My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 E MARINE VIEW DR BUILDING J 2022-08-29
>
Address Records
>
E MARINE VIEW DR
>
1622
>
BUILDING J
>
1622 E MARINE VIEW DR BUILDING J 2022-08-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2022 10:41:38 AM
Creation date
2/28/2022 11:42:43 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1622
Tenant Name
BUILDING J
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Riverview 1 I WSEC Air Barrier Testing Report <br /> q avi4 . <br /> Test Equipment and Building Test Preparation Procedures <br /> Testing was conducted by deploying 6 high-capacity Retrotec 3000SR orifice blower door fans, installed in <br /> exterior entry doors. Below is an outline of the measures taken to ensure only legitimate leakage through the <br /> envelope was measured. <br /> -isolated bathroom and laundry exhausts <br /> -isolated range exhausts <br /> -isolated toilets, plugged bathroom and kitchen sinks with water or masking <br /> Upon successful installation of the fans, the building was pressurized sampling differential pressure in 5 Pa <br /> increments. Before and after each test, zero-flow baseline pressures were taken and used to correct the final <br /> pressure measurements. The resulting pressure and flow data points were then plotted to determine their <br /> correlation and identify the pressure exponent and leakage coefficient which are indicative of the building's <br /> leakage characteristics. <br /> Report Conclusion <br /> ASTM E779-15 testing performed by Soloveda indicates that the building enclosure air tightness capabilities <br /> meet or exceed the formal performance requirements set forth in 2015 WSEC Section C402.5.1.2. <br /> Congratulations on a successful test at Riverview Building J! <br /> Regards, <br /> o/na/A,a z 47ti a e7-.('kl i.)4 <br /> Operations Manager <br /> Soloveda Division II LLC <br /> 206.850.5950 <br /> Jonathan@Soloveda.com <br /> This report was prepared for Soloveda's client and contains findings,comments,and observations made by a qualified representative of Soloveda. The <br /> report is intended to serve as a Quality Assurance tool,and is provided in a timely manner so that remedial action can be undertaken as necessary. Note <br /> that the testing conducted was not inclusive of all specimens present and is therefore limited in nature. Accordingly,Soloveda's statements contained <br /> herein do not constitute approval,disapproval,certification,acceptance of performance of products materials,or endorsement by this laboratory/testing <br /> agency. The report is the exclusive property of our client,and relates solely to the specimens tested. <br /> Page 718 <br />
The URL can be used to link to this page
Your browser does not support the video tag.