCTURAL ENGINEER. <br />15. EXTERIOR STUD WALLS SHALL BE 2X6 @ 16" O.C.. UNLESS NOTED OTHERWISE. <br />INTERIOR STUD BEARING WALLS SHALL BE CONSTRUCTED USING 2X4 @ 16" O.C. AT <br />UPPER TWO FLOORS AND EITHER 2X6 @ 16" O.C. OR 3X4 @ 16" O.C. BELOW TOP TWO <br />FLOORS. STUD NONBEARING WALLS SHALL BE CONSTRUCTED USING 2X4 @ 24" O.C.. <br />UNLESS NOTED OTHERWISE. SEE NOTE 1 FOR LUMBER GRADES OF STUDS AND PLATES. <br />16. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR <br />APPROVED EQUAL. APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION. <br />FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND <br />QUANTITIES AS SPECIFIED BY THE MANUFACTURER. <br />17. ALL HEADERS SHALL BE 4X8 DF#2 UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />18. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR PLYWOOD USED <br />IN SHEAR PANELS. <br />19. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND <br />NOTES. <br />4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND <br />A185 AND SHALL BE 6x6 W2.1 /W2.1 UNLESS OTHERWISE <br />NOTED. LAP REINFORCEMENT 6" MINIMUM. <br />5. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS <br />SHALL BE SECURELY TIED IN PLACE BEFORE CONCRETE IS <br />POURED. SLAB ON GRADE REINFORCEMENT SHALL BE <br />PLACED AT MID -DEPTH OF SLAB AND SHALL BE HELD <br />SECURELY IN PLACE WITH MECHANICAL DEVICES DURING <br />PLACING OF THE CONCRETE. <br />6. REINFORCEMENT SHALL PLACED CONTINUOUS AROUND <br />CORNERS AND INTERSECTIONS UNLESS SPECIFIED OTHERWISE. <br />7. WELDED REINFORCING STEEL SHALL CONFORM TO ASTM <br />A706 GRADE 600 WITH A CARBON EQUIVALENT NOT <br />EXCEEDING 0.55%. THE BAR SHALL DEMARCATED AS <br />'WELDABLE' (W). ALL WELDS SHALL FULLY DEVELOP THE <br />REINFORCING STEEL YIELD STRENGTH UNLESS NOTED <br />OTHERWISE. ALL REINFORCING STEEL WELDING SHALL BE <br />CONDUCTED PER AWS D1.4 BY A WABO CERTIFIED WELDER. <br />WELDED PERPENDICULAR REINFORCING STEEL SHALL <br />CONFORM TO ASTM A184. ALL FIELD WELDING REQUIRES <br />SPECIAL INSPECTION. <br />Q� <br />o <br />� <br />N <br />Ln <br />N <br />Lo <br />o <br />> <br />C) <br />Q <br />N <br />U <br />� <br />G) <br />Q <br />� <br />_ <br />(S) <br />� <br />M <br />L <br />O <br />_ <br />m <br />W <br />� <br />N <br />� <br />W <br />L <br />O <br />co vt <br />of WAS,y�c� <br />� c � <br />1 <br />f 343 <br />ffm <br />Drawn Dy: VKY <br />Checked By: CN RI5 <br />Date:09-1 1-2020 <br />5DA JOD NO. <br />9055 <br />T JTR.UCTURAL. <br />T <br />REVIEWEDFOR PERMIT NOTES <br />5-1.0 <br />